background image

Appendix B

Pinouts

NI PXIe-1075 User Manual

B-10

ni.com

Table B-11.  

P1 Connector Pinout for the Hybrid Slot

Pin

Z

A

B

C

D

E

F

25

GND

5V

REQ64#

ENUM#

3.3V

5V

GND

24

GND

AD[1]

5V

V(I/O)

AD[0]

ACK64#

GND

23

GND

3.3V

AD[4]

AD[3]

5V

AD[2]

GND

22

GND

AD[7]

GND

3.3V

AD[6]

AD[5]

GND

21

GND

3.3V

AD[9]

AD[8]

M66EN

C/BE[0]#

GND

20

GND

AD[12]

GND

V(I/O)

AD[11]

AD[10]

GND

19

GND

3.3V

AD[15]

AD[14]

GND

AD[13]

GND

18

GND

SERR#

GND

3.3V

PAR

C/BE[1]#

GND

17

GND

3.3V

IPMB_SCL

IPMB_SDA

GND

PERR#

GND

16

GND

DEVSEL#

GND

V(I/O)

STOP#

LOCK#

GND

15

GND

3.3V

FRAME#

IRDY#

BD_SEL#

TRDY#

GND

12–14

Key Area

11

GND

AD[18]

AD[17]

AD[16]

GND

C/BE[2]#

GND

10

GND

AD[21]

GND

3.3V

AD[20]

AD[19]

GND

9

GND

C/BE[3]#

IDSEL

AD[23]

GND

AD[22]

GND

8

GND

AD[26]

GND

V(I/O)

AD[25]

AD[24]

GND

7

GND

AD[30]

AD[29]

AD[28]

GND

AD[27]

GND

6

GND

REQ#

GND

3.3V

CLK

AD[31]

GND

5

GND

BRSVP1A5

BRSVP1B5

RST#

GND

GNT#

GND

4

GND

IPMB_PWR

HEALTHY#

V(I/O)

INTP

INTS

GND

3

GND

INTA#

INTB#

INTC#

5V

INTD#

GND

2

GND

TCK

5V

TMS

TDO

TDI

GND

1

GND

5V

–12V

TRST#

+12V

5V

GND

Содержание Network Adapter NI PXIe-1075

Страница 1: ...PXI Express NI PXIe 1075 User Manual NI PXIe 1075 User Manual July 2008 372537A 01 ...

Страница 2: ...00 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351 210 311 210 Russia 7 495 783 6851 Singapore 1800 226 5886 Slovenia 386 3 425 42 00 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 2005151 Taiwan 886 02 2377 2222 Thailan...

Страница 3: ...ding photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software is protected by copyright and other intellectual property laws Where NI software may be used to reproduce soft...

Страница 4: ...h CompactPCI 1 6 System Controller Slot 1 7 Hybrid Peripheral Slots 1 7 PXI Express Peripheral Slots 1 8 System Timing Slot 1 8 PXI Local Bus 1 9 PXI Trigger Bus 1 9 System Reference Clock 1 10 PXIe_SYNC_CTRL 1 13 Chapter 2 Installation and Configuration Safety Information 2 1 Chassis Cooling Considerations 2 2 Providing Adequate Clearance 2 2 Chassis Ambient Temperature Definition 2 4 Setting Fan...

Страница 5: ...rigger Bus Routing 2 16 Using System Configuration and Initialization Files 2 16 Chapter 3 Maintenance Service Interval 3 1 Preparation 3 1 Cleaning 3 1 Interior Cleaning 3 2 Exterior Cleaning 3 2 Cleaning the Fan Filters 3 2 Resetting the AC Mains Circuit Breaker 3 3 Replacing the Modular Power Supply Shuttle 3 3 Removal 3 4 Installation 3 4 Configuration 3 4 Connecting Safety Ground 3 4 Connecti...

Страница 6: ...ake to avoid injury data loss or a system crash When this symbol is marked on the product refer to the Read Me First Safety and Radio Frequency Interference document shipped with the product for precautions to take bold Bold text denotes items that you must select or click in the software such as menu items and dialog box options Bold text also denotes parameter names italic Italic text denotes va...

