14
Natcomm
LOCK CONTROL
Your DS2 is provided with an internal relay which can be used to control a
Door or Gate Lock. To OPEN the Door/Gate Lock after answering a call from
your DOOR PHONE you need to press
**
on your telephone. The lock will
remain open for 10 seconds (Default setting). It can be set from 01-99 secs.
Your Door/Gate Lock can also be OPENED at any time by picking up any
telephone and dialling
**
. The Door/Gate Lock will remain UNLOCKED for 10
seconds (can be 01-99 secs).
You do not need to receive a call from the Door Phone first.
Relay Specification - Dry Relay Contacts rated at 12V/1Amp.
Do not use the supplied DS2 Controller 12V plug pack to also provide
12V power for the lock, as this may cause damage to DS2. You must use
a separate 12V source, with a maximum rating of 12V/1A.