19
W415-0807 / C / 09.02.16
!
WARNING
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
WITH THE GLASS DOOR OPEN OR REMOVED.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
10.0 TROUBLESHOOTING
SYMPTOM
PROBLEM
TEST SOLUTION
Main burner goes out; pilot
stays on.
Pilot fl ame is not large enough
or not engulfi ng the thermo-
pile.
-
Turn up the pilot fl ame.
-
Replace pilot assembly.
Thermopile shorting.
-
Clean thermopile connection tot he valve. Reconnect.
-
Replace thermopile / valve.
Remote wall switch wire is too
long; too much resistance in
the system.
-
Shorten wire to connect length or wire gauge.
Faulty thermostat or switch.
-
Replace.
Main burner goes out; pilot
goes out.
Refer to “MAIN BURNER GOES OUT; PILOT STAYS ON”
Pilot goes out when the
gas knob is released.
The gas valve has an in-
terlock device which will
not allow the pilot burner
to be lit until the ther-
mocouple has cooled.
Allow approximately 60
seconds for the thermo-
couple to cool.
System is not correctly
purged.
-
Purge the gas line.
Out of propane gas.
-
Fill the tank.
Pilot fl ame is not large
enough.
-
Turn up the pilot fl ame.
Pilot fl ame is not engulfi ng the
thermocouple
-
Gently twist the pilot head to improve the fl ame pattern
around the thermocouple.
Thermocouple shorting /
faulty.
-
Loosen and tighten thermocouple.
-
Clean thermocouple and valve connection.
-
Replace thermocouple.
-
Replace valve.
Faulty valve.
-
Replace.
Pilot burning; no gas to
main burner; gas knob is
on ‘HI’; wall switch / ther-
mostat is on.
Thermostat or switch is defec-
tive
-
Connect a jumper wire across the wall switch terminals;
if main burner lights, replace switch / thermostat.
Wall switch wiring is defective.
-
Disconnect the switch wires & connect a jumper wire
across terminals 1 & 3; if the main burner lights, check
the wires for defects and/or replace wires.
Main burner orifi ce is plugged.
-
Remove stoppage in orifi ce.
Faulty valve.
-
Replace.
PILOT
BURNER
THERMOCOUPLE
THERMOPILE