NI DCM-23XX Getting Started Guide 

|

  © National Instruments 

|

  5

What to Do

Complete the following steps to ground the DCM.
1.

Remove the screw from the chassis ground lug on the DCM.

2.

Insert wire or braided grounding strap into the side of the chassis ground lug

3.

Tighten the grounding screw to 1.4 N · m (12 lb · in.) of torque.

4.

Attach the other end of the wire to the grounding electrode system of your facility using a 
method that is appropriate for your application.

For more information about ground connections, visit 

ni.com/info

 and enter the Info Code 

emcground

.

Connecting the DCM Starter Harness

The DCM Starter Harness contains all connections required to begin using the DCM with 
one solenoid injector and one piezo injector. The DCM Starter Harness should connect with 
the devices as shown in Figure 1.

What to Use

DCM Starter Harness

Hex Driver, 4 mm

PDU-2300

Emergency Stop (E-Stop)

What to Do

Complete the following steps to connect the DCM Starter Harness.
1.

Ensure that the PDU is disconnected from all power sources.

2.

Connect the harness to DCM Connector 1, being sure to orient the connector appropriately.

3.

Tighten the DCM connector terminal fastener to 5 N · m (44 lb · in.) of torque using a 4 mm 
Hex Driver.

4.

Ensure your PDU is correctly configured for 12 V or 24 V, whichever is used. Refer to the 

Configuring the PDU-2300

 section for more information.

5.

Connect the harness to the PDU (blue connector).

6.

Connect the harness to the emergency stop.

Содержание NI DCM-23 Series

Страница 1: ...rds Caution Do not mix hazardous voltage circuits and human accessible circuits in the same cable unless the cables are properly insulated for min 250V Caution Ensure that devices and circuits connect...

Страница 2: ...arness and DSI software For more detailed information on DCM hardware or software refer to the Related Documentation section of this guide Preparing the Environment Ensure that the environment in whic...

Страница 3: ...pplication software and device drivers on the host computer in this order NI CompactRIO Device Drivers 16 0 or later Software Calibration Management SCM Toolkit 2016 or later evaluation license Note T...

Страница 4: ...ater NI Powertrain Controls DCM Custom Device for NI VeriStand For minimum software support information visit ni com info and enter the Info Code swsupport Hardware Installation Mounting the DCM The D...

Страница 5: ...ins all connections required to begin using the DCM with one solenoid injector and one piezo injector The DCM Starter Harness should connect with the devices as shown in Figure 1 What to Use DCM Start...

Страница 6: ...ystems The PDU ships configured for 12 V systems by default Complete the following steps to configure the PDU for 24 V systems See Figure 2 below for illustration of fuse placement for 12 V and 24 V s...

Страница 7: ...nch top applications which require less than 15 A of current The heavy duty leads 8 AWG included in the DCM Starter Harness kit are recommended for all other applications What to Use Starter harness l...

Страница 8: ...T 5 or better shielded twisted pair Ethernet cable Caution To prevent data loss and to maintain the integrity of your Ethernet installation do not use a cable longer than 100 m 328 ft Note The DCM att...

Страница 9: ...ur system in the Hostname field 3 Click the Security Configuration icon 4 Click Login 5 In the Login dialog box enter the username admin and leave the password field blank 6 Click OK 7 Click Change Pa...

Страница 10: ...re Wizard Tip You must log in if you set a system password c Select the recommended software set for your LabVIEW and NI RIO Device Drivers versions d Click Next e Verify that the summary of software...

Страница 11: ...on ni com the software on your DCM may need to be updated Refer to the NI DCM 23XX DSI User s Guide for more information Troubleshooting the DCM Safe Mode and IP Reset The following figure shows the...

Страница 12: ...rmation about installing software on the chassis Amber 3 Flashes The chassis is in safe mode Refer to the Measurement Automation Explorer Help for information about safe mode Amber 4 Flashes The softw...

Страница 13: ...lp Powertrain Controls Device Drivers User s Manual in LabVIEW to view the Device Drivers User s Manual Browse the DCM section in the Contents tab for information about the DCM API VIs on the FPGA Rea...

Страница 14: ...the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for...

Страница 15: ......

Страница 16: ...m patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com leg...

Отзывы: