general information
1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in fl ame appearance from “HI” to “LO” is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and specifi cations
EX36
EX42
Fuel Type
Natural Gas
Propane
Natural Gas
Propane
Altitude (FT)
0-4,500
Max. Input (BTU/hr)
37,000
34,000
45,000
39,000
Min. Inlet Gas Supply Pressure
4.5” w.c. (11mb)
11” w.c. (27mb)
4.5” w.c. (11mb)
11” w.c. (27mb)
Max. Inlet Gas Supply Pressure
7”* w.c. (17mb)
13” w.c. (32mb)
7”* w.c. (17mb)
13” w.c. (32mb)
Manifold Pressure (Under Flow
Conditions)
3.5” w.c. (9mb)
10” w.c. (25mb)
3.5” w.c. (9mb)
10” w.c. (25mb)
Installer: please fi ll out appliance checklist
in the Owner’s manual.
*Maximum inlet pressure not to exceed 13”.
This appliance is suitable for use with Napoleon’s optional Dynamic Heat Control™ & Dynamic Heat Control™ Plus
systems. THIS MANUAL
DOES NOT
include detailed information relating to these optional systems. Framing and fi nishing
are
NOT
the same. For further details, refer to the Dynamic Heat Control™ installation manual provided with the kit before
starting installation.