Power Requirements
Environment
Maximum altitude
2,000 m
Pollution Degree
2
Indoor use only.
Operating Environment
Ambient temperature range
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
LED
Color
Meaning
PWR/LINK
Off
Power is off
Blinking Red
Power is out of spec
Solid Amber
Power is within spec; no link to chassis
Solid Green
Power is within spec; link established
Power Rail
Typical Current
Maximum Current
+3.3 V
525 mA
800 mA
+5 V
8 mA
10 mA
+12 V
10 mA
12 mA
-12 V
0 A
0 A
VIO
0 A
1 mA