Wall installation for size 1 devices
Wall installation for size 2 devices
DANGER
The ground continuity between the base of the device and the bracket is ensured by the special
component shown in the figure. Install this component and verify the ground continuity between the
bracket and the base of the device at the end of the installation.
Alternatively, it is possible to drill the aluminum base in the area where the four special fixing holes are.
The fixing screws must be equipped with O-rings to guarantee the protection rating.