EN
W415-1367 / B / 01.09.19
7
general information
1.1 dimensions
1 1/4"
32mm
30 11/16"
779mm
5 1/2"
140mm
12"
305mm
6 3/4"
171mm
1 1/4"
32mm
14" 356mm
7"
178mm
3" 76mm DIA.
5" 127mm DIA.
ELECTRICAL
INLET
GAS
INLET
SAFETY
BARRIER
43 3/4"
1111mm
37 3/4"
959mm
TITLE:
RATING PLATE
GT8 (SB)
REVISION: A:
UPDATED CSA DATE & DESCRIPTION; UPDATED “FIREPLACE” TO “APPLIANCE” || 09.11.17_C.L.
LABEL #:
W385-1981
DATE:
09.17.14
W385-1981 / A
GT8
SERIAL NUMBER:
PAGE 1 OF 2
WOLF STEEL LTD.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
DIRECT VENT GAS APPLIANCE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE
HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE
HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR,
PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.
FOR USE ONLY WITH BARRIER W565-0187. FOLLOW THE INSTALLATION
INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
GT8N MODEL GT8P
(NATURAL GAS) (PROPANE)
0-4500FT (0-1370m) ALTITUDE 0-4500FT
(0-1370m)
6,000 BTU/h INPUT 6,000BTU/h
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
WARNING:
DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT WITH
THE FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 6"
RECESSED DEPTH
7"
FLOOR 0"
VENT TOP
2"
SIDES
0"
VENT SIDES & BOTTOM
1"
BACK
1 1/2"
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS
ARE 4 INCHES AND 10 FEET RESPECTIVELY.
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS
ARE 36 INCHES AND 10 FEET RESPECTIVELY.
VENTED DECORATIVE GAS APPLIANCE NOT FOR USE WITH SOLID FUEL. FOR
USE WITH GLASS DOOR. CERTIFIED WITH THIS UNIT ONLY.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT
KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
VENT-AIR INTAKE SYSTEM.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE
RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY
LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT
PROHIBITED BY LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A
CERTIFIED KIT IS USED.SYSTEM.
MATERIAL:
CLASS IIIA-2 PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
SPECIFICATIONS:
BLACK ON WHITE BACKGROUND, HOLE TO BE 1/4” DIAMETER.
MAX OVERALL DECAL SIZE:
3.500" x 6.000"
SERIAL NUMBER TO BE ASCENDING FROM
GT8004749
CONFORMS TO ANSI Z21.50-2016, CERTIFIED TO CSA 2.22-2016 VENTED DECORATIVE GAS APPLIANCE
A
A
A
A
A
RATING LABEL LOCATION: THE RATING LABEL IS LOCATED UNDER THE CONTROL PANEL AND IS
CHAINED TO THE APPLIANCE. DO NOT REMOVE.
SAMPLE
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
1.2 rating plate information