background image

Appendix B

Technical Support Resources

IMAQ PCI/PXI-1407 User Manual

B-2

www.ni.com

Software-Related Resources

Instrument Driver Network—A library with hundreds of instrument 
drivers for control of standalone instruments via GPIB, VXI, or serial 
interfaces. You also can submit a request for a particular instrument 
driver if it does not already appear in the library.

Example Programs Database—A database with numerous, 
non-shipping example programs for National Instruments 
programming environments. You can use them to complement the 
example programs that are already included with National Instruments 
products.

Software Library —A library with updates and patches to application 
software, links to the latest versions of driver software for National 
Instruments hardware products, and utility routines.

Worldwide Support

National Instruments has offices located around the globe. Many branch 
offices maintain a Web site to provide information on local services. You 
can access these Web sites from 

www.ni.com/worldwide

If you have trouble connecting to our Web site, please contact your local 
National Instruments office or the source from which you purchased your 
National Instruments product(s) to obtain support.

For telephone support in the United States, dial 512 795 8248. For 
telephone support outside the United States, contact your local branch 
office:

Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, 
Brazil 011 284 5011, Canada (Calgary) 403 274 9391, 
Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521, 
China 0755 3904939, Denmark 45 76 26 00, Finland 09 725 725 11, 
France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427, 
Hong Kong 2645 3186, India 91805275406, Israel 03 6120092, 
Italy 02 413091, Japan 03 5472 2970, Korea 02 596 7456, 
Mexico (D.F.) 5 280 7625, Mexico (Monterrey) 8 357 7695, 
Netherlands 0348 433466, Norway 32 27 73 00, Poland 48 22 528 94 06, 
Portugal 351 1 726 9011, Singapore 2265886, Spain 91 640 0085, 
Sweden 08 587 895 00, Switzerland 056 200 51 51, 
Taiwan 02 2377 1200, United Kingdom 01635 523545

Содержание PXI-1407

Страница 1: ...IMAQ IMAQ PCI PXI 1407 User Manual High Quality Monochrome Image Acquisition Boards for PCI PXI and CompactPCI Bus IMAQ PCI PXI 1407 User Manual October 1999 Edition Part Number 322156B 01...

Страница 2: ...4 24 24 Germany 089 741 31 30 Greece 30 1 42 96 427 Hong Kong 2645 3186 India 91805275406 Israel 03 6120092 Italy 02 413091 Japan 03 5472 2970 Korea 02 596 7456 Mexico D F 5 280 7625 Mexico Monterrey...

Страница 3: ...ailures caused by owner s failure to follow the National Instruments installation operation or maintenance instructions owner s modification of the product owner s abuse misuse or negligent acts and p...

Страница 4: ...interference to radio and television reception Classification requirements are the same for the Federal Communications Commission FCC and the Canadian Department of Communications DOC Changes or modif...

Страница 5: ...s Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada European Union Compliance to EEC Directives Readers in the EU EEC EEA must refer...

Страница 6: ...c software version This icon denotes a note which alerts you to important information This icon denotes a warning which advises you of precautions to take to avoid being electrically shocked italic It...

Страница 7: ...Get Started 2 1 Optional Equipment 2 2 How to Set up Your IMAQ System 2 2 Unpacking 2 4 Installation 2 4 Chapter 3 Hardware Overview Functional Overview 3 1 Video Buffer 3 2 Gain and Offset Circuitry...

Страница 8: ...es Figure 1 1 The Relationship between the Programming Environment NI IMAQ and Your Hardware 1 3 Figure 1 2 NI IMAQ Functions 1 4 Figure 1 3 IMAQ Vision Builder and Application Development Tools 1 5 F...

Страница 9: ...l the board and begin your image acquisition The PCI PXI 1407 ships with NI IMAQ the National Instruments complete image acquisition driver software you can use to directly control your board Using NI...

Страница 10: ...CI devices with sub buses and PXI The standard implementation for CompactPCI does not include these sub buses Your PXI 1407 device will work in any standard CompactPCI chassis adhering to the PICMG 2...

