36
W415-0899 / B / 03.13.12
COMBUSTIBLE
MATERIAL
SHELF
STEEL
HEADER
REQUIRED
IF USING
OPTIONAL
CLEAN
FACE
SURROUND
OR STYLO
GLASS
FACIA
(GD36M)
*6 1/2” MIN
NON-
COMBUSTIBLE
MATERIAL
2”
2”
1”
1 1/2”
2”
34”
49”
15”
0” IF NON-COMBUS
FINISHING IS USED
AS BRICK AND STO
43”
MINIMUM
PLUS RISE**
* If this appliance is installed
fl
ush to the
fi
nishing mate-
rial and optional clean face
surround or Stylo glass
facia is to be installed then
a minimum of 6 1/2" of
cement board or non-com-
bustible equivalent must be
used on the top only of the
front face.
** See Venting Section
NON-
COMBUSTIBLE
MATERIALS
ONLY
ALCOVE
AREA OVER
APPLIANCE
REAR
VENT
TOP
VENT
6.3.2 TOP VENT ENCLOSURE
6.3.3 ALCOVE ENCLOSURE
Alcoves above the appliance can be
made as deep as desired as long as
the clearances to combustibles are
maintained as in 6.3.1 and 6.3.2. If
clearances to vent components are
reduced, materials must be non-com-
bustible.