background image

W415-0616 / C / 06.04.08

2

TABLE of CONTENTS

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

PG 3-5 

INTRODUCTION

  

Warranty

 

 

Warnings and safety precautions

6-10 GENERAL 

INTRODUCTION

  

General 

Instructions

  

Pellet 

Quality

  

Specifi 

cations   

 

 

  

Heating 

Specifi 

cations

  

Dimensions

  

Specifi 

cations

  

EPA 

Compliance

10-11 GENERAL 

INSTALLATION

 

 

Planning your Installation

  

Heater 

Placement

  

Installation 

Options

 

 

Floor Protection Requirements

  

Safety 

Features

  

Outside 

Air

  

Mobile 

Home

12-13 GENERAL 

VENTING

 

 

Type of Vent

   

 

Installing Pellet Vent

 

 

Venting the Pellet Heater

  

Pellet 

Vent 

Termination

 

 

Alcove Installation (NPS40 Only)

  

Minimum 

Air 

Terminal 

Installations

14-17 NPS40 

INSTALLATIONS

 

 

Minimum Clearance to Combustibles

  

Straight 

Installation

  

Corner 

Installation

 

 

Vertical Installation Examples

 

 

Horizontal Exhaust Through Wall Installation

 

 

Through wall with vertical rise and horizontal  

  

 

 

termination 

installation

 

 

Minimum Inside vertical clearance

 

 

Class A Chimney Retrofi t

 

 

Hearth Mount Installation

17-22 NPI40 

INSTALLATIONS

 

 

Minimum Clearance to Combustibles

 

 

Minimum Mantle Clearances

 

 

Rear or Top Vent Conversion Instructions

  

Installation 

Overview

 

 

Installation into a Masonry Fireplace

 

 

Prior to Installation

 

 

Installation into a masonry fi replace

 

 

Horizontal Vent Installation

 

 

Vertical Vent Installation

 

 

Installation into a Factory Built Fireplace

  

Framing 

(Built-in)

 

 

Prior to Installation

 

 

Installation into a masonry fi replace

  

Liner 

Installation

 

 

Installation into a combustible built in enclosure

 

 

Minimum framing dimensions

 

 

Minimum Enclosure Clearances

23  

NPI40 FINISHING

  

Flashing 

Installation

  

Trivet 

NPI40

 

 

Installing the viewing door NPS40 and NPI40

24   OPERATING 

INSTRUCTIONS

 

 Start 

up

  

Shut 

down

 

 

Lighting heater manually

 

 

Proper pellet loading

25-28 GENERAL 

MAINTENANCE 

NPS40 

  

AND 

NPI40

29   

NORMAL OPERATING SOUNDS

30  

WIRING DIAGRAM

31-35 REPLACEMENT 

PARTS

36-38 TROUBLE 

SHOOTING

39  

MAINTENANCE LOG

40  

NOTES 

Before installation, consult with the authority having jurisdiction (building department, fi re department etc...) to 
determine if there is the need to obtain a permit. 

NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.

Содержание Auburn NPS40

Страница 1: ...W415 0616 C 06 04 08 1 10 00 W415 0616 C 06 04 08...

Страница 2: ...stallation 17 22 NPI40 INSTALLATIONS Minimum Clearance to Combustibles Minimum Mantle Clearances Rear or Top Vent Conversion Instructions Installation Overview Installation into a Masonry Fireplace Pr...

Страница 3: ...warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructio...

Страница 4: ...W415 0616 C 06 04 08 4 WARNINGS AND SAFETY PRECAUTIONS...

Страница 5: ...W415 0616 C 06 04 08 5 WARNINGS AND SAFETY PRECAUTIONS...

Страница 6: ...STANDARDS If the fuel does not comply to this standard the unit may not operate as designed We recommend the use of premium grade 1 ash content for longer stove life and less frequent cleaning Fines n...

Страница 7: ...W415 0616 C 06 04 08 7 DIMENSIONS Figures 1a b NPI40 with NI800 Flashing Shown NPS40 Figures 2a c...

Страница 8: ...W415 0616 C 06 04 08 8 DIMENSIONS CONTINUED Figures 3a c NPI40 with AK9 Adapter and CISK Flashing Shown...

Страница 9: ...W415 0616 C 06 04 08 9 DIMENSIONS CONTINUED Figures 4a c NPI40 with AK8 Adapter and GICSK Flashing Shown...

Страница 10: ...injury or even death Check with local building of cials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation Before in...

Страница 11: ...ough the heater and shut down the pellet feed This lack of ow could be caused by a blocked vent POWER FAILURE In the event of a power failure the heater will shut down Once power is restored the heate...

Страница 12: ...ent manufacturer DO NOT CONNECT THE PELLET VENT TO A VENT OR CHIMNEY SERVING ANY OTHER APPLIANCE OR HEATER DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT INSTALLING THE PELLET...

Страница 13: ...ermination is located on a windy side of the house a shield is recommended to prevent soot from building up on the side of the house Horizontal terminations must protrude 12 from the wall vertical ter...

Страница 14: ...inside combustible corner wall or protruding combustible ob structions vent chase etc Clearance to a non mechanical air supply inlet to the building or a combustion air inlet to any other appliance C...

Страница 15: ...pellet vent is used the clearance to the back wall is determined by the upward turning elbow or Tee It will vary in depth depending on the brand of pellet vent used it is approximately 5 Before placi...

