16

W415-0695 / 05.12.08

FIGURE 24

The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel support 
ring assembly or equivalent noncombustible strapping to maintain the minimum clearance to combustibles for both vertical 
and horizontal runs. 

All inner exhaust and outer intake vent pipe joists may be sealed using either red high temperature silicone sealant  
W573-0002  or black high temperature Mill Pac W573-0007 with the exception of  the fireplace exhaust flue collar 
which must be sealed using Mill Pac (not supplied).

FIGURE 25

USING RIGID VENT COMPONENTS

HORIZONTAL AIR TERMINAL INSTALLATION

FIGURE 26

VERTICAL VENTING INSTALLATION

FIGURE 27

1. 

Move the fi replace into position.

2. 

Fasten the roof support to the roof using the screws provided. The roof support is optional. In 

this case the venting is to be adequately supported using either an alternate method suitable to 
the authority having jurisdiction or the optional roof support. 

3.

 Apply high temperature sealant W573-0002 (not supplied) to the outer edge of the inner 

sleeve of the air terminal. Slip a 5” diameter coupler a minimum of 2” over the sleeve and 
secure using 3 screws. 

4

.

 Apply high temperature sealant W573-0002 (not supplied) to the outer edge of the of the outside sleeve of 

the air terminal. Slip a 8” diameter coupler over the sleeve and secure as before. Trim the 8” coupler even with 
the 5” coupler end.

5.

 Thread the air terminal pipe assembly down through the roof  support and attach, ensuring that a minimum 16” 

of air terminal will penetrate the roof when fastened. 

If the attic space is tight, we recommend threading the 

Wolf Steel vent pipe collar or equivalent loosely onto the air terminal assembly as it is passed through 
the attic. 

The air terminal must be located vertically and plumb. 

6.

 Remove nails from the shingles, above and to the sides of the chimney. Place the fl ashing over the air terminal 

and slide it underneath the sides and upper edge of the shingles. Ensure that the air terminal is properly centred 
within the fl ashing, giving a 3/4” margin all around. Fasten to the roof. Do NOT nail through the lower portion of the fl ashing. Make 
weather-tight by sealing with caulking. Where possible, cover the sides and top edges of the fl ashing with roofi ng material. 

EXTENDED HORIZONTAL AIR TERMINAL INSTALLATION

1. 

Move the fi replace into position. Measure the vent length 

required between terminal and fi replace taking into account 
the additional length needed for the fi nished wall surface and 
any 1¼” overlaps between venting components.

2. 

Apply high temperature sealant W573-0007 (not sup-

plied) to the outer edge of the 5” inner collar of the fi replace.  
Attach the fi rst vent component and secure using 3 self tap-
ping screws. Repeat using 8” piping.  

3. 

Holding the air terminal insert the terminal into both vent 

pipes with a twisting motion to ensure that both the terminal 
sleeves engage into the vent pipes and sealant. Secure the 
terminal to the exterior wall and make weather tight by sealing 
with caulking (not supplied). 

 

1. 

Follow the instructions for “Horizontal Air Terminal Installations”, items 1 to 3. 

2. 

Continue adding components alternating inner and outer venting. Ensure that all 5” 

venting and elbows have suffi cient vent spacers attached and each  component is securely 
fastened to the one prior. Attach the 5” telescopic sleeve to the vent run. 

Repeat using a 8” telescopic sleeve. Secure and seal as before. To facilitate completion, 
attach 5” and 8” couplers to the air terminal. 

3.

 Install the air terminal. 

See item 3 of the Horizontal Air Terminal Installation.

 Extend the 5” 

telescopic sleeve; connect to the air terminal assembly. Fasten with self tapping screws and seal. 
Repeat using the 8” telescopic sleeve.

Содержание Madison GD80NT

Страница 1: ...1 W415 0695 05 12 08 10 00 W415 0695 05 12 08...

Страница 2: ...Clothing or other flammable material should not be placed on or near the fireplace Due to high temperatures the fireplace should be located out of traffic and away from furniture and draperies Ensure...

Страница 3: ...y This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasive and chemical cleaners nor chip ping on porcelain enamel parts mechanical b...

Страница 4: ...4 W415 0695 05 12 08 FIGURE 1 INSTALLATION OVERVIEW FIREPLACE DIMENSIONS FIGURE 2...

Страница 5: ...r obstruct the front opening of the fireplace Objects placed in front of the fireplace must be kept a minimum of 48 from the front face of the unit Minimum clearance to combustible construction from f...

Страница 6: ...WALL TERMINAL KIT GD422R or 1 12 TO 7 12 PITCH ROOF TERMINAL KIT GD410 8 12 TO 12 12 ROOF TERMINAL KIT GD411 FLAT ROOF TERMINAL KIT GD412 or PERISCOPE KIT GD401 for wall penetration below grade With e...

Страница 7: ...nch up on horizontal or vertical runs and elbows Keep it pulled tight A 1 air gap between the inner and outer liner all around is required for safe operation Vent lengths that pass through unheated sp...

Страница 8: ...T VT 40 feet 20 9 40 Since both formulas are met this vent con guration is acceptable FIGURE 5 90 H1 V2 H2 V1 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acc...

Страница 9: ...1 HT 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4 ft V2 1 5 ft VT V1 V2 4 1 5 5 5 ft H1 2 ft H2 1 ft H3 1 ft H4 1 5 ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8...

Страница 10: ...Formula 1 HT VT Formula 2 HT VT 40 feet Simple venting con gurations See graph to determine the required vertical rise VT for the required horizontal run HT VERTICAL TERMINATION V1 5 ft V2 10 ft VT V1...

Страница 11: ...8 8 1 16 1 ft HT VT 16 1 4 5 20 6 ft Formula 1 HT 3VT 3VT 3 x 4 5 13 5 ft 16 1 13 5 Since this formula is not met this vent con guration is unacceptable Formula 2 HT VT 40 feet 20 6 40 Since only form...

Страница 12: ...12 W415 0695 05 12 08 MINIMUM AIR TERMINAL LOCATION CLEARANCES GD 301 FIGURE 13...

Страница 13: ...upport 2 Apply a bead of caulking not supplied to the framework or to the Wolf Steel vent pipe shield plate or equivalent in the case of a nished ceiling and secure over the opening in the ceiling A r...

Страница 14: ...ion air collar and secure with 3 8 screws 7 If more liner needs to be used to reach the replace couple them together as illustrated The vent system must be supported approximately every 3 feet for bot...

Страница 15: ...s properly centred within the ashing giving a 3 4 margin all around Fasten to the roof Do not nail through the lower portion of the ashing Make weather tight by sealing with caulking Where possible co...

Страница 16: ...c The air terminal must be located vertically and plumb 6 Remove nails from the shingles above and to the sides of the chimney Place the ashing over the air terminal and slide it underneath the sides...

Страница 17: ...d air exhaust slots onto the air terminal Tighten securely Attach the rain cap 8 Continue adding rigid venting sections sealing and securing as above Attach a 5 collapsed telescopic pipe to the last s...

Страница 18: ...arance to combustibles is maintained within the cavity It is not necessary to install a hearth extension but the replace should be raised to be ush with either the hearth or the nished oor When roughi...

Страница 19: ...72 MINIMUM ENCLOSURE HEIGHT Do not build into this area it must be left clear to provide adequate clearance for the vent in this 14 wide area centered along the front of the fireplace No combustibles...

Страница 20: ...such as cement board ceramic tile marble etc when nishing to the replace DO NOT USE WOOD OR DRYWALL Facing and or nishing material must never overhang into the replace opening Do not distort or force...

Страница 21: ...W415 0695 05 12 08 FIGURE 40a Combustible mantel clearance can vary according to the mantel depth Use the graph to help evaluate the clear ance needed FIGURE 40b MINIMUM MANTEL AND ENCLOSURE CLEARANC...

Страница 22: ...be re installed before operating the unit It is necessary to hard wire this fireplace Permanently framing the replace with an enclosure requires the replace junction box to be hardwired This replace m...

Страница 23: ...ht left and centre hearth bricks into the rebox as illustrated The hearth should appear seamless across the front Ensure that a space exists between the hearth bricks and the perimeter of the burner 5...

Страница 24: ...he PHAZERAMIC burner 2 Position log 2 onto the locators on the PHAZERAMIC burner 3 Position the slot on the bottom of log 3 onto the bracket shown with the charred face of the log to the front LOG PLA...

Страница 25: ...ended The burner has been designed to achieve maximum glow without embers Charcoal provided could be randomly placed on the bre hearth on both sides of the burner and across the front especially at th...

Страница 26: ...ng Lift the hearth strip up and away from the front of the replace The glass door is secured to the top front edge of the rebox Pull the handle of the latch forward then lift the hook out from the slo...

Страница 27: ...ower The blower is pre wired and is controlled by the remote control supplied with the unit For control details see operation Drywall dust will penetrate into the blower bearings caus ing irreparable...

Страница 28: ...n away from magnet catch 2 Remove the hearth strip by lifting up and away from unit 3 Remove the receiver by pulling the left side of the plate away from the bracket 4 Once disengaged pull the wiring...

Страница 29: ...ansmitter The system is now initialized TEMPERATURE DISPLAY 1 Press the ON OFF key on the transmitter The transmitter display will show all active icons on the screen At the same time the receiver con...

Страница 30: ...evels With the system on and the ame level at the maximum press the Down Arrow Key once and it will reduce the ame height by one step until the ame is turned off The Up Arrow Key will increase the ame...

Страница 31: ...function to control the replace during a power failure If the receiver is not equipped with back up batteries the blower and night light features will not operate during a power failure The receiver...

Страница 32: ...der water Warning if you do not follow these instructions exactly a re or explosion may result causing property damage personal injury or loss of life Initial lighting of the pilot and main burners mu...

Страница 33: ...can cause improper and dangerous operation Verify proper operation after servicing This replace and its venting system should be inspected before use and at least annually by a quali ed service person...

Страница 34: ...60 W175 0260 CONVERSION KIT NG TO LP 61 W175 0261 CONVERSION KIT LP TO NG 62 FK80 R FRAMING KIT RECTANGULAR 63 FK80 A FRAMING KIT ARCHED 64 DK80A HC DECORATIVE DOORS HAMMERED COPPER ARCHED 65 DK80R H...

Страница 35: ...35 W415 0695 05 12 08...

Страница 36: ...ed as required Incorrect installation refer to Figure 13 to ensure correct location of storm collars Flames are con sistently too large or too small Carboning occurs check pressure readings Inlet pres...

Страница 37: ...ve Reconnect replace thermopile valve Remote wall switch wire is too long too much resistance in the system shorten wire to correct length or wire gauge Faulty thermostat or switch replace Pilot will...

Страница 38: ...38 W415 0695 05 12 08 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 39: ...39 W415 0695 05 12 08 NOTES...

Страница 40: ...40 W415 0695 05 12 08 NOTES...

Отзывы: