W415-2351 / B / 12.09.20
EN
26
rough framing
* See "VENTING" section.
REAR VENT
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 41 5/8" (1057mm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
For rear vent termination not exceeding 10" (254mm) of horizontal vent run.
NON-COMBUSTIBLE
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
24 3/16"
[61.4cm]
MINIMUM
PLUS RISE*
BRICK
COMBUSTIBLE
1"
[25mm]
3"
[76mm]
7"
[178mm]
41 5/8"
[105.7cm]
1"-10"
[25mm-254mm]
VENT RUN
34 5/8"
[87.9cm]
INCOMBUSTIBLE
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
BRIQUE
1"-10"
[25mm-254mm]
ÉVENTS
24 3/16"
[61,4cm]
MINIMUM
PLUS LA PENTE*
COMBUSTIBLE
1"
[25mm]
3"
[76mm]
7"
[178mm]
41 5/8"
[105,7cm]
34 5/8"
[87,9cm]
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
7"
[178mm]
41 5/8"
[105.7cm]
10"-20"
[254mm-508mm]
VENT RUN
11 1/2"
[292mm]
24 3/16”
[61.4cm]
MINIMUM
PLUS RISE*
34 5/8"
[87.9cm]
COMBUSTIBLE
1"
[25mm]
3"
[76mm]
7"
[178mm]
41 5/8"
[105,7cm]
10"-20"
[254mm-508mm]
ÉVENTS
11 1/2"
[292mm]
24 1/8”
[61,3cm]
MINIMUM
PLUS LA PENTE*
34 5/8"
[87,9cm]
INCOMBUSTIBLE
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
BRIQUE
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of combustible wall
penetration.