Страница 16: ...W415 0616 C 06 04 08 16 VENTING INSTALLATION EXAMPLES Figure 13 THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION Figure 14 HORIZONTAL EXHAUST THROUGH WALL INSTALLATION...

Страница 17: ...maintain 3 clearance to combus tibles Vertical Cap Roof Flashing Storm Collar Floor Protection 3 2 Class A Chimney Ceiling Support Outside air Recommended Installation showing inlet of out side air in...

Страница 18: ...ole sized for the pellet liner to lie directly below the replace ue opening Allow two inches of material for a ange on all sides and cut to these measurements Bend down the anges If you have never don...

Страница 19: ...NT CONVERSION INSTRUCTIONS NOTE The insert is factory shipped in a rear vent con guration 1 To vent exit vertically remove the two screws holding the exhaust cover NOTE Be careful not to damage the ga...

Страница 20: ...INIMUM MANTEL CLEARANCES Drywall or other combustible material See the sections GENERAL VENTING and INSTALLATION See the section MINIMUM FRAM ING DIMENSIONS Side Wall See the section MINIMUM CLEARANCE...

Страница 21: ...ommended to do so at this time 2 A hole must be made in the back of the replace to accommodate the pellet vent Connect the pellet vent to the back of the stove and position in place Refer to manufactu...

Страница 22: ...A non combustible hearth must cover the ooring underneath as well as extend a minimum of six in front and to both sides of the heater Install oor protection if necessary PRIOR TO INSTALLATION INSTALLA...

Страница 23: ...he insert into a built in combustible enclosure 1 Install oor protection 2 Frame structure maintaining minimum clearances Locate and frame openings for both the exhaust and outside air Outside air is...

Страница 24: ...the rear using the four 8 32 x 3 8 screws washers and nuts FIGURE 29 6 The three pieces of trim are assembled in the same manner as a picture frame Place the corner brackets with screw loosened into t...

Страница 25: ...the bag may come in contact with the heater causing the bag to melt and the pellets to spill DO NOT load pellets into the hopper if they have been exposed to moisture Moisture can cause pellets to sw...

Страница 26: ...RT switch 2 Rotate the Pellet feed dial rate to optimum 3 Adjust the air control rod to the preferred setting this position will vary depending on venting con guration and fuel quality 4 If the heater...

Страница 27: ...or well away from combustible materials pending nal disposal If ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders...

Страница 28: ...3 The burn pot requires cleaning 4 The exhaust system requires cleaning 5 The heater requires adjustment 6 Poor pellet quality MAKE SURE PELLETS ARE NOT PILING UP Figure 39 With the heater cool or wea...

Страница 29: ...ot Make certain that all openings are clear of any build up of ash from the ledge below the burn pot CLEANING THE BURN POT Re install the burn pot ensuring it sits level in the heater Also must ensure...

Страница 30: ...acuum out the entire hopper The dust and any other debris near the bottom should be removed to prevent excessive build up VACUUM HOPPER Figure 44 Cleaning the Optional Plated Surfaces Fingerprints or...

Страница 31: ...h exhaust port located on either side of the re box Remove the exhaust port doors and set aside on a non combustible surface SEMI ANNUALLY OR EVERY TWO TONS OF PELLET Figure 47 CLEAN THE EXHAUST BLOWE...

Страница 32: ...paper can be easily slid out air may be leaking around the door seal Carefully inspect the door gasket and door catch Inspect the door gasket to make sure it is fully attached Heater gasket cement can...

Страница 33: ...W415 0616 C 06 04 08 33 Figure 49 NORMAL OPERATING SOUNDS...

Страница 34: ...W415 0616 C 06 04 08 34 WIRING DIAGRAM Figure 51...

Страница 35: ...l parts can be or dered through your Authorized dealer or distributor When ordering replacement parts always give the following in formation 1 Model and Serial Number of the replace 2 Installation Dat...

Страница 36: ...W415 0616 C 06 04 08 36 COMMON REPLACEMENTS PARTS...

Страница 37: ...W415 0616 C 06 04 08 37 NPS40 REPLACEMENTS PARTS 57 38 61 44 63 65 57 64 56 58 59 60 66 15 31 39 54 40 53...

Страница 38: ...W415 0616 C 06 04 08 38 NPI40 REPLACEMENTS PARTS...

Страница 39: ...W415 0616 C 06 04 08 39 NPI40 ACCESSORY PARTS COMMON ACCESSORY PARTS...

Страница 40: ...run replace the blower If the motor runs have a dealer check the wire harness See The heater will not operate when hot section Contact your local dealer or a certi ed technician for service Push the...

Страница 41: ...lower controller replace the sensor If the motor is still on high re connect the sensor and replace the convection blower controller General Check the hopper for fuel Incorrect air damper setting may...

Страница 42: ...art replace the switch Due to different installation set ups length and size of venting and fuel quality the low feed setting from the factory will not always be correct It may be necessary to experim...

Страница 43: ...SERVICE AND MAINTENANCE LOG Dealer s Name Dealer s Address City State Province Zip Code Postal Code Serial Number Date of Purchase Date Installed Notes OWNERSHIP RECORDS SERVICE DATE SERVICE TECHNICI...

Страница 44: ...W415 0616 C 06 04 08 44 NOTES...

Отзывы: