National Instruments PXIe-4302 Скачать руководство пользователя страница 4

EtherCAT

®

 is a registered trademark of and licensed by Beckhoff Automation GmbH.

CANopen

®

 is a registered Community Trademark of CAN in Automation e.V.

DeviceNet

 and EtherNet/IP

 are trademarks of ODVA.

Go!, SensorDAQ, and Vernier are registered trademarks of Vernier Software & Technology. Vernier Software & Technology 

and 

vernier.com

 are trademarks or trade dress.

Xilinx is the registered trademark of Xilinx, Inc.
Taptite and Trilobular are registered trademarks of Research Engineering & Manufacturing Inc.
FireWire

®

 is the registered trademark of Apple Inc.

Linux

®

 is the registered trademark of Linus Torvalds in the U.S. and other countries.

Handle Graphics

®

, MATLAB

®

, Real-Time Workshop

®

, Simulink

®

, Stateflow

®

, and xPC TargetBox

®

 are registered 

trademarks, and TargetBox

 and Target Language Compiler

 are trademarks of The MathWorks, Inc.

Tektronix

®

, Tek, and Tektronix, Enabling Technology are registered trademarks of Tektronix, Inc.

The Bluetooth

®

 word mark is a registered trademark owned by the Bluetooth SIG, Inc.

The ExpressCard

 word mark and logos are owned by PCMCIA and any use of such marks by National Instruments is under 

license.
The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft 

Corporation in the United States and other countries.
Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments 

and have no agency, partnership, or joint-venture relationship with National Instruments.

Patents

For patents covering National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your 

software, the

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

.

Export Compliance Information

Refer to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for the National Instruments global 

trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

YOU ARE ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY AND 

RELIABILITY OF THE PRODUCTS WHENEVER THE PRODUCTS ARE INCORPORATED IN YOUR SYSTEM OR 

APPLICATION, INCLUDING THE APPROPRIATE DESIGN, PROCESS, AND SAFETY LEVEL OF SUCH SYSTEM 

OR APPLICATION.
PRODUCTS ARE NOT DESIGNED, MANUFACTURED, OR TESTED FOR USE IN LIFE OR SAFETY CRITICAL 

SYSTEMS, HAZARDOUS ENVIRONMENTS OR ANY OTHER ENVIRONMENTS REQUIRING FAIL-SAFE 

PERFORMANCE, INCLUDING IN THE OPERATION OF NUCLEAR FACILITIES; AIRCRAFT NAVIGATION; AIR 

TRAFFIC CONTROL SYSTEMS; LIFE SAVING OR LIFE SUSTAINING SYSTEMS OR SUCH OTHER MEDICAL 

DEVICES; OR ANY OTHER APPLICATION IN WHICH THE FAILURE OF THE PRODUCT OR SERVICE COULD 

LEAD TO DEATH, PERSONAL INJURY, SEVERE PROPERTY DAMAGE OR ENVIRONMENTAL HARM 

(COLLECTIVELY, “HIGH-RISK USES”). FURTHER, PRUDENT STEPS MUST BE TAKEN TO PROTECT AGAINST 

FAILURES, INCLUDING PROVIDING BACK-UP AND SHUT-DOWN MECHANISMS. NI EXPRESSLY DISCLAIMS 

ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS OR SERVICES FOR HIGH-RISK 

USES.

Содержание PXIe-4302

Страница 1: ...SC Express NI PXIe 4302 4303 User Manual 32 Ch 24 bit 5 kS s or 51 2 kS s Simultaneous Filtered Data Acquisition Module NI PXIe 4302 4303 User Manual August 2015 377003A 01...

Страница 2: ...mail addresses and current events National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin Texas 78759 3504 USA Tel 866 ASK MYNI 275 6964 For further support information refer t...

Страница 3: ...ESS FOR A PARTICULAR PURPOSE TITLE OR NON INFRINGEMENT AND ANY WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEALING NI DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING TH...

Страница 4: ...es independent from National Instruments and have no agency partnership or joint venture relationship with National Instruments Patents For patents covering National Instruments products technology re...

Страница 5: ...tions 2 8 NI PXIe 4302 4303 Block Diagram 2 8 Signal Acquisition Considerations 2 9 Nyquist Frequency and Nyquist Bandwidth 2 9 ADC 2 9 Operation Modes 2 9 Buffered Mode Acquisitions 2 10 Anti Alias F...

Страница 6: ...g Signal Source with Balanced Bias Resistors 2 3 Figure 2 4 Connecting AC Coupled Floating Sources with Low Impedance 2 3 Figure 2 5 Connecting AC Coupled Floating Sources with Balanced Bias Resistors...

Страница 7: ...d selectable digital filters to reject out of band noise Installation Refer to the NI PXIe 4302 4303 and TB 4302 4302C User Guide and Terminal Block Specifications document for step by step software a...

