12
WI853C XP-400 Installation Instructions
lay, also program zones as
Exit/Entry Fol-
lower Zones [02].
To return protection to zones of this type,
press
#"
from the keypad or
or
from a Keyfob. Program the Keyfob AUX
1 or AUX 2 button for
Full Set [81-7].
[02]Exit/Entry Follower Zones
Entry Delay allows the user time to enter and
disarm. Allows exit after the panel is armed
without setting off an immediate alarm and
allows entry only if an
Exit/Entry Zone [00]
has been violated first. Zones of this type
have a three (3) minute power-up delay, and
do not display or cause an alarm if faulted
when the system powers up. Pressing the
"
key cancels the 3 minute timer.
Group Bypassing - Zones programmed as
Exit/Entry Follower Zones will be Group by-
passed if the
# #
is pressed while
disarmed or within the
Exit Delay.
Auto Interior Bypassing - Also program
zones as
Home/Away with Delay Zone(s) [01]
to automatically bypass at the expiration of the
exit delay if the
EXIT/ENTRY Zone(s) are not
violated during the exit delay.
[03]Auto-Bypass Reentry Zones
Zones programmed as this zone type are
permitted to be faulted at the time of arm-
ing. Once the zone is restored, while the
control panel is still armed, the zone will
automatically be unbypassed and any
subsequent violations of the zone will
cause an alarm condition.
[04]24-Hour Protection
A zone that provides protection at all times,
whether or not the system is armed.
[05]40 ms Loop Response
Normally loop response is 750 ms, select
this option to change the loop response to
40 ms. The slower the loop response, the
less sensitive the system will be to intermit-
tents (swingers). The programming option
is not permitted for UL installations.
[06]Open Circuit Zones
Program this zone type if unsupervised nor-
mally open circuit devices are required The
programming option is not permitted for UL
installations.
[07]Burg (Steady) Output
Enables the Bell Output on a zone trip for
each zone selected. The Bell Output will
remain ON for the length of time pro-
grammed for
Burg (Steady) Output [07] or it
will remain ON until turned off by entering a
valid Arm/Disarm Code; 0 means output will
stay ON until reset.
If
is
Entered during Exit Time, Home/
Away with Delay Zones will be automatically
bypassed, even if the Exit/Entry Zone is vio-
lated. Easy Exit/Easy Arm [22-2] must be en-
abled.
N
OTE
:
Normally Open Zone Wiring
Wire the normally
open contact
as shown (Zone 4).
EZ Zone Doubling
TM
resistor
is required.
Program the
zone for
Open Circuit [06].
(Z)
ZONE 1
(E)
.
ZONE 4
FIGURE
5 O
PEN
C
IRCUIT
W
IRIING
.
Wi853c
page 12