Страница 11: ...IMAQ and Your Hardware Vision Software IMAQ Vision Gauging and Measurement Pattern Matching Blob Analysis Image Analysis Morphology Display and ROI Color Matching and Analysis Filters Application Soft...

Страница 12: ...chapter NI IMAQ has both high level and low level functions for maximum flexibility and performance Examples of high level functions include the functions to acquire images in single shot or continuou...

Страница 13: ...ons without knowledge of any algorithm implementations IMAQ Vision is available for LabVIEW BridgeVIEW LabWindows CVI Microsoft Visual C or ComponentWorks IMAQ Vision Builder IMAQ Vision Builder is an...

Страница 14: ...nal Instruments IMAQ hardware and IMAQ Vision pattern matching software you can quickly and accurately locate objects in instances where objects vary in size orientation focus and even when the part i...

Страница 15: ...e following One of the following 1407 devices PCI 1407 PXI 1407 Getting Started with Your IMAQ System NI IMAQ release notes IMAQ PCI PXI 1407 User Manual NI IMAQ for Windows 2000 NT 9x and online docu...

Страница 16: ...for enhanced triggering timing or input output For more specific information about these products refer to your National Instruments catalogue or Web site or call the office nearest you How to Set up...

Страница 17: ...ocumentation Read Chapter 1 Introduction to NI IMAQ in the NI IMAQ User Manual Read the sections in chapters 2 and 3 in the NI IMAQ User Manual that apply to the function groups you will use in your a...

Страница 18: ...the NI IMAQ driver software before installing your PCI PXI 1407 For information on how to install NI IMAQ please see the Getting Started with Your IMAQ System document and your NI IMAQ release notes P...

Страница 19: ...o the back panel rail 8 Check the installation 9 Replace the computer cover Your PCI 1407 is now installed PXI 1407 You can install a PXI 1407 in any available 5 V peripheral slot in your PXI or Compa...

Страница 20: ...g video signals into digital form The board has both gain and offset circuitry to optimize the input signal range of the ADC It also features a PCI interface for high speed data transfer The scatter g...

Страница 21: ...DC and LUT An 8 bit flash ADC digitizes the image which is passed to a 256 by 8 bit lookup table LUT RAM You can configure the input LUT to implement simple imaging operations such as contrast enhance...

Страница 22: ...Control section later in this chapter Acquisition and Region of Interest Control The acquisition and region of interest control circuitry monitors the incoming video signal and routes the active pixel...

Страница 23: ...of the PCI specification Trigger Control This circuit controls the direction and functionality of the external trigger line The trigger can start an image acquisition when used as an input signal As a...

Страница 24: ...el region is defined by a pixel start relative to HSYNC and a pixel count Horizontal count The horizontal count is the total number of pixels between two HSYNC signals The horizontal count determines...

Страница 25: ...deo Parameters You can program all of these video parameters on the PCI PXI 1407 Programmable pixel and line count The PCI PXI 1407 uses an advanced genlock circuit to generate an internal PCLK This c...

Страница 26: ...other odd line or every fourth odd line You can use the scaling down circuitry in conjunction with the region of interest circuitry Interlaced video The PCI PXI 1407 supports both interlaced and nonin...

Страница 27: ...or the PCI PXI 1407 BNC Connectors The BNC external connectors supply an immediate connection to the PCI PXI 1407 VIDEO CSYNC and TRIG inputs Use BNC cables to connect a camera to these inputs You can...

Страница 28: ...programmable to be an input or an output When the PCI PXI 1407 is in CSYNC external mode use the connector to input a CSYNC signal from the camera In standard acquisition mode the internally generated...

Страница 29: ...rmats Supported RS 170 60 Hz Interlaced mode 30 frames s CCIR 50 Hz Interlaced mode 25 frames s Video Input Quantity 1 monochrome Input impedance 75 VIDEO RSE BNC Frequency response 20 MHz 3 dB typ Ga...

Страница 30: ...equency 11 66 to 15 78 MHz Aspect correction for standard video sources 5 to 7 Pixel jitter 5 ns peak PCI Interface PCI initiator master capability Supported PCI target slave capability Supported Data...

Страница 31: ...Voltage 5 V 1 34 A 12 V 100 mA 12 V 50 mA Physical Dimensions PCI 1407 10 7 by 17 5 cm 4 2 by 6 9 in PXI 1407 16 by 10 cm 6 3 by 3 9 in Weight PCI 1407 0 127 kg 0 28 lb PXI 1407 0 145 kg 0 32 lb Envir...

Страница 32: ...ak 30 shocks per face Operational random vibration PXI Only 5 to 500 Hz 0 31 grms 3 axes Nonoperational random vibration PXI Only 5 to 500 Hz 2 5 grms 3 axes Note Random vibration profiles were develo...

Страница 33: ...ions FAQs and their corresponding answers or solutions including special sections devoted to our newest products The database is updated daily in response to new customer experiences and feedback Trou...

Страница 34: ...to provide information on local services You can access these Web sites from www ni com worldwide If you have trouble connecting to our Web site please contact your local National Instruments office...

Страница 35: ...10 12 n nano 10 9 micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 Numbers Symbols Percent Positive of or plus Negative of or minus Per Plus or minus Ohm A A Amperes A D Analog to digital AC...

Страница 36: ...s completed AQ_IN_PROGRESS Signals that the acquisition of video data is in progress area A rectangular portion of an acquisition window or frame that is controlled and defined by software array Order...

Страница 37: ...fers to the core specification defined by the PCI Industrial Computer Manufacturer s Group PICMG compiler A software utility that converts a source program in a high level programming language such as...

Страница 38: ...indows containing executable code and data that can be called or used by Windows applications or other DLLs functions and data in a DLL are loaded and linked at run time when they are referenced by a...

Страница 39: ...nal between the start of the horizontal blank and the start of the horizontal synchronization signal ft Feet function A set of software instructions executed by a single line of code that may have inp...

Страница 40: ...C Integrated circuit IEEE Institute of Electrical and Electronics Engineers in Inches INL Integral nonlinearity A measure in LSB of the worst case deviation from the ideal A D or D A transfer characte...

Страница 41: ...sfer that means 1 000 or 103 bytes s Kword 1 024 words of memory L library A file containing compiled object modules each comprised of one of more functions that can be linked to other object modules...

Страница 42: ...nging addresses on the local processor MSB Most significant bit MTBF Mean time between failure mux Multiplexer A switching device with multiple inputs that selectively connects one of its inputs to it...

Страница 43: ...o The ratio between the physical horizontal size and the vertical size of the region covered by the pixel an acquired pixel should optimally be square thus the optimal value is 1 0 but typically it fa...

Страница 44: ...ended All measurements are made with respect to a common reference measurement system or a ground Also called a grounded measurement system RTSI bus Real Time System Integration Bus The National Instr...

Страница 45: ...acquisition on a rising or falling edge TTL Transistor transistor logic V V Volts VI Virtual Instrument 1 A combination of hardware and or software elements typically used with a PC that has the funct...

Страница 46: ...on See CSYNC configuration See also installation setting up IMAQ system 2 2 to 2 3 CSYNC acquisition window control 3 5 CSYNC mux 3 3 external acquisition mode 3 7 CSYNC signal table 4 2 D delayed vid...

Страница 47: ...ne count definition 3 5 programmable pixel and line count 3 6 line region active 3 5 lookup table 8 bit ADC and LUT 3 2 M motion control and DAQ integrating with 1 6 N National Instruments web support...

Страница 48: ...rmats supported A 1 internal pixel clock A 2 PCI interface A 2 to A 3 physical A 3 power requirements A 3 video input A 1 standard acquisition mode 3 7 start conditions video acquisition 3 4 to 3 5 sy...

Отзывы: