![Nastec MIDA 203 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/nastec/mida-203/mida-203_installation-use-and-maintenance-handbook_707879011.webp)
WARNING
The manufacturer declines all responsibility for damage to the product due to transport
4.3. Handling
The product must be handled by hand or using suitable lifting equipment in relation to its weight and the regulations
in force.
If necessary, use dedicated handling equipment (cranes, ropes, trolleys), using the lifting points provided in the
product.
During handling it is recommended to:
• Handle with care
• keep away from suspended loads
• always wear accident prevention equipment
• be careful not to damage electrical cables
Do not handle the product using electrical cables as lifting gear.
WARNING
Failure to follow the instructions may result in damage to the product, the system in which it is
installed and, in the worst cases, damage to property or persons with even fatal consequences.
4.4. Storage
The product must be stored in its packaging in a dry place, without sudden changes in humidity and temperature
and protected from mechanical (weights, vibrations), thermal and chemical agents.
The temperature of the storage environment must be between -20°C (-4°F) and 70°C (+158°F) with a maximum
relative humidity of 85% (non-condensing).
If the product remains in stock for more than 24 months from the manufacturing date shown on the packaging, it is
necessary to check the mechanical integrity of its parts and supply power to it at least once every 12 months.
If the product is put back into storage after it has been used, it is advisable to contact the manufacturer for further
information on storage.
TIP
For more information contact the dealer or technical support at [email protected] or by opening a
support ticket on the portal service.nastec.eu
5. Technical features
5.1. Name
MIDA ABCD - EFGH
•
MIDA
:Product name
•
A
: Nominal AC supply voltage (2 =1x230 VAC, 3 = 3x230 VAC, 4 = 3x400 VAC)
•
BCD
Rated output current
•
EF
: Customization code (01 = standard customization)
•
G
: Mounting kit included in the package (0 = none, 1 = motor, 2 = wall, 3 = motor+wall)
•
H
: Pressure sensor included in the package (0 = none, 1 = pressure sensor 0-16 bar)
5.2. Technical Data
Electrical specifications by model:
Model
Vin +/- 15% [VAC]
Max V out [VAC]
Max I in
[A]
Max I out
[A]
Typical
motor P2
[kW]
Maximum
efficiency [%]
Size
MIDA 203
1 x 230
3 x Vin
4,5
3
0,55
94,5
1
MIDA 205
1 x 230
3 x Vin
7,5
5
1,1
94
1
MIDA
11