OVERALL APPLIANCE AND CONTROL OPERATION

A normal operating sequence is as follows:

1.

The control determines that the actual water temperature inside tank is 4 degrees F., with the factory set 8 degree F.
differential, below programmed temperature set point;
The control performs selected system diagnostic checks;
If all checks are successfully passed, the combustion blower is energized for the 40 second pre-purge cycle;
During the pre-purge cycle is complete, power is applied to the ignitor element for the ignitor warm-up period (blower should
continue to run);
The ignitor warm-up period will last for 30 seconds, then gas valve will be opened, allowing gas to enter the burner chamber;
The ignitor will remain on for an additional 4 seconds, then it will be turned off;
After an additional 2 seconds, the control will verify the presence of flame. If the flame was not established, the gas valve will
be closed, power will be removed from the ignitor element, and the control will run the blower for 30 seconds. At this point,
the control will return to step 2;
If flame is present, the control will enter the heating mode where it will continue heating the tank water until the set point
temperature plus 4 degrees F. is reached. At this point, the gas valve is closed and the control enters the post-purge cycle.
The flame can be viewed through a window on the lower right of combustion blower flange;
The post-purge cycle continues to run the combustion blower for an additional 30 seconds to purge the system of all
combustion gases. After this time period, the blower is de-energized and will coast to a stop;
The control will now enter the idle state while continuing to monitor internal tank water temperature. If the temperature drops
to 4 degrees F. below the set point value, the control will automatically return to step 1.

2.
3.
4.

5.
6.
7.

8.

9.

10.

STATUS INDICATORS

Pages 15, 16, and 17

contain seven individual diagrams which illustrate the various operating states of the appliance and their relation

to the LED status indicators found on the controller. These diagrams reflect normal water heater operation.

MAINTENANCE

The control system requires no periodic maintenance under normal conditions. However, in unusually dirty or dusty conditions, period-
ic vacuuming of the cover to maintain visibility of the display and indicators is recommended. In dirty environments, construction sites,
building constructions, care must be taken to keep the appliance door in place and drywall or saw dust away from appliance.

INTERNAL WIRING

For specific wiring information, please refer to the diagrams on

pages 18 and 19

.

SHUTDOWN PROCEDURE

If the burner is operating, lower the set point value to 70 degrees F. and wait for the burner to shut off. Continue to wait for the com-
bustion blower to stop so all latent combustion gases are purged from the system. This should take a maximum of 40 to 90 seconds.
Disconnect the electrical supply. If the burner is not operating, disconnect the electrical supply.

VACATION PROCEDURE

If there is danger of freezing, change the set point to 70 degrees F. DO NOT turn off electrical power.

If there is no danger of

freezing, follow the "Shutdown Procedure".

FAILURE TO OPERATE

Should the burner fail to light, the control will perform two more ignition trials prior to entering a lockout state (“LOC”). Note that each
subsequent ignition trial will not occur immediately. After a failed ignition trial, the blower must run for approximately 10 seconds to
purge the system, then the ignitor element must complete a 30 second warm-up period. Therefore, a time period of approximately 40
to 90 seconds will expire between each ignition trial. If the burner lights during any one of these three ignition trails, normal operation
will resume.  If the burner lights, but goes off in about 4 seconds, check the polarity of the wiring. See electrical connection section on
page 4.  If the burner does not light after the third ignition trial, the control will enter a lockout state. This lockout state indicates that a
problem exists with either the appliance, the controls, or the gas supply. Under such circumstances, a qualified service technician
should be contacted immediately to properly service the appliance and correct the problem. If a technician is not available, depressing
the red button once will remove the lockout state so additional trials for ignition can be performed.

Any time “LOC” is shown, you

must look for an LED out, or flashing. The LED that is out or flashing will assist you in diagnosing lock out condition.

PAGE: 11

CAUTION

In unusually dirty or dusty conditions, care must be taken to keep appliance door in place. Failure to

do so VOIDS WARRANTY!

Содержание ANSI Z 21.10.3

Страница 1: ... 1 888 OK NATCO FAX 1 718 291 6870 sales cust svc or visit our website at www nationalcombustion com 2006 2005 2004 National Combustion Co Inc PAGE 1 LP 41 REV 1 1 06 OPERATING INSTALLATION AND SERVICE MANUAL FOR THE VOYAGER GAS FIRED WATER HEATER SUPER HIGH EFFICIENCY GAS FIRED WATER HEATING COMBINATION APPLIANCE ...

Страница 2: ...PAGE 2 ...

Страница 3: ...s opened or panel is removed Under no circum stances shall National Combustion Co Inc be held liable for any such water damage whatsoever This water heater must not be located near flammable liquids such as gasoline adhesives solvents paint thinners butane liquefied propane etc as the controls of this appliance could ignite those vapors causing an explosion TEMPERATURE AND PRESSURE RELIEF VALVE A ...

Страница 4: ...It could take as long as 5 minutes before the water heater will physically lock out during the water heater operation Remedy Low water condition in tank Turn off the electric supply make sure that the cold water supply is turned on and the water heater is completely filled with water Verify this by opening a hot water faucet allowing the water to flow until all the air is removed and clear water i...

Страница 5: ... entire gas line to the connection at the Super E is no smaller than 3 4 In the event the gas valve is exposed to a pressure greater than 1 2 PSI 14 water column the gas valve must be replaced Failure to follow all precautions below could result in fire explosion or death LP or liquefied petroleum or propane gas or Nat natural gas or city gas All gas connections must be approved by the local gas s...

Страница 6: ... elbow allowances intake and exhaust each elbow 5 of pipe should not exceed 85 The combined vent length should not be less than a combined length of 6 plus two 90 degree elbows Choose your vent termination locations carefully see pages 22 and 23 You must additionally make certain that exhaust gas does not re circulate back into the intake pipe You must place them in a open area and follow the foll...

Страница 7: ... venting as long as pipe conforms to ASTM D3965 D2661 and fittings meet ASTM D2661 D3311 Foam core pipe may be used for the entire intake system providing it conforms to ASTM F 891 and is cemented together using above materials FORLONGER VENT LENGTHS All venting must be 3 both intake and exhaust NEVER use any piping less than 3 or different size pipe on the intake and exhaust You may use 4 venting...

Страница 8: ...5 30 6 5 30 60 30 7 5 35 65 30 8 5 40 70 30 9 5 45 75 30 10 5 50 80 30 11 5 55 85 40 3 5 15 55 40 4 5 20 60 40 5 5 25 65 40 6 5 30 70 40 7 5 35 75 40 8 5 40 80 40 9 5 45 85 50 3 5 15 65 50 4 5 20 70 50 5 5 25 75 50 6 5 30 80 50 7 5 35 85 60 3 5 15 75 60 4 5 20 80 60 5 5 25 85 70 3 5 15 85 FRICTION LOSS EQUIVALENCE TABLES 2 VENTED MODELS AFTER THE FIRST 10 OF 3 3 VENTED MODELS SSV100 45R SSV130 45R...

Страница 9: ...iency appliance therefore this unit has a condensate removal system Condensate is nothing more than water vapor derived from the combustion products similar to an automobile when it is initially started This condensate does have a low PH and should be treated with a condensate filter This filter contains either lime crystals or marble crystals which will neutralize the condensate The outlet of the...

Страница 10: ... are available VERY IMPORTANT NOTE POWER MUST BE APPLIED TO THE CONTROLLER PRIOR TO ANY PROGRAMMING OPERATIONS SET POINTADJUSTMENT PROCEDURE CONTINUED To change or access the programmed temperature set point value utilize the red button on the display panel Momentarily depressing the button will briefly illustrate the existing set point value If the button is held down for more than one second the...

Страница 11: ...onditions period ic vacuuming of the cover to maintain visibility of the display and indicators is recommended In dirty environments construction sites building constructions care must be taken to keep the appliance door in place and drywall or saw dust away from appliance INTERNAL WIRING For specific wiring information please refer to the diagrams on pages 18 and 19 SHUTDOWN PROCEDURE If the burn...

Страница 12: ...PAGE 12 ...

Страница 13: ...his is only a guide to correct orifice sizing WARNING If orifices are drilled the result will be poor ignition explosion severe bodily injury or death All orifices must be obtained through the factory with all necessary labels and the serial number must be provided to the factory OR WARRANTY WILL BE VOIDED SUPER E GAS CONVERSION INSTRUCTIONS FOR CONVERSION OF THE VOYAGER TO PROPANE OR NATURAL GAS ...

Страница 14: ...iance In certain circumstances multiple LED s may be lit or flashing to better pinpoint the problem Also there is a green LED on the main control board to indicate proper polarity and grounding The following charts diagrams and information can be used during troubleshooting procedures LED CONTROLLER FUNCTION MEANING LINE MONITORS INCOMING AC LINE VOLTAGE ON WHEN LINE VOLTAGE IS PRESENT BLOWER MONI...

Страница 15: ...PAGE 15 ...

Страница 16: ...PAGE 16 ...

Страница 17: ...PAGE 17 ...

Страница 18: ...PAGE 18 ...

Страница 19: ...PAGE 19 ...

Страница 20: ...ds for venting the Super E can be found on pages 22 and 23 Use the following layout as a guideline certain site conditions such as multiple roof lines pitches may require venting modifications consult factory The air inlet must be a minimum of 1 vertically above the maximum snow level of 24 whichever is greater The air inlet must also be a minimum of 10 horizontally from the roof and terminated wi...

Страница 21: ...PAGE 21 Figure 3 A Direct Vent Terminal Clearances per ANSI Z21 10 3 2004 CSA 4 3 2004 ...

Страница 22: ...PAGE 22 ...

Страница 23: ...PAGE 23 ...

Страница 24: ...PAGE 24 ...

Страница 25: ...PAGE 25 ...

Страница 26: ...PAGE 26 ...

Страница 27: ...THE GAS VALVE BY PRESSING ON THE TABS ON THE TOP AND BOTTOM OF THE PLUG AND PULLING 13 REMOVE THE TWO GREEN GROUNDING WIRES FROM THE TOP REAR OF THE BLOWER BY TAKING OUT THE GREEN GROUNDING SCREW WITH A 5 16 NUT DRIVER 14 REMOVE THE BLACK WIRE FROM THE FLAME RECTIFICATION PROBE BY PULLING ON IT 15 REMOVE THE IGNITOR WIRING HARNESS FROM THE CONTROL BOARD BY PRESSING ON THE TABS ON THE TOP AND BOTTO...

Страница 28: ... 200 INCH POUNDS TORQUE IN THE FOLLOWING ORDER 4 REPLACE THE BURNER MOUNTING FLANGE GASKET WITH A NEW GASKET BE SURE THAT BOTH SIDES OF THE GASKET ARE SPRAYED WITH PERMATEX HIGH STACK SPRAY A GASKET ADHESIVE SEALANT PART 99MA 5 RE INSERT THE BBURNER WITH THE FLAT SIDE OF THE FLANGE FACING DOWN 6 REPLACE THE BLOWER OUTLET FLANGE GASKET WITH A NEW GASKET BE SURE THAT BOTH SIDES OF THE GASKET ARE SPR...

Страница 29: ...IRE TOWARDS THE BOTTOM OF THE CONNECTOR 28 RE CONNECT THE AIR INLET PIPING BY LOOSENING THE SMALLER HOSE CLAMP ON THE AIR INLET CONNECTOR ALL THE WAY AND THEN SLIDING THE BOOT OVER THE END OF THE AIR INLET ADAPTER THEN TIGHTEN USING A 5 16 NUT DRIVER 15 SNAP THE AIR ORIFICE INTO THE END OF THE AIR INLET MANIFOLD 16 SLIDE THE AIR INLET ADAPTER OVER THE END OF THE AIR INLET MANIFOLD UNTIL THE STOP I...

Страница 30: ...PAGE 30 PARTS ILLUSTRATIONS ...

Страница 31: ... OFF POWER TO THE SUPER E 2 REMOVE THE DOOR FROM THE SUPER E CABINET 3 SHUT OFF THE GAS VALVE BY TURNING THE BLUE KNOB ON THE VALVE TO THE OFF POSITION 4 SHUT OF THE GAS SUPPLY TO THE VOYAGER 5 BREAK THE UNION ON THE GAS LINE LOCATED BEFORE THE GAS VALVE AND REMOVE THE HALF OF THE UNION THAT IS CONNECTED TO THE GAS VALVE INLET PIPE ...

Страница 32: ...VAILABLE THEN FOLLOW INSTALLATION PROCEDURE 2 IF NO MANOMETERS ARE AVAILABLE USE INSTALLATION PROCEDURE 1 PROCEDURE 1 1 RE CONNECT THE GAS VALVE WIRING HARNESS TO THE GAS VALVE 2 SLIDE THE GAS VALVE BACK INTO POSITION BY PUTTING THE GAS VALVE INLET THROUGH THE GAS VALVE INLET HOLE IN THE LEFT TOP OF THE SUPER E CABINET 3 PLACE THE GAS ORIFICE BACK ON THE BOTTOM HALF OF THE UNION AND TIGHTEN THE UN...

