Programming Instructions, Volume 2
ACM DOOR AREA OPTIONS (ADDRESS 5894 -5901)
ACM SCHEDULED FREE ACCESS (ADDRESS 7970-7977)
ACM Door Number
ACM DOOR AREA OPTIONS
ADDR
Arm All
Areas
Allowed
Disarm All
Areas
Allowed
Stealth
Mode
RSRVD.
RSRVD.
RSRVD.
RSRVD.
RSRVD.
1
2
3
4
5
6
7
8
ACM 1
-
Door 1
5894
ACM 1
-
Door 2
5895
ACM 2
-
Door 1
5896
ACM 2
-
Door 2
5897
ACM 3
-
Door 1
5898
ACM 3
-
Door 2
5899
ACM 4
-
Door 1
5900
ACM 4
-
Door 2
5901
[Default = blank
(•)
blank
(•)
from address 5894
-
5901]
ACM DOOR AREA OPTIONS:
1.
Select the desired option entering the option number (1
-
3) for each address.
Note:
Area 1 available for Fire only.
2.
Enter corresponding option number in address location.
NOTE:
Dark shaded data value box shows option not available. Press
U
to save.
ACM SCHEDULED FREE ACCESS:
1.
Enter the Scheduled Free Access Index (1
-
88)
(output #1
-
88) for each option in the table at right.
Note:
Add 8 to the number of the external output to en-
sure the correct output is programmed.
2.
Press
U
to save.
Note:
Do NOT assign to Fire outputs.
Scheduled Free Access Index
ADDRESS
Output Number
(add 8 to external output
number)
ACM 1 –
Door 1 –
7970
ACM 1 –
Door 2 –
7971
ACM 2 –
Door 1 –
7972
ACM 2 –
Door 2 –
7973
ACM 3 –
Door 1 –
7974
ACM 3 –
Door 2 –
7975
ACM 4 –
Door 1 –
7976
ACM 4 –
Door 2 –
7977
[Default = blank
(•)
blank
(•)
from address 7970
-
7977]
EMERGENCY FREE ACCES S (ADDRESS 7978)
ENABLE ACM OPTION:
1.
Select the Emergency Free Access
Zone Number (1
-
255) and enter corre-
sponding address location at right.
2.
Press
U
to save.
ADDRESS 7978
Emergency
Free Access
Zone Number
[Default = 000]