E8 Swing Automatic Gate. Revision 1.1.8 –1112
16 of 19
Problem:
The gate will open but not close.
Solution:
Check the wire loop is still in place on {IR Beam} block between terminal
[NC] and [COM].
If photobeams are fitted, check beam wiring/setup/ obstructions.
Problem:
The gate does not travel smoothly when opening or closing.
Solution:
Ensure there is no obstruction to the movement of the gate such as hitting the
ground. This can be verified by releasing the gate to Emergency release mode.
Manually swing the gate open / close to detect any tight spots.
Ensure that the gate is properly leveled and that the dimension guide for the
installation of the Automatic gate is followed.
Arm actuators
must not be
parallel to the gate when fully open or fully closed.
Problem:
On double gate setup, one gate closes fully before the 2
nd
gate starts.
Solution:
System is running on battery only (eg. Solar setup) and transformer AC not
connected. Check power with voltmeter.
(does not apply to Version 1.3.0 chip. In Version 1.3.0 chip both gates will always
close simultaneously even when running on Battery mode)