background image

NAPCO Gemini C

-

Series Control Panel Programming Instructions

--

Volume 2

 

NAPCO Security Group

 

Programming Instructions, Volume 2

 

Page 111

 

ALPHABETICAL INDEX (CONT'D)

 

Cold Start

 ........................................................................ 

37, 109

 

Combustion (Event ID Code)

................................................... 

32

 

Combustion Alarm (Modem Code)

 .......................................... 

62

 

Comm Bus 1 (Global Event/Trouble)

 ....................................... 

76

 

Configuration Mode (Burg)

 ...................................................... 

25

 

Configuration Mode (Fire)

 ....................................................... 

24

 

Continue Despite Mismatch

....................................................... 

7

 

CP

-

01 Test Signal

 ................................................................... 

97

 

CS Area & System Reporting Options (ADDRESS 1715

-

1718)61

 

CS Receiver Format Options (ADDRESS 0526)

 ..................... 

57

 

CS Receiver Format Options (ADDRESS 0551)

 ..................... 

57

 

CS Receiver Format Options (ADDRESS 0576)

 ..................... 

57

 

CS Receiver Format Options (ADDRESS 1038)

 ..................... 

57

 

CS Receiver Format Options (ADDRESS 1060)

 ..................... 

57

 

CS Receiver Format Options (ADDRESS 1082)

 ..................... 

57

 

CS Receiver Telephone Numbers (ADDRESS 1040

-

1059)

 .... 

58

 

CS Receiver Telephone Numbers (ADDRESS 1062

-

1081)

 .... 

58

 

CS Receiver Telephone Numbers (ADDRESS 1084

-

1103)

 .... 

58

 

CS Subscriber ID Numbers (ADDRESS 1150

-

1285)

 ............... 

59

 

CS System Report Options

 ..................................................... 

61

 

CS Telco 1 Subscriber Event ID Numbers

 .............................. 

59

 

CS Telco 2 Subscriber Event ID Numbers (Backup Reporting)

 

59

 

CS  Telco  2  Subscriber  Opening/Closing  ID  Numbers  (Backup 

Reporting)

 ............................................................................. 

59

 

CS Telco 3 Subscriber Event ID Numbers

 .............................. 

60

 

CS Telco 3 Subscriber Opening/Closing ID Numbers

 ............. 

60

 

CS Telco Options

 .................................................................... 

61

 

CS User Reporting Codes

--

Users 1

-

96 (ADDRESS 1725

-

1811)64

 

CS User Reporting Codes

--

Users 97

-

195 (ADDRESS 1737

-

1824)

 .............................................................................................. 

65

 

CS  Zone  Reporting  Codes

--

Zones  1

-

96  (ADDRESS  1440

-

1535)

 .............................................................................................. 

62

 

CS  Zone  Reporting  Codes

--

Zones  97

-

255  (ADDRESS  1536

-

1694)

 ..................................................................................... 

63

 

Customizing A Default Program

 .............................................. 

27

 

Day Zone/Trouble Open (Zone Option)

 ............................. 

79

91

 

Day Zone/Trouble Short (Zone Option)

 ............................. 

79

91

 

Dealer Code (Easy Menu)

 ....................................................... 

37

 

Dealer Keypad Program Code

 ................................................ 

15

 

Dealer Program Mode (exit)

 .................................................... 

37

 

Dealer Security Code

 .............................................................. 

56

 

default Burg User Code

 ........................................................... 

15

 

default Fire User Code

 ............................................................ 

15

 

default program

 ....................................................................... 

12

 

Delay Arming 1

-

4 hours (Burg Keypad Function Menu)

 .......... 

22

 

Delayed Trip 1 (Zone Option)

 ............................................ 

79

91

 

Delayed Trip 2 (Zone Option)

 ............................................ 

79

91

 

Dialing pause

 .......................................................................... 

31

 

Dial

-

Tone Detection

................................................................. 

31

 

Digital Dialer Test (Global Event/Trouble)

 ............................... 

76

 

Direct Address (Dealer Program) Mode (overview)

 ................. 

16

 

Direct Address Binary (Bit) Format Example

 ........................... 

51

 

Direct Address Decimal Format Example

 ................................ 

52

 

Direct Address Hexadecimal Format Example

 ........................ 

53

 

Direct Address Program Mode

 ................................................ 

51

 

Direct Address Program Mode (exiting)

 ................................... 