Страница 7: ...Specifications for Microcomputers Using IEC 603 2 Connectors IEEE 1101 10 IEEE Standard for Additional Mechanical Specifications for Microcomputers Using IEEE 1101 1 Equipment Practice PICMG EXP 0 R1 0 CompactPCI Express Specification PCI Industrial Computers Manufacturers Group PCI Express Base Specification Revision 1 1 PCI Special Interest Group PXI 5 PXI Express Hardware Specification Revision...

Страница 8: ...are and switches are undamaged Inspect the inner chassis for any possible damage debris or detached components If damage appears to have been caused during shipment file a claim with the carrier Retain the packing material for possible inspection and or reshipment What You Need to Get Started The NI PXIe 1075 chassis kit contains the following items NI PXIe 1075 chassis Filler panels AC power cabl...

Страница 9: ...as been optimized for maximum usability in a wide range of applications The chassis modular design ensures a high level of maintainability resulting in a very low mean time to repair MTTR The NI PXIe 1075 chassis fully complies with the PXI 5 PXI Express Hardware Specification offering advanced timing and synchronization features Table 1 1 AC Power Cables Power Cable Reference Standards Standard 1...

Страница 10: ...ts for supporting existing PXI instruments Quiet operation for 0 to 30 C at 43 6 dBA Variable speed fan controller optimizes cooling and acoustic emissions Remote power inhibit control Complies with PXI and CompactPCI Specifications High Reliability 0 to 55 C extended temperature range Power supply temperature and fan monitoring HALT tested for increased reliability Field replaceable power supply ...

Страница 11: ...w of the NI PXIe 1075 Figure 1 1 Front View of the NI PXIe 1075 Chassis 1 Chassis Carry Handle 2 Backplane Connectors 3 PXI Filler Panels 4 Chassis Model Name 5 Removable Feet 6 PXI Express Hybrid Peripheral Slots 8x 7 PXI Express Peripheral Slots 8x 8 PXI Express System Timing Slot 9 PXI Express System Controller Slot 10 Power Inhibit Switch 11 Power Inhibit Switch LED 12 System Controller Expans...

Страница 12: ...e front of the chassis The second option is a rear rack mount kit The rear rack mount kit differs from the front kit to allow for easier installation into the rack For more information refer to Figure A 3 NI Chassis Rack Mount Kit Components 1 Universal AC Input 2 Push Reset Circuit Breaker 3 Chassis Ground Screw 4 Air Filter Retainer Screws 5 Power Supply Shuttle ID Label 6 10 MHz REF OUT BNC 7 1...

Страница 13: ... chassis PXI Express compatible products CompactPCI Express compatible 4 Link system controller products CompactPCI Express compatible Type 2 peripheral products PXI peripheral products Standard CompactPCI peripheral products Refer to Figure 1 3 for an overview of the NI PXIe 1075 architecture Figure 1 3 NI PXIe 1075 Backplane Architecture PLX PEX8533 PCIe Switch 0 8 10 9 2 1 8 10 9 2 0 8 10 9 1 2...

Страница 14: ...in the Default position for the system controller to have control of the power supply Refer to the Inhibit Mode Switch section of Chapter 2 Installation and Configuration for details about the Inhibit Mode switch Hybrid Peripheral Slots The chassis provides eight hybrid peripheral slots as defined by the PXI 5 PXI Express Hardware Specification slots 2 5 and slots 15 18 A hybrid peripheral slot ca...

Страница 15: ...eral with x4 or x1 PCI Express link to the system slot through a PCIe switch The system timing slot has 3 dedicated differential pairs PXIe_DSTAR connected from the TP1 and TP2 connectors to the XP3 connector for each PXI Express peripheral or hybrid peripheral slot as well as routed back to the XP3 connector of the system timing slot as shown in Figure 1 4 The PXIe_DSTAR pairs can be used for hig...

Страница 16: ...ight PXI trigger lines You can use these trigger lines in a variety of ways For example you can use triggers to synchronize the operation of several different PXI peripheral modules In other applications one module located in the system timing slot can control carefully timed sequences of operations performed on other modules in the system Modules can pass triggers to one another allowing precisel...

Страница 17: ...lthough any trigger line may be routed in either direction it cannot be routed in more than one direction at a time Figure 1 5 PXI Trigger Bus Connectivity Diagram System Reference Clock The PXIe 1075 chassis supplies PXI_CLK10 PXIe_CLK100 and PXIe_SYNC100 to every peripheral slot with an independent driver for each signal An independent buffer having a source impedance matched to the backplane an...

Страница 18: ...buffer drives PXIe_SYNC100 to each peripheral slot The differential pair must be terminated on the peripheral with LVPECL termination for the buffer to drive PXIe_SYNC100 so that when there is no peripheral or a peripheral that does not connect to PXIe_SYNC100 there is no SYNC100 signal being driven on the pair to that slot Refer to Figure 1 6 for a termination example In summary PXI_CLK10 is driv...

Страница 19: ...this external clock and distributes these signals to the slots Refer to Appendix A Specifications for the specification information for an external clock provided on the 10 MHz REF IN connector on the rear panel of the chassis If the 10 MHz clock is present on both the PXI_CLK10_IN pin of the System Timing Slot and the 10 MHz REF IN connector on the rear of the chassis the signal on the System Tim...

Страница 20: ...etting n 3 gives a PXIe_SYNC100 with a 300ns period while still maintaining its phase relationship to PXI_CLK10 The value for n may be set to any positive integer from 1 to 255 The system timing slot has a control pin for PXIe_SYNC100 called PXIe_SYNC_CTRL for use when n 1 Refer to Table B 6 XP3 Connector Pinout for the System Timing Slot for system timing slot pinout Refer to Appendix A Specifica...

Страница 21: ...nection from the premise wire safety ground to the chassis ground The earth safety ground must be connected during use of this equipment to minimize shock hazards Refer to the Connecting Safety Ground section for instructions on connecting safety ground Live Circuits Operating personnel and service personnel must not remove protective covers when operating or servicing the chassis Adjustments and ...

Страница 22: ...ench or in an instrument rack Regardless of the configuration you must provide the cooling clearances as outlined in the following sections Providing Adequate Clearance The primary cooling exhaust vent for the NI PXIe 1075 is on the top of the chassis The primary intake vent is on the rear of the chassis where the air is filtered as it enters the power supply shuttle The secondary intake and exhau...

Страница 23: ...tallation and Configuration National Instruments Corporation 2 3 NI PXIe 1075 User Manual Figure 2 1 NI PXIe 1075 Cooling Clearances 1 75 44 45 1 75 44 45 3 00 76 20 Dimensions are in inches millimeters NI PXIe 1075 ...

Страница 24: ... in Auto Fan Speed mode Because of this the chassis ambient temperature is defined as the temperature that exists just outside of the fan intake vents on the rear of the chassis Note that this temperature may be higher than ambient room temperature depending on the surrounding equipment and or blockages present It is the user s 1 Primary Air Exhaust Vent 2 Air Filter 3 Primary Air Intake Vent 3 Se...

Страница 25: ...ng performance install filler panels provided with the chassis in unused or empty slots Secure with the captive mounting screws provided Installing Slot Blockers The cooling performance of the chassis can be improved by installing optional slot blockers Refer to ni com for more details Rack Mounting Rack mount applications require the optional rack mount kits available from National Instruments Re...

Страница 26: ...e AC power cable supplied Refer to Figure 1 2 Rear View of the NI PXIe 1075 Chassis to locate the AC inlet The Inhibit Mode switch allows you to power on the chassis or place it in standby mode Set the Inhibit Mode switch on the back of the chassis to the Manual position Observe that all fans become operational and the power switch LED is a steady green Switching the Inhibit Mode switch to the Def...

Страница 27: ... 4 When you begin to feel resistance pull up on the injector ejector handle to seat the system controller fully into the chassis frame Secure the system controller front panel to the chassis using the system controller front panel mounting screws 5 Connect the keyboard mouse and monitor to the appropriate connectors Connect devices to ports as required by your system configuration 6 Power on the c...

Страница 28: ... the system controller slot of a NI PXIe 1075 chassis You can place CompactPCI CompactPCI Express PXI or PXI Express modules in other slots depending on the slot type Figure 2 4 NI PXI Express System Controller Installed in a NI PXIe 1075 Chassis 1 NI PXIe 1075 Chassis 2 NI PXIe System Controller 3 Injector Ejector Rail 1 2 3 NI PXIe 1075 ...

