6. Replace and re-secure both burners  ensuring that the venturis fit over the burner orifices. 

7.

 Remove the pilot hood from the pilot assembly by pulling vertically. Use an Allen key to unscrew the injector. Replace the 

pilot injector with the one supplied. Re-assemble the pilot hood onto the assembly ensuring key position for proper alignment.

8.

  To convert the main valve to the desired fuel, follow the valve access instructions and leaflet for the SIT step motor 

assembly that is included with this kit. (Refer to your installation manual for instructions) 

9.

  The conversion data label must be filled out and attached adjacent to the valve.

10.

 Turn on the gas supply and check for gas leaks by brushing on a soap and water solution. Do not use open flame.

11

. Re-install the log set/glass. Then light the pilot and main burner to ensure that the gas lines have been purged.  Refer to 

the lighting instructions in your fireplace installation manual.

12

.  Re-secure the door.  Turn on the electrical supply to the appliance.

Purge all gas lines with the glass door off. 

Ensure that a continuous flow is at the burner before replacing the door.

Adjust the pilot screw to provide properly sized flame. Turn in a 

clockwise direction to reduce the gas flow.
Inlet pressure can be checked by turning screw (A) counter-

clockwise until loosened and then placing pressure gauge tubing 

over the test point. Gauge should read 7” (minimum 4.5”) water 

column for natural gas or 13” (11” minimum) water column for 

propane. Check that main burner is operating on “HI”.
Outlet pressure can be checked the same as above using screw (B). 

Gauge should read 3.5” water column for natural gas or 10” water 

column for propane. Check that main burner is operating on “HI”.
AFTER TAKING PRESSURE READINGS, TIGHTEN SCREWS 

FIRMLY TO SEAL. DO NOT OVER TORQUE.

LEAK TEST

 

ADJUSTMENTS

VENTURI ADJUSTMENT

Air shutter adjustment must be done by a qualified 

installer!

Air shutters have been factory set open according to the chart below:  

These setting are for (maximum) horizontal termination.

Closing the air shutter will cause a 

more yellow flame, but can lead to 

carboning.  Opening the air shutter 

will cause a more blue flame, but 

can cause flame lifting from the 

burner ports.  The flame may not 

appear yellow immediately; allow 

15 to 30 minutes for the final flame 

colour to be established. 

Adjustment may be required depending on fuel type, vent configuration 

and altitude.

FLAME CHARACTERISTICS

PRESSURE ADJUSTMENT

P

NG

B81G

7/16”

3/16”

B81L

7/16”

3/16”

B81S

7/16”

3/16”

It’s important to periodically perform a visual check of the pilot and 

burner flames. 

Compare them to the illustrations provided. 

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada        •  (705)721-1212         •  fax (705)720-9081       • www.napoleonfireplaces.com

W415-0956 / A / 12.09.16

HOOD

PILOT

ORIFICE

CAPUCHON DE 

LA VEILLEUSE

INJECTEUR DE 

VEILLEUSE

PILOT 

BURNER

FLAME MUST ENVELOP 

UPPER 3/8” TO 1/2” OF

FLAME SENSOR 

FLAME

SENSOR

ELECTRODE

Maximum Input Ratings:
 

     NG 

      60,000 BTU/hr      50,000 BTU/hr

AIR SHUTTER 

OPENING

ORIFICE

VENTURI 

BURNER

A

B

PILOT SCREW

Содержание W175-0308 NG TO P

Страница 1: ...und replace with the orifices supplied 5 Before replacing the burners adjust the air shutters according to the table located on the back of this page Continued on reverse This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructionsandallapplicablecodesandrequirementsoftheauthorityhavingjurisdiction Iftheinformation in these instructions is...

Страница 2: ...water column for natural gas or 13 11 minimum water column for propane Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST ADJUSTMENT...

Страница 3: ...NS DOIVENT ÊTRE GARDÉES PAR LE PROPRIÉTAIRE VEUILLEZ COCHER LES CASES POUR INDIQUER QUE LES ÉTAPES CORRESPONDANTES ONT ÉTÉ COMPLÉTÉES ENSEMBLES DE CONVERSION POUR LES BRÛLEURS B81L B81G B81S Cet ensemble de conversion doit être installé par une agence d entretien qualifiée conformément aux instructions du fabricant et à tous les codes et les exigences des autorités compétentes Si ces instructions ...

Страница 4: ...pection visuelle de la flamme de la veilleuse et du brûleur Comparez la à ces illustrations 7 Retirez la hotte de dérivation de flamme de l assemblage de la veilleuse en tirant à la verticale Utilisez une clé Allen pour dévisser l injecteur Remplacer l injecteur par celui qui est fourni Replacez la hotte de dérivation de flamme sur l assemblage de la veilleuse en vous assurant qu elle soit bien al...

Отзывы: