Chapter 4 Signal Connections
National Instruments Corporation
4-55
AT-MIO/AI E Series User Manual
Mode 1 Input Timing
The following are the timing specifications for an input transfer in
Mode 1:
Figure 4-38.
Mode 1 Input Timing
Name
Description
Minimum
Maximum
T1
STB* Pulse Width
100
–
T2
STB* = 0 to IBF = 1
–
150
T3
Data before STB* = 1
20
–
T4
STB* = 1 to INTR = 1
–
150
T5
Data after STB* = 1
50
–
T6
RD* = 0 to INTR = 0
–
200
T7
RD* = 1 to IBF = 0
–
150
All timing values are in nanoseconds.
DATA
RD *
INTR
IBF
STB *
T1
T2
T4
T7
T6
T3
T5