17
EN INSTALLATION AND OPERATING INSTRUCTIONS
min. 20
B
A
E
D
C
255
12
5
125
112
min 30
0
Figure 1. Minimal safety clearances for the heater.
Figure 2.
3. INSTALLATION
– Fasten the mounting plate to the wall with the
screws which follow the delivery according to
the picture 2.
NM, NS: change from right to left hand
(only if necessary)
Note! If you want to change from right to left
hand work according to Stages 1, 2 and 3. If there
is no need to change move to Stage 4.
Stage 1:
– Loosen the anchor screws of the coupling box.
– Gently pull of the adjusters, and open the two
outermost screws that are attached to the
control panel and found under the adjusters.
It is important that the screws are the same in
fastening.
– Open the optional adjuster’s cover plate’s
screws which are on the other side of the
junction box (Figure 3).
Stage 2:
– Unscrew the attaching screw connecting the
middle resistor and the terminal block which is
located at the bottom of the junction box. This
will enable you to turn the leg of the terminal
block to the side from underneath the screw
(Figure 4).
Stage 3:
– Turn the adjusting module carefully around
with its cords attached and install the axis of
the adjuster through the holes on the other side
of the junction box.
– Screw together the terminal block and the
cover plate of the optional adjusters facing
each other.
– Finally, attach the bottom plate of the junction
box and adjusters to their place (Figure 5).
Bild 3.
Bild 4.
Bild 5.