EN
W415-1426 / D / 05.22.19
5
standard checklist
1.0 general information
Installer, please fi ll out the following information:
Customer:
_____________________________________________________________________
Address: _____________________________________________________________________
Date of Installation:
_____________________________________________________________________
Location of Appliance:
_____________________________________________________________________
Installer:
_____________________________________________________________________
Dealer/Distributor
Contact Number:
_____________________________________________________________________
Serial
#:
_____________________________________________________________________
Model:
Natural
Gas:
Propane:
GDS28-1NSB
GS28N
GDS28-1PSB
GS28P
When the appliance is installed at elevations above 4,500 ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000 ft (305m).
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion /
contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance may be installed in an aftermarket permanently located, manufactured mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certifi ed kit is used.
This appliance is approved for bedroom and bed-sitting room installations.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can
be improved if the assembly is warmed, using a hair dryer or similar heat source. The protective wrap must be
removed before operating the appliance.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and
must be installed.
GDS28
GS28
NG
P
NG
P
Altitude (FT)
0-4,500
0-4500
0-4500
0-4500
Max. Input (BTU/HR)
30,000
26,000
30,000
26,000
Max. Output (BTU/HR)
25,500
22,360
24,600
21,600
Max. Steady State
Effi ciency (w/the fan on)
85%
86%
82%
83%
Min. Inlet Gas Supply
Pressure
4.5" (11mb) Water
Column
11" (27mb)
Water Column
4.5" (11mb) Water
Column
11" (27mb)
Water Column
Max. Inlet Gas Supply
Pressure
7" (17mb) *
Water Column
13" (32mb) Water
Column
7" (17mb) *
Water Column
13" (32mb) Water
Column
Manifold Pressure
(Under Flow Conditions)
3.5" (9mb)Water
Column
10" (25mb)
Water Column
3.5" (9mb)Water
Column
10" (25mb)
Water Column
1.1
rates and effi ciencies
* Max. inlet pressure not to exceed 13".