54

 

Disable 10 Minute Audible Auto Shutdown (ADDRESS 7953)

 

93

 

Disable a Zone / Output Circuit

 ............................................... 

13

 

Disable AC Fail Detection (ADDRESS 5325)

 .......................... 

93

 

Disable Answering

-

Machine Download (ADDRESS 5324)

 ...... 

92

 

Disable Area Entry Relays (ADDRESS 5327)

 ......................... 

93

 

Disable Auto

-

Reset In Day Zone/Trouble (ADDRESS 5324)

 ... 

92

 

Disable Auto

-

Unbypass On Disarming (ADDRESS 5322)

 ....... 

92

 

Disable Burg PGM1 Clear On Disarm (ADDRESS 5326)

 ........ 

93

 

Disable Call Waiting On First Attempt (ADDRESS 7953)

 ........ 

93

 

Disable Callback Download (ADDRESS 5324)

 ....................... 

92

 

Disable Closing Reports (ADDRESS 1716)

 ............................ 

61

 

Disable Code Required For EZ Bypass (ADDRESS 5325)

 ..... 

93

 

Disable Code Required For Func. Mode Lvl. 1 (ADDRESS 5325)

 .............................................................................................. 

93

 

Disable Exit/Entry Urgency Tone At Keypad (ADDRESS 5327)93

 

Disable H/A Keypad Display

 .................................................. 

101

 

Disable Keypad Function

-

Mode Download (ADDRESS 5324)

 . 

92

 

Disable Keypad Instant Button (ADDRESS 5325)

 ................... 

93

 

Disable Opening Reports (ADDRESS 1715)

 ........................... 

61

 

Disable Panel Error Check Required Mode

 ............................. 

93

 

DISABLE REMOTE REPORTING? (Fire Keypad Function Menu)

 .............................................................................................. 

20

 

Disable Wait For Handshake

 ................................................... 

61

 

Disable Zone Fault Scrolling (Auto Status) (ADDRESS 5326)

 . 

93

 

Disabled (Burglary User Option)

 .............................................. 

34

 

DISABLED Icon (function)

 ....................................................... 

13

 

Display Alarm Log (Burg Keypad Function Menu)

 ................... 

22

 

DISPLAY FIRE LOG (Fire Keypad Function Menu)

 ................. 

18

 

Display OP/CL Log (Burg Keypad Function Menu)

 .................. 

22

 

Display Phone Numbers? (Burg Keypad Function Menu)

 ........ 

21

 

DISPLAY RF XMITTER STAT (Fire Keypad Function Menu)

 .. 

19

 

Display RF XMITTER Stat? (Burg Keypad Function Menu)

 ..... 

22

 

Display System Log (Burg Keypad Function Menu)

 ................. 

22

 

Display System Troubles? (Burg Keypad Function Menu)

 ....... 

21

 

Display Total Log (Burg Keypad Function Menu)

 ..................... 

22

 

Display Zone Directory? (Burg Keypad Function Menu)

 .......... 

21

 

DO FIRE DRILL

 ....................................................................... 

13

 

DO FIRE DRILL (Fire Keypad Function Menu)

 ........................ 

18

 

DO ONE MAN TEST (Fire Keypad Function Menu)

 ................. 

18

 

Door Ajar Zone

 ........................................................................ 

99

 

Door Contact

 ........................................................................... 

99

 

Download Initiated Mismatch

 ..................................................... 

8

 

Download Security Code

 ................................................... 

15, 58

 

Download Security Code (ADDRESS 1144

-

1146)

 ................... 

58

 

download window

 .................................................................... 

10

 

Downloading From a Computer

 ............................................... 

16

 

Duct (Event ID Code)

 ............................................................... 

32

 

Duct Alarm (Modem Code)

 ...................................................... 

62

 

Easy Menu (exiting)

 ................................................................. 

37

 

Easy Menu Driven Program Mode

 ........................................... 

27

 

Easy Menu Programming Worksheets

 ............................... 

38

50

 

Easy Menu

-

Driven (Dealer Program) Mode (overview)

 ............ 

16

 

Easy Menu

-

Driven Program Mode (Chart Overview)

 ............... 

28

 

Easy  Programming  of  Auto  download  ID  #'s  and  PC  Preset 

Callback Numbers (Easy Menu)

 ............................................ 

32

 

Emergency Free Access (ADDRESS 7978)

 .......................... 

