20
NARVON
5. Take out the auger and remove the seal (A).
7.4. Washing and sanitizing the
components
All of the previously disassembled and removed components
must be thoroughly washed and sanitized.
Important: the sanitizing solution must
comply with the regulations enforced at the
time the machine is used.
To carry out the procedure correctly, please use the
following instructions:
1. Fill a container with a sanitizer solution mixed in water
(2% of sodium hypoclorite mixed in water).
2. Thoroughly wash the tank, lid and evaporator with a
sponge soaked in the sanitizer solution.
3. Thoroughly wash again with clean water.
4. Fill another container with a sanitizer solution.
5. Dip the dismantled components into the sanitizer solution.
6. Leave the dismantled components to soak in the solution
for 30 minutes.
7. Thoroughly wash again with clean water.
8. Place the components on a clean surface and dry them.
9. Assemble the machine as described in Section 7.5.
10. Before using the machine again, run the rinsing
cycle with clean water (Section 7.6).
Warning: Do not submerge lids equipped
with lighting in any type of liquid. Before
starting the cleaning and sanitizing
operations of the lid, remove it from the
machine as described in the previous
chapter.
To clean the lighted lid correctly, proceed as follows;
1. Using a clean, damp cloth, first wipe clean the bottom
part of the lid (in contact with the product);
2. Using a clean, damp cloth, wipe clean the whole outer
part;
3. Using a sponge dipped in sanitising solution, sanitise the
bottom part of the lid, taking care not to wetz the
contacts (X);
4. Allow to process for 30 minutes;
5. Rinse only the bottom part at least twice with a clean
sponge soaked in fresh water.
6. Place the lid on a clean surface and dry it; first dry the
bottom and then the outer part with a clean cloth.
7. Set the lid back in place only after having cleaned and
sanitised the bowl.
It is forbidden to wash and/or sanitise the lid
while it is installed in the machine.
7.5. Reassembling the washed
components.
All of the washed and sanitized components must be
carefully reassembled. Some components must be
adequately lubricated in order to ensure that they work
efficiently.
Apply the seal (A) on the auger as shown in the Fig.37.
A
Fig.35
Fig.36
X
Fig.37
Bottom Part