E8 Swing Automatic Gate. Revision 1.1.8 –1112
12 of 19
Remote Control:
The 12Vdc remote transmitter contains two signal represented by
button 1 and button 2 on your remotes. Confirm with owner which function they want
for each of the button.
Double gate setup button #1 can be set as single gate operation while button #2 is set
as double gate operation.
You can change this so that either button will activate BOTH gates by joining the
Yellow and the Brown wire at [2 SIDE] terminal.
You can relocate the receiver black box to another
moisture-free
location to increase
signal strength using cat.5 network cable.
Antenna:
The green/blue wire is the antenna with a tuned length. DO NOT CUT.
You can increase the range by installing an additional long range antenna connected
to the green wire.
Adding New Remotes:
Remove the back panel of a remote (tiny Phillips screw) that is already working to
activate your gate. Match the new remote receiver DIP setting to the current remote
DIP switch setting.
Each DIP switch has 3 positions (top, middle and bottom) so care must be taken when
setting each DIP switch.
Check the signal transmission by pressing your new remote.
Changing Remote Codes:
The black Remote receiver Box has 5 wires connecting to your control board.
Remove the lid to view the code DIP switches.
If you change these you must also change all your remote DIP switches by removing
the back panel of each remote and match to the receiver DIP setting. Each switch has
3 positions (top, middle and bottom) so care must be taken when setting each DIP
switch. After the receiver panel is connected to the control panel, check signal
transmission. Test each of the remote individually.
Increase Range of the Remotes:
Connect a Long Range Antenna to the end of the green / blue antenna wire of the
receiver box. Place as high as possible in sight of the area you wish to transmit from.
You can relocate the transmitter box to another
moisture-free
location to increase
signal strength using cat.5 network cable.