100

 

Enable 15 Ring Connection Method

 ........................................ 

92

 

ENABLE (CHANGE USER CODE) (Burg Keypad Function Menu)

 .............................................................................................. 

23

 

ENABLE (CHANGE USER CODE) (Fire Keypad Function Menu)

 .............................................................................................. 

19

 

Enable Access Logging Into Burg Log (ADDRESS 5890)

 ........ 

99

 

Enable ACM Access

 .............................................................. 

101

 

Enable All

-

Zone

-

In

-

Trouble Bypass (ADDRESS 5322)

 ............ 

92

 

Enable  Ambush  In  User  Assignment  Code  Type  (ADDRESS 

7953)

 ..................................................................................... 

93

 

Enable Burg Bell Chirp on Keyfob? (Easy Menu)

..................... 

31

 

Enable  Burg  Bell  On  Telco  Fail  Only  When  Armed  (ADDRESS 

5327)

 ..................................................................................... 

93

 

Enable Burg Module On System

 ............................................ 

101

 

Enable Burg Point Report Tamper Only If Zone Armed

 ......... 

101

 

Enable Burg. Bell Warning On Entry (ADDRESS 5323)

 .......... 

92

 

enable Burg

-

Only system

 ......................................................... 

12

 

Enable Cancel Report To Telco 3 (ADDRESS 7920)

 ............... 

93

 

Enable  Card  Presentation  Beep  and  Green  LED  Flash 

(ADDRESS 5890)

 .................................................................. 

99

 

Enable Co NACs Off On Fire Alarm

 ......................................... 

92

 

Enable Day Zone/Trouble Watch (ADDRESS 5321)

 ................ 

92

 

Enable Euro Features

 ............................................................ 

101

 

Enable Exit

-

Delay Restart (ADDRESS 5324)

 .......................... 

92

 

Enable Facility Code (ADDRESS 5890)

................................... 

99

 

Enable GEMC

-

F8ZCPIM

 ....................................................... 

101

 

Enable GEMC

-

Print (ADDRESS 7920)

 .................................... 

93

 

Enable Housing Tamper

 ........................................................ 

101

 

Содержание GEMINI C Series

Страница 1: ...ni C Series Control Panels with the GEMC FK1 Fire Keypad or the GEMC BK1 Burglary Keypad for Burglary Only systems WIRELESS HARDWIRE GEMC FK1 Keypad GEMC BK1 Keypad SYSTEM NORMAL 11 02 28 12 05 AM SYS...

Страница 2: ...the system must be monitored by a central station IMPORTANT NOTE The Gemini C Series combination Fire and Burglary control panels are normally programmed with the GEMC FK1 Fire keypad However the con...

Страница 3: ...Configuration Mode 24 GEMC BK1 Keypad Configuration Mode 25 Easy Menu Driven Program Mode 27 37 Easy Menu Programming Worksheets 38 50 Direct Address Program Mode 51 Address Mode Displays 51 Programmi...

Страница 4: ...displays when programming in Direct Entry Program Mode as follows A BINARY BIT FORMAT Settings such as Zone Features display and accept data in binary bit or number format For example Zone Features ar...

Страница 5: ...o the right upon each key press EXAMPLE Entries with the GEMC FK1 keypads Program Abort Delay to be 15 seconds DETERMINE THE DATA ENTRIES Referring to SYSTEM DELAYS TIMEOUTS in the Programming Workshe...

Страница 6: ...e in the programming worksheets that follow the Wireless Low Battery reporting code is located at address 7925 the data entries needed to assign a code of 1B are 1 and D1 PROGRAM THE DATA ENTRIES 1 En...

Страница 7: ...m or to make minor field alterations to an existing control panel program The panel MUST be uploaded to NAPCO s PCD Windows software following any keypad program ming the PCD Windows s error check fea...

Страница 8: ...e Press U to save SYSTEM RESPONSE ACTIVATED BY GLOBAL EVENT TROUBLE ADDR GLOBAL SYSTEM EVENT TROUBLE TELCO 1 FAIL TELCO 2 FAIL Telemetry Trouble Telemetry Failure GF RSRVD ACM Low Battery ACM Power Fa...

Страница 9: ...907 Defaults as noted from address 1900 1907 NOTE Keypad Aux is not to be selected for UL Installations SYSTEM RESPONSE ACTIVATED BY AREA 3 EVENT TROUBLE AREA 3 SYSTEM EVENT TROUBLE ADDR AMBUSH KEYPAD...