Страница 8: ...nnecting Voltage Signals Note The TB 4302 terminal block is required when measuring voltage signals Connecting Floating Signal Sources A floating signal source is not connected to the building ground...

Страница 9: ...ns yielding better rejection of coupled noise Since the bias resistor is between the negative line of the floating source and AIGND this configuration does not load down the floating source output Fig...

Страница 10: ...GND Figure 2 4 Connecting AC Coupled Floating Sources with Low Impedance If the source has high output impedance and is AC coupled balance the signal path as previously described with balanced bias re...

Страница 11: ...eferenced Signal Sources With this type of connection the NI PXIe 4302 4303 rejects both the common mode noise in the signal and the ground potential difference between the signal source and the devic...

Страница 12: ...a dedicated VSUP terminal to supply voltage to the transducer on each AI channel You can only connect one external voltage supply to the TB 4302C The TB 4302C internally shorts all of the negative AI...

Страница 13: ...s of each signal Refer to the NI PXIe 4302 4303 and TB 4302 4302C User Guide and Terminal Block Specifications for signal locations on the terminal blocks AI External Power Supply 2 A Max AISENSE AIGN...

Страница 14: ...AI8 AI9 24 AI10 AI11 AI11 23 AIGND AI12 AI13 22 AI14 AI12 AI13 21 AI14 AI15 AI15 20 AIGND AI16 AI17 19 AI18 AI16 AI17 18 AI18 AI19 AI19 17 AIGND AI20 AI21 16 AI22 AI20 AI21 15 AI22 AI23 AI23 14 AIGND...

Страница 15: ...teps before being sent to software Refer to the Timing Engines and DSP Streams section for more information about this digital block Table 2 2 I O Connector Signal Descriptions Signal Names Direction...

Страница 16: ...lves oversampling the input signal and then decimating and filtering the resulting data to achieve the desired sample rate The NI PXIe 4302 supports rates of 1 S s to 5 kS s The NI PXIe 4303 supports...

Страница 17: ...ics some of these components might be represented correctly while others contain aliased artifacts Lowpass filtering to eliminate components above the Nyquist frequency either before or during the dig...

Страница 18: ...gital filtering performed by the NI PXIe 4302 4303 produces a delay of many samples worth of time between when an event occurs on the input signal going into the NI PXIe 4302 4303 and when the data as...

Страница 19: ...supports Refer to Digital AI Filtering in the NI DAQmx Help for more information about how to configure the filter used Refer to the NI PXIe 4302 4303 Specifications for more information about the cu...

Страница 20: ...eness Checking document for more information To access this document go to ni com info and enter the Info Code daqhwtsp Hardware Timed Single Point Acquisition Model The HWTSP data path is optimized f...

Страница 21: ...to the process Figure 2 12 Typical Control System To successfully close a 2 kHz control loop make sure that the time between the time the AI sample is acquired and the time the AO stimulus is generate...

Страница 22: ...ore than 480 s will fail to close the 2 kHz control loop When analyzing the bandwidth of the system you must consider the group delay of all the components of the system When using only the NI PXIe 43...

Страница 23: ...tions The analog trigger signal can be used as a reference trigger only In a reference triggered acquisition you configure the module to acquire a certain number of pre trigger samples and a certain n...

Страница 24: ...nels and to eliminate clock drift between modules in long duration operations You can synchronize the analog input operations on two or more NI PXIe 4302 4303 modules to extend the channel count for y...

Страница 25: ...ve module tasks using the DAQmxTaskControl VI Function This sets them up to expect the sync pulse from the master 9 Commit the sync pulse master module task using the DAQmxTaskControl VI Function This...

Страница 26: ...of these types and each stream can handle up to 8 channels Therefore it is possible to use all 32 channels in either buffered mode or hardware timed single point mode AI Channels and DSP Streams Whil...

Страница 27: ...ingle point mode an error would still be produced by the second task since ai24 in the first task has forced ai24 ai31 to all be buffered mode channels Accessory Auto Detection SC Express modules auto...

Страница 28: ...ripheral slot in a PXI Express chassis PXIe_SYNC100 allows modules using PXIe_CLK100 as their reference to recreate the timing of the PXI_CLK10 signal while taking advantage of the lower skew of PXIe_...

Страница 29: ...slot of a PXI system but the system will not be able to use the Star Trigger feature PXIe_DSTAR A C PXI Express devices can provide high quality and high frequency point to point connections between...

Страница 30: ...libration services to help you maintain accuracy and minimize downtime over the life of your system Visit ni com services for more information Warranty and Repair All NI hardware features a one year s...

Страница 31: ...Membership The Standard Service Program SSP is a renewable one year subscription included with almost every NI software product including NI Developer Suite This program entitles members to direct acc...

Отзывы: