11
'HDOHU &RPPDQGV
Download (Programming Re-
quired)
Establish a connection between the PCD phone
line and the Control Panel phone line. When
ready, tell the installer to arm, then disarm. Then
enter
in order to establish a connection.
Phone connection to installer will go "dead" as
downloader and panel connect.
Fault Find ON/OFF
Hardwired Zone Operation
Enter this command to turn Fault Find ON/OFF.
While in Fault Find mode, the loop response for
all zones will be set to the faster response of 40
ms. The keypad will beep for .25-seconds when
hardwired zones are faulted and for 1-second
when zones are restored.
:LUHOHVV 2SHUDWLRQ
6LJQDO 6WUHQJWK
While in Fault Find mode the keypad will provide
an audible (Table 5) and visual (Figure 4) indica-
tion of each transmitter’s signal strength. The
signal strength metering is based on a scale of
4 to 10, with 4 being marginal and 10 being
excellent.
The keypad will beep out a number, from 1-4,
corresponding to the signal strength of the
transmitter. See Table 5 below. Each beep is
1-second long. The keypad will sound a short
beep for transmitters with signal strengths of 3
or less.
=RQH )HDWXUHV
[00]Exit/Entry Zones
Delay allows exit and entry through an Exit/
Entry Zone after the system is armed with-
out setting off an immediate alarm.
Exit
Delay allows the user to leave the premises
after arming.
Entry Delay allows the user
time to enter and disarm. The entry delay
may be canceled by pressing
!
.
[01]Home/Away with Delay Zones
Zones that automatically bypass at the expi-
ration of the exit delay if the EXIT/ENTRY
zone(s) are not violated. Zones of this type
have a three (3) minute power-up delay,
and do not display or cause an alarm if
faulted when the system powers up. Press-
ing the
"
key cancels the 3 minute timer.
If Exit/Entry zone(s) are violated during the
exit delay, zones programmed as Home/
Away with Delay Zone(s) will have a fixed
20-second entry delay, if violated before
the
Exit/Entry zone.
To eliminate this fixed 20-second entry de-
SIGNAL STRENGTH
KEYPAD SOUNDER
3 or less
.25
S BEEP
4
BEEP
5
BEEP BEEP
6-7
BEEP BEEP BEEP
8-10
BEEP BEEP BEEP BEEP
TABLE
5
A
UDIBLE
S
IGNAL
S
TRENGTH
I
NDICATION
FIGURE
4 V
ISUAL
S
IGNAL
S
TRENGTH
I
NDICATION
5
6-7
4
8-10
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
=21(
Wi853c
page 11
Tuesday, September 16, 1997 10:42