5.0 remote exterior installation
Inside View
of Bulkhead
(Some Framing and
Finishing Hidden
for
Clarity)
GLASS GUARD
LVX 38 illustrated
Maintain
distance to
combustibles.
View of Opposite
Exterior Wall
Interior
Exterior
Appliance
Enclosure
Collar Plate
Assembly
6” Rigid Steel
Venting (not
supplied)
Air
Damper
Assembly
Blower
Housing
Assembly
Wall
Flashing
Decorative
Cover
Exterior Housing
Assembly
note:
MUST have air outlet opening.
note:
Diagram is for illustrative purposes only. Installation must comply with all local codes.
Appliance Vent
Terminal (if
applicable)
DHC™ Plus
remote exterior installation can be installed remotely from the appliance enclosure up to 60’ (18.2m)
away.
5.1
remote exterior installation overview
!
WARNING
• DHCP-BK
• DHCP-EK
Required:
• Venting, 6” rigid steel (not supplied)
• Minimum clearance to combustibles must be maintained or a serious fire hazard could result.
• DO NOT cover or place any items in the
Dynamic Heat Control™
air outlet opening. Failure to comply with
these instructions will create a fire hazard.
•
DHC™ Plus CANNOT be mounted directly above or below the appliance vent terminal as this will
cause the system to fail. It MUST be mounted to the left or right of the appliance vent terminal.
• For optimal performance, we recommend installing
DHC™ Plus
within the top 12” (30.5cm) of the enclosure.
However, it MUST be installed above the appliance.
• The minimum height requirement above the appliance will vary depending on the appliance size. See “minimum
venting requirements” section of your appliance manual for details.