Страница 10: ...nk blank from address 1930 1937 NOTE Keypad Aux is not to be selected for UL Installations SYSTEM RESPONSE ACTIVATED BY AREA 6 EVENT TROUBLE ADDR AREA 6 SYSTEM EVENT TROUBLE AMBUSH KEYPAD PANIC KEYPAD...

Страница 11: ...Reserved 2085 Chime 2 2086 Delayed Trip 1 2087 Delayed Trip 2 2088 ZONE OPTIONS ADDR ZONES 1 8 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 1 2 3 4 5 6 7 8 Priority Zone 2002 Priority Bypass 2003 AutoBypass 2004 Selective...

Страница 12: ...Reserved 2185 Chime 2 2186 Delayed Trip 1 2187 Delayed Trip 2 2188 ZONE OPTIONS ADDR ZONES 9 16 Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 1 2 3 4 5 6 7 8 Priority Zone 2102 Priority Bypass 2103 AutoBypass 2104...

Страница 13: ...Reserved 2285 Chime 2 2286 Delayed Trip 1 2287 Delayed Trip 2 2288 ZONE OPTIONS ADDR ZONES 17 24 Z17 Z18 Z19 Z20 Z21 Z22 Z23 Z24 1 2 3 4 5 6 7 8 Priority Zone 2202 Priority Bypass 2203 AutoBypass 220...

Страница 14: ...Reserved 2385 Chime 2 2386 Delayed Trip 1 2387 Delayed Trip 2 2388 ZONE OPTIONS ADDR ZONES 25 32 Z25 Z26 Z27 Z28 Z29 Z30 Z31 Z32 1 2 3 4 5 6 7 8 Priority Zone 2302 Priority Bypass 2303 AutoBypass 230...

Страница 15: ...Reserved 2485 Chime 2 2486 Delayed Trip 1 2487 Delayed Trip 2 2488 ZONE OPTIONS ADDR ZONES 33 40 Z33 Z34 Z35 Z36 Z37 Z38 Z39 Z40 1 2 3 4 5 6 7 8 Priority Zone 2402 Priority Bypass 2403 AutoBypass 240...

Страница 16: ...Reserved 2585 Chime 2 2586 Delayed Trip 1 2587 Delayed Trip 2 2588 ZONE OPTIONS ADDR ZONES 41 48 Z41 Z42 Z43 Z44 Z45 Z46 Z47 Z48 1 2 3 4 5 6 7 8 Priority Zone 2502 Priority Bypass 2503 AutoBypass 250...

Страница 17: ...Reserved 2685 Chime 2 2686 Delayed Trip 1 2687 Delayed Trip 2 2688 ZONE OPTIONS ADDR ZONES 49 56 Z49 Z50 Z51 Z52 Z53 Z54 Z55 Z56 1 2 3 4 5 6 7 8 Priority Zone 2602 Priority Bypass 2603 AutoBypass 260...

Страница 18: ...Reserved 2785 Chime 2 2786 Delayed Trip 1 2787 Delayed Trip 2 2788 ZONE OPTIONS ADDR ZONES 57 64 Z57 Z58 Z59 Z60 Z61 Z62 Z63 Z64 1 2 3 4 5 6 7 8 Priority Zone 2702 Priority Bypass 2703 AutoBypass 270...

Страница 19: ...Reserved 2885 Chime 2 2886 Delayed Trip 1 2887 Delayed Trip 2 2888 ZONE OPTIONS ADDR ZONES 65 72 Z65 Z66 Z67 Z68 Z69 Z70 Z71 Z72 1 2 3 4 5 6 7 8 Priority Zone 2802 Priority Bypass 2803 AutoBypass 280...

Страница 20: ...Reserved 2985 Chime 2 2986 Delayed Trip 1 2987 Delayed Trip 2 2988 ZONE OPTIONS ADDR ZONES 73 80 Z73 Z74 Z75 Z76 Z77 Z78 Z79 Z80 1 2 3 4 5 6 7 8 Priority Zone 2902 Priority Bypass 2903 AutoBypass 290...

Страница 21: ...Reserved 3085 Chime 2 3086 Delayed Trip 1 3087 Delayed Trip 2 3088 ZONE OPTIONS ADDR ZONES 81 88 Z81 Z82 Z83 Z84 Z85 Z86 Z87 Z88 1 2 3 4 5 6 7 8 Priority Zone 3002 Priority Bypass 3003 AutoBypass 300...

Страница 22: ...NAC D 3183 Reserved 3184 Reserved 3185 Chime 2 3186 Delayed Trip 1 3187 Delayed Trip 2 3188 ZONE OPTIONS ADDR ZONES 89 96 Z89 Z90 Z91 Z92 Z93 Z94 Z95 Z96 1 2 3 4 5 6 7 8 Priority Zone 3102 Priority B...

Страница 23: ...umber of zones entered in AREA 1 ZONES 08 and AREA 2 ZONES 00 Alarm Telco 1 is enabled for the zones if YES is entered for REPORT ALL ZONES TO CENTRAL ZONES Y N Entry Exit 1 and Chime are enabled for...

Страница 24: ...shows option not available Press U to save 5321 System Options Enable Day Zone Trouble Watch Default Option OFF 1 RESERVED OFF 2 Enable Day Zone Trouble Watch Area 2 OFF 3 Enable Day Zone Trouble Watc...

Страница 25: ...Wireless Smoke Low Battery Resound OFF 2 Enable Cancel Report to Telco 3 OFF 3 Supervise Alarm Output on Burg Module OFF 3 Wireless Trouble to Telco 1 OFF 4 RESERVED OFF 4 Wireless Trouble to Telco 3...

Страница 26: ...ting the address of the receiver number Receiver 1 ad dress 7959 etc and entering the Type number right nibble data entry specified in the RECEIVER TYPE table at right Note All SLC RF receivers must b...

Страница 27: ...e Output On Fire SLC 2 7 Fire NAC Extender Note Only options 1 4 are available for Outputs 41 88 NUMBER OF RELAY BOARD MODULES ADDRESS 8060 Default blank blank ADDRESS 8060 LEFT RIGHT blank Number of...

Страница 28: ...O 3 8026 RESTORE REPORT TELCO 3 8027 Default blank from address 8024 8027 UNATTENDED DOWNLOAD MODE ADDRESS 8163 Unattended Download Mode When enabled allows unattended downloading from a computer for...

Страница 29: ...72 3 Press U to save NOTE Dark shaded data value box shows option not available for that Area Area 1 is a Fire Area only ADDR AREAS 1 8 EXIT ERROR A1 A2 A3 A4 A5 A6 A7 A8 1 2 3 4 5 6 7 8 EVENT REPORT...

Страница 30: ...Type Area Assignment Default blank blank ADDRESS 5364 LEFT RIGHT blank Keypad 15 Type Area Assignment KEYPAD TYPE AREA ASSIGNMENT Up to 15 keypads may be programmed if they are connected For Fire or...

Страница 31: ...Zone 5882 5887 Area for Door 2 5888 Reserved 5883 5889 Reserved 5884 5890 ACM Global Flags Default Option OFF 1 Enable Two Swipe Arming OFF 2 Enable NAPCO Proprietary Access Format OFF 3 Enable Facil...

Страница 32: ...r corresponding option number in address location NOTE Dark shaded data value box shows option not available Press U to save ACM SCHEDULED FREE ACCESS 1 Enter the Scheduled Free Access Index 1 88 outp...

Страница 33: ...exit entry door is faulted causing an entry time delay display or if a valid user code is entered at the keypad while the system is armed ADDRESS 5328 SYSTEM OPTIONS DATA ENTRIES RIGHT OPTION 1 Enabl...

Страница 34: ...6 38 5417 39 5418 40 5419 41 5420 42 5421 43 5422 44 5423 45 5424 46 5425 47 5426 48 5427 AREAS 1 8 USER NUMBER ADDR A1 A2 A3 A4 A5 A6 A7 A8 1 2 3 4 5 6 7 8 49 5428 50 5429 51 5430 52 5431 53 5432 54...

Страница 35: ...5521 143 5522 144 5523 AREAS 1 8 USER NUMBER ADDR A1 A2 A3 A4 A5 A6 A7 A8 1 2 3 4 5 6 7 8 145 5524 146 5525 147 5526 148 5527 149 5528 150 5529 151 5530 152 5531 153 5532 154 5533 155 5534 156 5535 15...

Страница 36: ...5606 EZM Group 27 ZONES 113 116 ADDRESS 5607 EZM Group 28 ZONES 117 120 ADDRESS 5608 EZM Group 29 ZONES 121 124 ADDRESS 5609 EZM Group 30 ZONES 125 128 ADDRESS 5610 EZM Group 31 ZONES 129 132 ADDRESS...

Страница 37: ...OUP NUMBER EZM PGM TERMINAL CONTROL ADDR A1 A2 A3 A4 A5 A6 A7 A8 1 2 3 4 5 6 7 8 1 5648 2 5649 3 5650 4 5651 5 5652 6 5653 7 5654 8 5655 9 5656 10 5657 11 5658 Default blank blank from address 5648 56...

Страница 38: ...Area 1 cannot be programmed for Priority Area Arming 1 Select the desired arming area 2 Enter the corresponding Area number in each the address location in Binary Bit Format NOTE See Direct Address Pr...

Страница 39: ...D TURNED OFF DISARMING AREA 2 TURNS OFF AREA OUTPUT ADDR A1 A2 A3 A4 A5 A6 A7 A8 1 2 3 4 5 6 7 8 Burglary Bell 5781 ON Pulsed Burg Bell 5789 ON Burg PGM2 5797 Burg Relay 5805 Burg PGM1 5813 Default No...

Страница 40: ...n 690 min 700 min 2550 min 42 Hr 30 min RF SUPERVISION TIMERS RF Supervision Timers may be programmed for each type of transmitter used A transmitter will send a transmission every time it is tripped...

Страница 41: ...Timer Auto Arm Disarm and Zone Descriptions Access address 8177 then press the U button Data entry is not allowed Note Enter Easy Menu Driven Program Mode to program system again GEMC FK1 Keypad 8177...

Страница 42: ...p 92 AutoBypass Zone Option 79 91 AutoBypass Re Entry Zone Option 79 91 Automatic Interior Bypass Easy Exit ADDRESS 5326 93 Auto Reset After Burg Bell Timeout ADDRESS 5323 92 AUX Options 36 Auxiliary...

Страница 43: ...93 Disable Callback Download ADDRESS 5324 92 Disable Closing Reports ADDRESS 1716 61 Disable Code Required For EZ Bypass ADDRESS 5325 93 Disable Code Required For Func Mode Lvl 1 ADDRESS 5325 93 Disab...

Страница 44: ...odem Code 62 Fire Monitor Batt Test Fail Modem Code 62 Fire Monitor EZM Tamper Alarm Modem Code 62 Fire Monitor Ground Fault Alarm Modem Code 62 Fire NAC Extender Output Type 95 Fire Output On 4 Wired...

Страница 45: ...etLink NL CSRCV Receiver format 32 Pull Station Event ID Code 32 Pull Station Alarm Modem Code 62 Pulse Burg Bell Zone Option 79 91 Pulse Burg Bell Timeout ADDRESS 5304 56 Quick Method Enroll Method E...

Страница 46: ...TEST COMMUNICATOR Fire Keypad Function Menu 18 Test Timer Global Event Trouble 76 testing the system 13 14 Total Number of Burg Zones in Area 2 Easy Menu 29 Total Number of Fire Zones in Area 1 Easy...

Страница 47: ...Closing Reports 61 1717 Telco Options and Timeouts 61 1725 1811 CS User Reporting Codes Users 1 96 64 1737 1824 CS User Reporting Codes Users 97 195 65 1850 1884 Global System Trouble Reporting Option...

Страница 48: ...On Disarm 93 5326 Disable Zone Fault Scrolling Auto Status 93 5327 Coded Cadence 4 Cycles only 93 5327 Disable Area Entry Relays 93 5327 Disable Exit Entry Urgency Tone At Keypad 93 5327 Enable Burg...

Страница 49: ...Simultaneous Silence 92 7952 Keypad 1 Always Unlocked for User Functions 92 7953 Disable 10 Minute Audible Auto Shutdown 93 7953 Disable Call Waiting On First Attempt 93 7953 Enable Ambush In User As...

Страница 50: ...NAPCO Security Group NAPCO Gemini C Series Control Panel Programming Instructions Volume 2 Page 118 Programming Instructions Volume 2 NOTES...

Страница 51: ...NAPCO Gemini C Series Control Panel Programming Instructions Volume 2 NAPCO Security Group Programming Instructions Volume 2 Page 119 NOTES...

Страница 52: ...ressly cancelled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products I...

Отзывы: