Configuration and Installation
Chapter 2
AT-DIO-32F User Manual
2-4
© National Instruments Corporation
Base I/O Address Selection
The base I/O address for the AT-DIO-32F is determined by the switches at position U61 (see
Figure 2-1). The switches are set at the factory for the base I/O address hex 240. This factory
setting is used as the default base I/O address value by National Instruments software packages
using the AT-DIO-32F. The AT-DIO-32F uses the base I/O address space hex 240 through 25F
with the factory setting.
Note: Verify that this space is not already used by other equipment installed in your
computer. If any equipment in your computer uses this base I/O address space, change
the base I/O address of the AT-DIO-32F or of the other device. If you change the AT-
DIO-32F base I/O address, make a corresponding change to any software packages
you use with the AT-DIO-32F. Table 2-2 lists the default settings of other National
Instruments products for the PC. For more information about the I/O address of your
PC, refer to the technical reference manual for your computer.