E8 Swing Automatic Gate. Revision 1.1.8 –1112
9 of 19
Control Panel – Model D1
The E8 D1 control panel is specially designed to match 12Vdc Arm Gate Motor(s).
The electronic panel requires no maintenance as long as the gate operates in proper
order and is kept dry and insect free. Mount the Control box as close to the motor(s)
(maximum 10m cable) as possible connected with minimum 1.5mm 2-core electrical
cable to reduce any voltage drop which will affect the performance of the system.
2.5mm to 4mm house cable is commonly used.
DIP SWITCH setting on the control board:
[1]
ON
= Delay Close motor A (MT A) for 2 seconds after MT B
- used in conjunction with solenoid lock
[1]
OFF
= Gate(s) open/close at same time
[2]
ON
= Small Reverse before opening used with 12V lock
[2]
OFF
= Gates open immediately without small reverse movement
[3]
OFF &
[4]
OFF
= LAMP ON (gate open) & cut off 1 min. after gate closed
[3]
ON
=
LAMP permanently ON when Photocell detect dark ambient.
LAMP OFF, 1 minute after photocell detect bright ambient
[4]
ON
= LAMP output can be ON/OFF manually. Pressing [1-SIDE]
[COM] will toggle LAMP output.
Note : Single Arm operation no longer possible when DIP 4 is
ON
[5]
ON
=
Single Gate Operation
(MT A)
[6]
OFF
= Not in use
[7]
OFF &
[8]
OFF
= Disable Auto Close
[7]
OFF &
[8]
ON
= 030 sec. Auto Close
[7]
ON &
[8]
OFF
= 060 sec. Auto Close
[7]
ON &
[8]
ON
= 120 sec. Auto Close
On Solar Setup
For Solar powered setup, keep both DIP #3 and DIP #4 to [OFF] position.