cRIO-9002/9004 Specifications
The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.
Caution
Do not operate the cRIO-9002/9004 in a manner not specified in this
document. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to NI for repair.
Network
Network interface
10Base-T and 100Base-TX Ethernet
Compatibility
IEEE 802.3
Communication rates
10 Mbps, 100 Mbps, auto-negotiated
Maximum cabling distance
100 m/segment
RS-232 Serial Port
Maximum baud rate
115,200 bps
Data bits
5, 6, 7, 8
Stop bits
1, 2
Parity
Odd, Even, Mark, Space
Flow control
RTS/CTS, XON/XOFF, DTR/DSR
Memory
cRIO-9002
Nonvolatile
64 MB
DRAM
32 MB
cRIO-9004
Nonvolatile
512 MB
DRAM
64 MB
12
|