Страница 29: ...all a module complete the following steps 1 Inspect the slot for any physical damage or bent pins before installing the peripheral module 2 Connect the AC power source to the PXI Express chassis before installing the module The AC power cord grounds the chassis and protects it from electrical damage while you install the module 3 Ensure that the chassis is powered off 4 Install a module into a cha...

Страница 30: ...green not flashing the chassis is powered on and operating normally If the inhibit switch LED is flashing green the air intake temperature has exceeded the chassis operating range If the inhibit switch LED is flashing red the power supply outputs are not within voltage regulation requirements If the inhibit switch LED is steady red the system fans or power supply fan has failed The remaining fans ...

Страница 31: ...iting through a female 9 pin D SUB DB 9 connector located on the rear panel as shown in Figure 1 2 Rear View of the NI PXIe 1075 Chassis Table 2 1 shows the pinout of the 9 pin D SUB DB 9 connector Caution When connecting digital voltmeter probes to the rear 9 pin D SUB DB 9 connector be careful not to short the probe leads together Doing so could damage the power supply Table 2 1 Remote Inhibit a...

Страница 32: ...ications Inhibit Mode Switch On the rear panel of the chassis there is an Inhibit Mode switch Refer to Figure 1 2 Rear View of the NI PXIe 1075 Chassis for the location The Inhibit Mode switch is recessed to prevent it from accidentally being switched The Inhibit Mode switch should be in the Default position when you want the system controller to control the power supply inhibit If the user needs ...

Страница 33: ...o another chassis Refer to the System Reference Clock section of Chapter 1 Getting Started for details about these signals PXI Express System Configuration with MAX The PXI Platform Services software included with your chassis automatically identifies your PXI Express system components to generate a pxiesys ini file You can configure your entire PXI system and identify PXI 1 chassis through Measur...

Страница 34: ... Configuration 1 Launch MAX 2 In the Configuration tree click the Devices and Interfaces branch to expand it 3 If the PXI system controller has not yet been configured it is labeled PXI System Unidentified Right click this entry to display the pop up menu then select the appropriate system controller model from the Identify As submenu ...

Страница 35: ...le provided by the chassis manufacturer The information in this file is combined with information about the system controller to create a single PXI 1 system initialization file called pxisys ini PXI System Initialization The NI system controller uses MAX to generate the pxisys ini file from the chassis ini file Device drivers and other utility software read the pxiesys ini and pxisys ini file to ...

Страница 36: ...e trigger lines for you so you won t have to route trigger lines manually Complete the following steps to configure trigger routings in MAX 1 In the Configuration tree select the chassis in which you want to route trigger lines 2 In the right hand pane select the Trigger Routing tab near the bottom 3 For each trigger line select Route Right Route Outward From Middle or Route Left to route triggers...

Страница 37: ...sis model that contains the system controller or provides a utility that can read an arbitrary chassis ini file and generate the corresponding pxisys ini file System controllers from NI provide the pxisys ini file for the NI PXIe 1075 chassis so you should not need to use the chassis ini file Refer to the documentation provided with the system controller or to ni com support for more information o...

Страница 38: ... cooling performance Preparation The information in this section is designed for use by qualified service personnel Read the Read Me First Safety and Radio Frequency Interference document included with your kit before attempting any procedures in this chapter Caution Many components within the chassis are susceptible to static discharge damage Service the chassis only in a static free environment ...

Страница 39: ...s while cleaning the chassis Do not use harsh chemical cleaning agents they may damage the chassis Avoid chemicals that contain benzene toluene xylene acetone or similar solvents Cleaning the Fan Filters A dirty fan filter can dramatically affect the cooling performance of an NI PXIe 1075 chassis Clean the filter whenever it becomes visibly dirty You can easily remove the chassis air filters from ...

Страница 40: ...ch LED is not a steady green contact National Instruments 5 Verify that the NI PXIe 1075 chassis can meet the power requirements of your CompactPCI or PXI Express modules Overloading the chassis can cause the breaker to trip Refer to Appendix A Specifications 6 The over current condition that caused the circuit breaker to trip may be due to a faulty CompactPCI or PXI Express module Refer to the do...

