![National Instruments AT-MIO/AI E Series Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/national-instruments/at-mio-ai-e-series/at-mio-ai-e-series_user-manual_708957062.webp)
Chapter 4 Signal Connections
National Instruments Corporation
4-13
AT-MIO/AI E Series User Manual
PFI5/UPDATE*
DIO
—
Vcc +0.5
3.5 at (Vcc -0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI6/WFTRIG
DIO
—
Vcc +0.5
3.5 at (Vcc -0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI7/STARTSCAN
DIO
—
Vcc +0.5
3.5 at (Vcc -0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI8/GPCTR0_SOURCE
DIO
—
Vcc +0.5
3.5 at (Vcc -0.4)
5 at 0.4
1.5
50 k
Ω
pu
PFI9/GPCTR0_GATE
DIO
—
Vcc +0.5
3.5 at (Vcc -0.4)
5 at 0.4
1.5
50 k
Ω
pu
GPCTR0_OUT
DO
—
—
3.5 at (Vcc -0.4)
5 at 0.4
1.5
50 k
Ω
pu
FREQ_OUT
DO
—
—
3.5 at (Vcc-0.4)
5 at 0.4
1.5
50 k
Ω
pu
AI = Analog Input DIO = Digital Input/Output pu = pullup
AO = Analog Output DO = Digital Output
Note:
The tolerance on the 50 k
Ω
pullup and pulldown resistors is very large. Actual value may range between
17 k
Ω
and 100 k
Ω
.
Table 4-3.
I/O Signal Summary, AT-MIO-16XE-10 and AT-AI-16XE-10 (Continued)
Signal Name
Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mA at V)
Sink
(mA at
V)
Rise
Time
(ns)
Bias