W415-0616 / C / 06.04.08
10
HEATER PLACEMENT
PLANNING YOUR INSTALLATION
Have an authorized dealer install the heater. If you install the heater yourself, have your dealer review your installation
plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in
this manual.
For built-in enclosures, when determining the location of the heater, locate the wall studs (for horizontal penetrations). You
may wish to adjust the heater position slightly to ensure the vent does not intersect with a framing member.
Heater must be positioned so that no combustibles are within, or can swing within (e.g. drapes, doors), 48" of the front of
the heater.
If the heater is placed in a location where the ceiling height is less than 7' above the base of the heater, the installation
must follow the requirements in the section "Alcove Installations Requirements"
Read this entire manual before you install and use this heater. failure to follow the instructions may result in
property damage, bodily injury, or even death.
Check with local building offi cials for any permits required for installation of this pellet heater and notify your insurance
company before proceeding with installation.
Before installing we recommend placing the heater outside and load 5 pounds of pellets inside the hopper. Plug the heater
in and let it run on HIGH until the pellets run out. This will cure the paint and burn off the oils on the steel, there by mini-
mizing any smell inside the home.
Electrical Rating
115 Volts, 3.6 Amps, 60Hz
Watts During Start-Up Sequence
400 (approximately)
Watts During Operation
180 (approximately)
NPS40 Width
22 3/8"
NPS40 Height
30 1/2"
NPS40 Depth
26 5/8"
Weight
210 Pounds
Exhaust Collar
3"
Intake Collar
2"
NPS40 Hopper Cap.
55 Pounds
NPI40 Hopper Cap.
45 Pounds
EPA
Exempt
Burn Rate**
1.0 to 5.0 (Pounds Per Hour)
BTU/h**
8500 to 42500
Minimum Fireplace Opening Size
Front: 22 1/2* W x 20 5/8 H x 14 1/4 D
Back: 20 3/8 W
This heater is EPA exempt from Phase II requirements, but
has been tested for emissions using EPA test methods by
Warnock Hersey.
SPECIFICATIONS
EPA COMPLIANCE
* In order to install fl ashing fl ush to fi nished wall and centered within the opening the front opening of the fi replace or
enclosure must be 32 5/8" wide.
!
WARNING
GENERAL INSTALLATION
Содержание Auburn NPS40
Страница 1: ...W415 0616 C 06 04 08 1 10 00 W415 0616 C 06 04 08...
Страница 4: ...W415 0616 C 06 04 08 4 WARNINGS AND SAFETY PRECAUTIONS...
Страница 5: ...W415 0616 C 06 04 08 5 WARNINGS AND SAFETY PRECAUTIONS...
Страница 7: ...W415 0616 C 06 04 08 7 DIMENSIONS Figures 1a b NPI40 with NI800 Flashing Shown NPS40 Figures 2a c...
Страница 33: ...W415 0616 C 06 04 08 33 Figure 49 NORMAL OPERATING SOUNDS...
Страница 34: ...W415 0616 C 06 04 08 34 WIRING DIAGRAM Figure 51...
Страница 36: ...W415 0616 C 06 04 08 36 COMMON REPLACEMENTS PARTS...
Страница 37: ...W415 0616 C 06 04 08 37 NPS40 REPLACEMENTS PARTS 57 38 61 44 63 65 57 64 56 58 59 60 66 15 31 39 54 40 53...
Страница 38: ...W415 0616 C 06 04 08 38 NPI40 REPLACEMENTS PARTS...
Страница 39: ...W415 0616 C 06 04 08 39 NPI40 ACCESSORY PARTS COMMON ACCESSORY PARTS...
Страница 44: ...W415 0616 C 06 04 08 44 NOTES...