Страница 41: ... power supply shuttle to remove it from the back of the chassis Installation Ensure that there is no visible damage to the new power supply shuttle Verify that the housing and connector on the new power supply shuttle have no foreign material inside Remove the protective cap on the PXI_CLK10 connector Install the new power supply shuttle into the opening on the rear of the chassis Replace and tigh...

Страница 42: ...are subject to change without notice Electrical AC Input Input voltage rating 100 to 120 VAC 220 to 240 VAC Operating voltage range1 90 to 120 VAC 200 to 264 VAC Input current rating 12 A 6 A Input frequency 50 60 Hz Over current protection 15 A circuit breaker Line regulation 3 3 V 0 2 5 V 0 1 12 V 0 1 Efficiency 70 typical 1 The operating range is guaranteed by design ...

Страница 43: ...ackplane You also can use the rear panel D SUB 9 pin connector and power mode switch to control the internal chassis power supply For more information refer to the Inhibit Mode Switch section of Chapter 2 Installation and Configuration DC Output DC current capacity IMP Notes Maximum total power is 791 W The maximum power dissipated in the system slot should not exceed 140 W Voltage Maximum Current...

Страница 44: ...above nominal output voltage Power supply shuttle MTTR Replacement in under 5 minutes Slot 5 V V I O 3 3 V 12 V 12 V 5 VAUX System Controller Slot 9 A 0 A 9 A 11 A 0 A 1 A System Timing Slot 0 A 0 A 3 A 2 A 0 A 1 A Hybrid Peripheral Slot with PXI 1 Peripheral 6 A 5 A 6 A 1 A 1 A 0 A Hybrid Peripheral Slot with PXI 5 Peripheral 0 A 0 A 3 A 3 A 0 A 1 A PXI 1 Peripheral Slot 6 A 11 A 6 A 1 A 1 A 0 A ...

Страница 45: ... supply cooling system Forced air circulation through two integrated fans Power supply cooling intake Right side of chassis Power supply cooling exhaust Left side of chassis Clearance for intake exhaust vents 1 75 in 44 45 cm for top and side vents 3 00 in 76 20 for back vents Maximum fan cleaning interval 6 months Fan filter material 30 ppi 3 32 in 0 24 cm polyurethane foam Refer to the Cleaning ...

Страница 46: ...e Environment Ambient temperature range 40 to 71 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 limits Relative humidity range 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Operational shock 30 g peak half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 Meets MIL PRF 28800F Class 2 limits Random Vibration 5 to...

Страница 47: ... This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the product label or visit ni com certification search by model number or product line and click the appropriate link in the Certification column...

Страница 48: ...sible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers For additional environmental information refer to the NI and the Environment Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not ...

Страница 49: ... 0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076 4 101 and are UL 94 V 0 rated System Synchronization Clocks PXI_CLK10 PXIe_CLK100 PXIe_SYNC100 10 MHz System Reference Clock PXI_CLK10 Maximum slot to slot skew 500 ps Accuracy 25 ppm max guaranteed over the operating temperature range Note The 10 MHz system reference clock does not require calibration Maximum jitter 5 ps RMS phas...

Страница 50: ...Hz range Duty factor for PXIe_CLK100 45 55 Absolute single ended voltage swing When each line in the differential pair has 50 W termination to 1 30 V or Thévenin equivalent 400 1000 mV Note For other specifications refer to the PXI 5 PXI Express Hardware Specification External 10 MHz Reference Out BNC on rear panel of chassis Accuracy 25 ppm max guaranteed over the operating temperature range Maxi...

Страница 51: ... ps RMS phase jitter 10 Hz 1 MHz range PXIe_SYNC_CTRL VIH 2 0 5 5 V VIL 0 0 8 V PXI Star Trigger Maximum slot to slot skew 250 ps Backplane characteristic impedance 65 Ω 10 Notes For PXI slot to PXI Star mapping refer to the System Timing Slot section of Chapter 1 Getting Started For other specifications refer to the PXI 1 Hardware Specification PXI Differential Star Triggers PXIe DSTARA PXIe DSTA...

Страница 52: ... top height is increased approximately 2 08 in 52 8 mm in front and 0 583 in 14 8 mm in rear Weight 14 06 kg 31 0 lb Chassis materials Sheet Aluminum 5052 H32 3003 H14 and 6061 T6 Extruded Aluminum 6060 T6 and Cold Rolled Steel PC ABS Santoprene Nylon Finish Conductive Clear Iridite on Aluminum Electroplated Nickel on Cold Rolled Steel Polyurethane Enamel Figures A 1 and A 2 show the NI PXIe 1075 ...

Страница 53: ...I PXIe 1075 Chassis Dimensions Front and Side Dimensions are in inches millimeters 0 57 14 5 39 9 9 17 54 445 6 6 97 177 1 1 14 0 30 7 25 3 54 90 0 1 84 46 8 17 11 434 6 3 19 81 1 2 12 53 8 1 58 40 1 29 1 1 37 34 8 10 21 259 1 1 82 46 3 1 82 46 3 Front of PXI Card NI PXIe 1075 ...

Страница 54: ...pecifications National Instruments Corporation A 13 NI PXIe 1075 User Manual Figure A 2 NI PXIe 1075 Chassis Dimensions Bottom 1 017 25 83 2 524 64 11 15 504 393 8 12 700 322 58 Dimensions are in inches millimeters ...

Страница 55: ...nt Kit Components Notes The chassis shown in Figure A 3 is representative of the NI PXI 1044 1045 and NI PXIe 1075 product line For more information on rack mounting the NI PXIe 1075 chassis refer to the printed installation guide included with your rack mount kit 1 Front Rack Mount Kit 2 NI Chassis 3 Optional Rear Rack Mount Kit 3 NI PXIe 1075 2 1 ...

Страница 56: ...ws the XP1 connector pinout for the System Controller slot Table B 5 shows the XP4 Connector Pinout for the System Timing slot Table B 6 shows the XP3 Connector Pinout for the System Timing slot Table B 7 shows the TP2 Connector Pinout for the System Timing slot Table B 8 shows the TP1 Connector Pinout for the System Timing slot Table B 9 shows the XP4 Connector Pinout for the Hybrid peripheral sl...

Страница 57: ...or Table B 1 XP4 Connector Pinout for the System Controller Slot Pin Z A B C D E F 1 GND GA4 GA3 GA2 GA1 GA0 GND 2 GND 5Vaux GND SYSEN WAKE ALERT GND 3 GND RSV RSV RSV RSV RSV GND 4 GND RSV RSV RSV RSV RSV GND 5 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 GND PXI_TRIG6 GND 6 GND PXI_TRIG2 GND RSV PXI_STAR PXI_CLK10 GND 7 GND PXI_TRIG1 PXI_TRIG0 RSV GND PXI_TRIG7 GND 8 GND RSV GND RSV RSV PXI_LBR6 GND 4 3 1 ...

Страница 58: ...2PETn0 GND 8 2PETp1 2PETn1 GND 2PERp1 2PERn1 GND 2PERp0 2PERn0 GND 9 2PETp2 2PETn2 GND 2PERp2 2PERn2 GND 2PETp3 2PETn3 GND 10 3PETp0 3PETn0 GND 3PERp0 3PERn0 GND 2PERp3 2PERn3 GND Table B 3 XP2 Connector Pinout for the System Controller Slot Pin A B ab C D cd E F ef 1 3PETp1 3PETn1 GND 3PERp1 3PERn1 GND 3PETp2 3PETn2 GND 2 3PETp3 3PETn3 GND 3PERp3 3PERn3 GND 3PERp2 3PERn2 GND 3 4PETp0 4PETn0 GND 4...

Страница 59: ...em Timing Slot Pinouts Figure B 2 PXI Express System Timing Slot Layout Table B 4 XP1 Connector Pinout for the System Controller Slot Pins Signals A GND B 12V C 12V D GND E 5V F 3 3V G GND 1 XP4 Connector 2 XP3 Connector 3 TP2 Connector 4 TP1 Connector 4 3 1 2 ...

Страница 60: ...XI_LBR6 GND Table B 6 XP3 Connector Pinout for the System Timing Slot Pin A B ab C D cd E F ef 1 PXIe_CLK 100 PXIe_ CLK100 GND PXIe_ SYNC100 PXIe_ SYNC100 GND PXIe_ DSTARC PXIe_ DSTARC GND 2 PRSNT PWREN GND PXIe_ DSTARB PXIe_ DSTARB GND PXIe_ DSTARA PXIe_ DSTARA GND 3 SMBDAT SMBCLK GND RSV RSV GND RSV RSV GND 4 MPWRGD PERST GND RSV RSV GND 1RefClk 1RefClk GND 5 1PETp0 1PETn0 GND 1PERp0 1PERn0 GND ...

Страница 61: ...ARB1 PXIe_ DSTARB1 GND PXI_STAR0 PXI_STAR1 GND PXIe_ DSTARB9 PXIe_ DSTARB9 GND 5 PXIe_ DSTARA1 PXIe_ DSTARA1 GND PXI_STAR2 PXI_STAR3 GND PXIe_ DSTARC10 PXIe_ DSTARC10 GND 6 PXIe_ DSTARC2 PXIe_ DSTARC2 GND PXI_STAR4 PXI_STAR5 GND PXIe_ DSTARA10 PXIe_ DSTARA10 GND 7 PXIe_ DSTARB2 PXIe_ DSTARB2 GND PXI_STAR6 PXI_STAR7 GND PXIe_ DSTARB10 PXIe_ DSTARB10 GND 8 PXIe_ DSTARA2 PXIe_ DSTARA2 GND PXI_STAR8 P...

Страница 62: ...A4 PXIe_ DSTARA4 GND PXIe_ DSTARB7 PXIe_ DSTARB7 GND PXIe_ DSTARC13 PXIe_ DSTARC13 GND 5 PXIe_ DSTARC5 PXIe_ DSTARC5 GND PXI_STAR14 PXI_ STAR15 GND PXIe_ DSTARA13 PXIe_ DSTARA13 GND 6 PXIe_ DSTARB5 PXIe_ DSTARB5 GND PXIe_ DSTARB16 PXIe_ DSTARB16 GND PXIe_ DSTARB13 PXIe_ DSTARB13 GND 7 PXIe_ DSTARA5 PXIe_ DSTARA5 GND PXIe_ DSTARA7 PXIe_ DSTARA7 GND PXIe_ DSTARC14 PXIe_ DSTARC14 GND 8 PXIe_ DSTARC6 ...

Страница 63: ... Connector Pinout for the Hybrid Slot Pin Z A B C D E F 1 GND GA4 GA3 GA2 GA1 GA0 GND 2 GND 5Vaux GND SYSEN WAKE ALERT GND 3 GND 12V 12V GND GND GND GND 4 GND GND GND 3 3V 3 3V 3 3V GND 5 GND PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 GND PXI_TRIG6 GND 6 GND PXI_TRIG2 GND ATNLED PXI_STAR PXI_CLK10 GND 7 GND PXI_TRIG1 PXI_TRIG0 ATNSW GND PXI_TRIG7 GND 8 GND RSV GND RSV PXI_LBL6 PXI_LBR6 GND 3 1 2 ...

Страница 64: ..._ DSTARB PXIe_ DSTARB GND PXIe_ DSTARA PXIe_ DSTARA GND 3 SMBDAT SMBCLK GND RSV RSV GND RSV RSV GND 4 MPWRGD PERST GND RSV RSV GND 1RefClk 1RefClk GND 5 1PETp0 1PETn0 GND 1PERp0 1PERn0 GND 1PETp1 1PETn1 GND 6 1PETp2 1PETn2 GND 1PERp2 1PERn2 GND 1PERp1 1PERn1 GND 7 1PETp3 1PETn3 GND 1PERp3 1PERn3 GND 1PETp4 1PETn4 GND 8 1PETp5 1PETn5 GND 1PERp5 1PERn5 GND 1PERp4 1PERn4 GND 9 1PETp6 1PETn6 GND 1PERp...

Страница 65: ... GND 18 GND SERR GND 3 3V PAR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BD_SEL TRDY GND 12 14 Key Area 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8 GND AD 26 GND V I O AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ GND 3 3V CLK AD 31 GN...

Страница 66: ... Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to on demand training modules via the Services Resource Center NI offers complementary membership for a full year after purchase after which you may renew to continue your benefits For information about other techni...

