Page 20
Natcomm
PROGRAMMING PROCEDURE
1.
TURN OFF POWER TO YOUR UNIT
2.
SWITCH ON POWER AND PRESS #
(use a Telephone connected to DS2)
3.
YOUR UNIT WILL OUTPUT 3 SHORT ‘BEEPS’
(you are in Program Mode)
If you do not hear 3 beeps, return to the start (1).
4.
ENTER ANY PROGRAMMING COMMANDS AS FOLLOWS
:
(Note - You can change one or more parameters in any order)
A.
NUMBER OF RINGS
To enter the NUMBER OF RINGS press #1xx where xx = number of
rings and can be 01-99 (for example, press #115 for 15 rings)
B.
DOOR PHONE CALL ADVICE TONES
To disable TONES press #40 To enable TONES press #41
C.
LOCK TIME SET UP
To enter the LOCK 1 OPEN TIME press #6xx
xx = time limit in seconds that LOCK 1 will remain open after pressing **.
It can be set from 01-99 (seconds)
(for example, press #630 for 30 seconds)
D.
RESET TO FACTORY DEFAULT SETTINGS
To RESET to Factory Defaults, press
13579
TO EXIT PROGRAMMING MODE - HANG UP.
ALL ENTRIES ARE SAVED IN PERMANENT MEMORY.