A.
Remove the safety barrier and glass front, refer to "safety
barrier & door removal/installation" section.
B.
Remove the contents from the firebox and set aside, you will
need the exhaust flue collar from the top of the log carton.
C.
To ease assembly, remove the four hex head screws
securing the deflector from inside the top front of the firebox,
refer to Figure 1.
D.
Place the gasket (provided) over the 4" (102mm) flue collar
assembly and bend along perforation.
E.
From inside the firebox, insert the 4" (102mm) flue collar through the back
of the firebox. Install the rear exit shield onto the 4" (102mm) flue collar, see
"rear exit shield" section for installation instructions.
F.
Secure the flue collar assembly, gasket and rear exit shield using the four hex
head 3/8" thread cutting screws, refer to Figure 2.
G.
Reattach the deflector using the four screws and
install the log set, glass door and safety barrier.
H.
Install the 7" collar assembly, complete with
gasket, onto the rear panel around the 4"
(101.6mm) collar with the screws provided (FIG
3).
Fig. 2
DEFLECTOR
DÉFLECTEUR
Fig. 1
2.10 rear exit
• Failure to create a seal to the firebox with the exhaust collar assembly will cause the appliance to function
improperly and can cause injury or property damage.
!
WARNING
Do not overtighten. The gasket needs only to be
snug against the firebox.
note:
Fig. 3
INTAKE COLLAR
ASSEMBLY
GASKET
JOINT
D’ÉTANCHÉITÉ
COLLET
D’ÉVACUATION
2.11 rear exit shield (for rear vent only)
A.
Remove the safety barrier assembly and door from the appliance, refer to the “safety barrier & door
removal / installation” section of the manual for detailed instructions.
B.
Loosen the two screws, that secure the exhaust plate, and slide the shield in place by sliding its slotted
openings behind the screwheads,
tighten the two previously loosened
screws. Refer to the illustration .
C.
Reinstall the door and safety barrier
assembly on the appliance, see to
the “safety barrier & door
removal / installation” section.
This shield is used to block the view
through the venting to the outdoors.
note: