B-24
|
ni.com
Appendix B
Specifications
Cleaning
If you need to clean the module, use a soft, nonmetallic brush. Make sure that the module is
completely dry and free from contaminants before returning it to service.
NI PXI-8368 (157298x-02L)
Note
These specifications are typical at 25 °C, unless otherwise stated, and are
subject to change without notice.
Physical
Dimensions
10.0 cm × 16.0 cm (3.9 in. × 6.3 in.)
Maximum cable length
200 m
Slot requirements
One PXI controller slot
Compatibility
Fully compatible with the
PXI Hardware
Specification
, Revision 1.0
Weight
0.25 kg (0.55 lb) typical
Power Requirements
Environment
Maximum altitude
2,000 m
Pollution Degree
2
Indoor use only.
Power Rail
Typical Current
Maximum Current
+3.3 V
775 mA
1.25 A
+5 V
5 mA
20 mA
+12 V
200 mA
350 mA
-12 V
0 A
0 A