Страница 33: ...GGED INTO THE GAS VALVE AND INTO THE CONTROL BOARD 2 TURN THE ADJUSTMENT SCREW UNDER THE BRASS CAP YOU REMOVED IN STEP 8 ABOVE TURN ONE FULL TURN CLOCKWISE WITH A SMALL FLATHEAD SCREWDRIVER THIS WILL INCREASE THE GAS VOLUME IN THE COMBUSTION PROCESS A IF THE UNIT STILL DOES NOT LIGHT OFF TURN THE ADJUSTMENT SCREW TWO FULL TURNS COUNTERCLOCKWISE 8 REMOVE THE SMALL ROUND BRASS PLUG FROM THE GAS VALV...

Страница 34: ...THE OUTLET PRESSURE TAP PLUG FROM THE RIGHT SIDE OF THE GAS VALVE WITH A 3 16 ALLEN WRENCH 2 PUT THE GAS VALVE ADJUSTMENT SCREW COVER BACK IN PLACE AND TIGHTEN 3 PUT THE VOYAGER CABINET DOOR BACK INTO PLACE B IF IGNITION WAS POOR 1 LOOK AT THE COLOR OF THE FLAME WHILE THE UNIT IS RUNNING THROUGH THE SIGHT GLASS IF IT IS GREEN OR RED IN COLOR OR THE HEATER WHISTLES ON IGNITION TURN THE ADJUSTMENT S...

Страница 35: ...ND BRASS PLUG FROM THE GAS VALVE BY TURNING IT COUNTER CLOCKWISE WITH A SMALL PUNCH AND HAMMER 7 RE CONNECT THE SUPPLY GAS PIPING TO THE VALVE 8 TURN ON THE GAS TO THE SUPER E 9 TURN THE BLUE KNOB ON THE GAS VALVE TO ON 6 CONNECT THE VACUUM HOSE ACCORDING TO THE FOLLOWING DIAGRAM ...

Страница 36: ...DS 10 MORE THAT MANOMETER 1 EXAMPLE MANOMETER 1 READS 35 ADJUST MANOMETER 2 SO THAT IT READS 25 IF THIS DOES NOT STOP THE POOR IGNITION ADJUST THE GAS VALVE ADJUSTMENT SCREW ANOTHER 10 EXAMPLE IF MANOMETER 1 READS 35 MANOMETER 2 SHOULD BE ADJUSTED TO NOW READ 15 15 PUT THE GAS VALVE ADJUSTMENT SCREW COVER BACK IN PLACE AND TIGHTEN 16 REMOVE ALL THE CLEAR VINYL HOSES FROM THE GAS VALVE 17 REMOVE TH...

Страница 37: ... AND CONNECTION OF A BRONZE CIRCULATOR BETWEEN DOMESTIC HOT WATER OUTLET DOMESTIC COLD WATER INLET NOTE IT IS VERY IMPORTANT TO FOLLOW EITHER LOCAL OR FEDERAL PLUMBING CODES WHEN INSTALLING AND OPERATING A MIXING VALVE FOR A DOMESTIC HOT WATER SYSTEM HOW TO SIZETHECOMBINATIONSYSTEM FORRADIANTHEATING IT IS IMPORTANT TO SIZE BOTH HEATING LOAD AND DOMESTIC HOT WATER LOAD IN CHOOSING WHICH SUPER E SSV...

Страница 38: ... IS BASED ON USING THE CIRCULATOR BETWEEN THE DOMESTIC COLD WATER INLET AND THE DOMESTIC HOT WATER OUTLET FOR SET POINT TEMPERATURES ABOVE 120 DEGREES F YOU MUST USE AN ANTI SCALD TEMPERING VALVE ON THE OUT LET TO DOMESTIC HOT WATER FIXTURES VOYAGER FIRST DRAW CAPACITY In minutes AT 140 DEGREES F Model 2 GPM 3 GPM 4 GPM 5 GPM 6 GPM 7 GPM 8 GPM SSVH90 45 20 15 9 7 5 4 3 SSVH130 45 20 16 12 10 9 7 6...

Страница 39: ... USING BUSHINGS INSTEAD OF REDUCING COUPLING OR REDUCING ELBOW VENT CHANGED FROM 3 TO 4 WITHOUT GOING REQUIRED 10 ON BOTH INTAKE AND EXHAUST VENTING NOT CLEANED AND GLUED TOGETHER FOR PRESSURE TIGHT JOINTS INTAKE AIR CONTAINING EXHAUST FROM ANOTHER VENT OR APPLIANCE GAS SUPPLY GAS PRESSURE TOO LOW NEED 7 GAS PRESSURE UP TO 14 GAS PRESSURE GAS METER TOO LOW IN CAPACITY GAS REGULATOR NOT SIZED PROPE...

Страница 40: ...PAGE 40 ...

Отзывы: