17
W415-0695 / 05.12.08
FIGURE 28
GAS INSTALLATION
This appliance may be installed as an OEM (Original Equipment Manufacturer) Installation in a manufactured home or mobile home and
must be installed in accordance with the manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for
use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance.
This Mobile/Manufactured Home listed appliance comes factory equipped with means to secure the unit.
The fi replace is equipped with two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installations,
the fi replace must be fastened in place. Use #10 screws, inserted through the holes in the base to secure.
Always turn off the pilot and the fuel supply at the source, prior to moving the mobile home.
After moving the mobile home and prior to lighting the fireplace, permanently ensure that the logs are positioned correctly.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by
local codes.
This appliance is only to be used with the type of gas indicated on the rating plate. This appliance is not convertible for use
with other gasses, unless a certifi ed kit is used.
CONVERSION KITS
The mobile home appliance is fi eld convertible between Natural Gas (NG) and Propane (LP).
To convert from one gas to another consult your Authorized dealer/distributor.
MOBILE HOME INSTALLATION
7.
Apply a heavy bead of waterproof caulking 2“ above the fl ashing. Slide the storm collar around the air ter-
minal and down to the caulking. Tighten to ensure that a weather-tight seal between the air terminal and the
collar is achieved. Attach the other storm collar centred between the air intake and air exhaust slots onto the
air terminal. Tighten securely. Attach the rain cap.
8.
Continue adding rigid venting sections, sealing and securing as above. Attach a 5” collapsed telescopic
pipe to the last section of rigid piping. Secure with screws and seal. Repeat using a 8” telescopic pipe.
9.
Run a bead of high temperature sealant Mill Pac W573-0007 (not supplied) around the outside of
the 5” collar on the fi replace. Pull the adjustable pipe a minimum of 2” onto the collar. Secure with 3
screws. Repeat with the 8” telescopic pipe.
10.
In the attic, slide the vent pipe collar down to cover up the open end of the shield and tighten. This will prevent any materials, such as
insulation, from fi lling up the 1” air space around the pipe.
FIGURE 29
FIGURE 30
Proceed once the vent installation is complete.
NOTE: All gas connections must be contained within the fireplace when complete.
1.
The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off
valve, and an 18” listed fl exible gas connector.
2.
The access to the gas inlet is located on the right side of the outer shell.
3.
To ease the connection, the shut off can be fl exed out through the side of the fi replace
where the connection can be made and then returned into the shell.
4.
When fl exing any gas line, support the gas valve so that the lines are not bent.
(See Access Pg. 20).
5.
Check for gas leaks by brushing on a soap and water solution.
Do not use open flame.
Purge all gas lines with the glass door of the fireplace open. Assure that a continuous gas flow
is at the burner before closing the door.
Vertical terminations may display a very active fl ame. If this appearance is not desir-
able, the vent exit must be restricted using restrictor plate, W500-0205. This reduces
the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more
traditional appearance.
The plate has a series of holes to allow for adjustment.
Remove the two screws on either side of the exhaust collar inside the fi rebox. Install
the plate in the desired set of holes, then replace the screws.
RESTRICTING VERTICAL VENTS
RESTRICTOR PLATE
TOP OF THE
FIREBOX
FLUE COLLAR
FIGURE 31
Содержание Madison GD80NT
Страница 1: ...1 W415 0695 05 12 08 10 00 W415 0695 05 12 08...
Страница 4: ...4 W415 0695 05 12 08 FIGURE 1 INSTALLATION OVERVIEW FIREPLACE DIMENSIONS FIGURE 2...
Страница 12: ...12 W415 0695 05 12 08 MINIMUM AIR TERMINAL LOCATION CLEARANCES GD 301 FIGURE 13...
Страница 35: ...35 W415 0695 05 12 08...
Страница 39: ...39 W415 0695 05 12 08 NOTES...
Страница 40: ...40 W415 0695 05 12 08 NOTES...