English
15
Technical Specification
Cordless drill screwdriver:
Model
ASV 10-2A
Voltage.
.
10.8.V
Idle.speed:.
1st.range.
0–50.min
-1
.
.
nd.range.
0–1.50.min
-1
Maximum.torque:.
soft.material.(wood).
14.Nm
.
.
hard.material.(metal).
.Nm
Chuck.–.scope.of.clamping.
.
0.8–10.mm
Wood.screws.
.
max.ø.5.mm
Drilling:.
into.metal.
max.ø.10.mm
.
.
into.wood.
max.ø.0.mm
Threaded.spindle.for.chuck.
.
3/8“.-.4.UNF
Weight.w/o.accumulators.
.
0.95.kg
Charger:
Model
AN 10 E
Input.voltage.
.
0–40.V
Frequency.
.
50–60.Hz
Power.input.
.
80.W
Output.voltage.
.
1.6.V
Charging.current.
.
6.A
Weight.
.
0.4.kg
Class.of.protection.
.
II./.
Accumulator:
Model
AP 10 LE
Voltage.
.
10.8.V
Capacity.
.
1.5.Ah
Cell.type.
.
Li-Ion
Temperature.of.charging.
.
4.5–40.5.°C
Charge.time:.
capacity.-.75.%.
cca..15.min
.
.
capacity.-.100.%.
cca..5.min
Weight.
.
0.19.kg
Description:
1 ............Accumulator
2 ............Accumulator clamp
3 ............Switching
4 ............Reversing switch
5 ............Speed changing switch
6 ............Adjusting ring for torque setting
7 ............Chuck clamp sleeve
8 ............Charger LEDs
9 ............Charger
Scope of use
The cordless drill screwdrivers are specified for drilling into metals,
woods and plastics and for screwing.
Double insulation
To ensure maximum safety of the user our tools are designed and built
to satisfy applicable European standards (EN standards). Tools with
double insulation are marked by the international symbol of a double
square. These tools must not be grounded and a two-wire cable is suf-
ficient to supply them with power. Tools are shielded in accordance with
EN 55014.
Charging battery pack instructions
1. Make sure power circuit voltage is the same as that shown on the
charger specification plate. Connect charger (9) to power source.
Red light should light up. This indicates the charger is ready to be-
gin charging.
2. Position the accumulator/battery pack (1) into the charger as far as
the stop, see the Fig.
3. The red light is on and the green light begins to blink, indicating
that the battery pack is receiving a “Fast Charge”.
4. Once the green light begins to light continuously, the battery pack
is ready for use. If the battery pack stays in the charger, the charger
continues in slow charging until the battery pack is fully charged.
5. Take out the accumulator and disconnect the charger (unless you
want to charge another accumulator or let the accumulator in the
slow charging mode before you will use it).
New accumulators:
During the first cycles of charging capacity of the new accumulator can
be lower than the rated value, namely due to the fact that chemical ac-
cumulator composition has not been activated yet. This state is of tem-
porary nature and will be compensated after a few cycles of charging.
Note:
• Disconnect charger from power source when not in use.
Survey of charger LED signals:
green LED
red LED
meaning of signal
combination
is off
is on
connected to power
supply
flashes
is on
battery pack is under
charge
is on
is on
battery pack is charged
is off
flashes
battery pack is damaged
flashes
flashes
the battery is too hot/cold