Страница 67: ...ompatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front of this manual You also can visit the Worldwide Offices section of ni com niglobal to access the branch offic...

Страница 68: ... pico 10 12 n nano 10 9 μ micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Equal or greater than Equal or less than Percent A A Amperes AC Alternating current ANSI American National Standards Institute Auto Automatic fan speed control AWG American Wire Gauge ...

Страница 69: ...quiring a more robust mechanical form factor than desktop PCI It uses industry standard mechanical components and high performance connector technologies to provide an optimized system intended for rugged applications It is electrically compatible with the PCI Specification which enables low cost PCI components to be utilized in a mechanical form factor suited for rugged environments CSA Canadian ...

Страница 70: ...dule front panel used to fill empty slots in the chassis G g 1 grams 2 a measure of acceleration equal to 9 8 m s2 GPIB General Purpose Interface Bus IEEE 488 gRMS A measure of random vibration The root mean square of acceleration levels in a random vibration test profile H hr Hours Hz Hertz cycles per second I IEC International Electrotechnical Commission an organization that sets international e...

Страница 71: ...maximum steady state percentage that a DC voltage output will change as a result of a specified change in input AC voltage step change from 90 to 132 VAC or 180 to 264 VAC load regulation The maximum steady state percentage that a DC voltage output will change as a result of a step change from no load to full load output current M m Meters MHz Megahertz One million Hertz one Hertz equals one cycle...

Страница 72: ... Deviation in signal transmission times slot blocker An assembly installed into an empty slot to improve the airflow in adjacent slots standby The backplane is unpowered off but the chassis is still connected to AC power mains System controller A module configured for installation in Slot 1of a PXI chassis This device is unique in the PXI system in that it performs the system controller functions ...

Страница 73: ...ltiple modules in a measurement or control system The 10 MHz REF IN and OUT BNC connectors on the rear of the chassis can be used to synchronize multiple chassis to one reference clock The PXI backplane specification defines implementation guidelines for PXI_CLK10 System Timing slot This slot is located at slot 4 and has dedicated trigger lines to other slots T TTL Transistor transistor logic U UL...

Страница 74: ... 2 3 vents figure 2 4 chassis initialization file 2 16 chassis ventilation figure 2 4 clearances for chassis cooling 2 2 figure 2 3 CLK10 rear connectors 2 13 CompactPCI interoperability with NI PXIe 1075 backplane 1 6 configuration in MAX figure 2 14 configuration See installation configuration and operation connector pinouts See pinouts conventions used in the manual vii cooling air cooling of P...

Страница 75: ... 2 13 PXI Express system controller installed in a NI PXIe 1075 chassis figure 2 8 PXI 1 configuration in MAX 2 14 rack mounting 2 5 remote voltage monitoring and inhibiting interface 2 11 setting fan speed 2 5 site considerations 2 2 slot blocker installation 2 5 testing power up 2 6 unpacking the PXIe 1075 1 1 installing a PXI Express system controller figure 2 7 instrument drivers NI resources ...

Страница 76: ...able 1 2 power cables table 1 2 power inhibit switch LED indicator 2 10 power supply connecting to 2 6 remote voltage monitoring and inhibiting interface 2 11 replacing 3 3 configuration 3 4 connecting safety ground 3 4 connecting to power source 3 4 installation 3 4 removal 3 4 voltages at voltage monitoring connector DB 9 table 2 11 power up testing 2 6 programming examples NI resources C 1 PXI ...

Страница 77: ...environment A 5 external clock source A 10 mechanical A 11 PXI differential star triggers PXIe DSTARA PXIe DSTARB PXIe DSTARC A 10 PXI star trigger A 10 PXIe_SYNC_CTRL A 10 rack mount kit dimensions figure A 14 safety A 6 shock and vibration A 5 system reference clocks A 8 static discharge damage caution 3 1 support technical C 1 system controller slot description 1 7 pinouts XP1 connector table B...

Страница 78: ...Index National Instruments Corporation I 5 NI PXIe 1075 User Manual V voltage monitoring connector See DB 9 connector voltages at voltage monitoring connector DB 9 table 2 12 W Web resources C 1 ...

Отзывы: