4
Install strike plate
Place strike plate over
the F-TAB deadbolt
sensor. Align properly over
screw holes and punch
through the plastic
flange of the F-TAB
deadbolt sensor with an
awl or other sharp tool. Re-
place the 2 screws to secure
the strike plate. Ensure that
the F-TAB deadbolt sensor
hole is centered in the strike
plate opening.
15
Install F-TAB
deadbolt sensor
Using a wire snake, pull
wire from the deadbolt
strike hole and into the F-
LTRANS wire access
hole in wall. Place the F-
TAB sensor into deadbolt
hole. If the plastic F-TAB
sensor flanges protrude
past the area covered by
the strike plate, it may be
trimmed with a knife (see
image).
14
Drill Door Contact Hole
Drill a hole (B) for a 3/8” re-
cessed door contact sensor. To
maintain Door Kick-in Protection,
the sensor must be placed on the
"latch side" of the inside door frame
or the top of the door frame (header).
Install the door contact magnet into
the door. When the door is closed,
the magnet must be adjacent to the
sensor.
Warning:
When drilling
through door frame, always stay
clear of high voltage wiring which
may be present in the wall cavity.
12
B
Drill access hole for
F-TAB sensor
Drill a 3/8” hole in the deadbolt
hole (A) for a two conductor
wire to be run from the F-TAB
deadbolt sensor to the edge of
the door jamb. From this point,
the wire can emerge from the
wall and be placed next to the
door jamb or can continue
through the wall to the F-
LTRANS wireless transmitter,
as necessary.
11
A
Locate the F-LTRANS
wireless transmitter
:
Mount the F-LTRANS inside a
drop ceiling, above the door
frame, or in any location suitable
for the installation (see illustration
for possible locations). Using its
mounting base as a template,
mark the mounting holes and wire
access hole (leaving at least ¾"
from the edge of the door molding
to allow for the greater width of the
F-LTRANS case). Drill the wire
access hole as necessary.
10
Possible
mounting
locations
Install Recessed Door
Contact
The door contact sensor wires
must be connected to the F-
LTRANS wireless transmitter.
Insert wire snake into the F-
LTRANS wire access hole and
out through the door contact
sensor hole in the door frame.
Connect the end of the sensor
wires to the wire snake and pull
wires into door frame and out
the F-LTRANS wire access hole
in wall.
13
Place "tab" closer to the
inside (protected) side of
the premises.
Flange (cut to size)
Install the F-LTRANS
(
Note:
Do NOT install battery until
wiring is complete). Mount the Transmit-
ter base (screws provided) with all wires
from the wall hidden under the Transmit-
ter. Wire the F-LTRANS as follows:
•
Twist together one wire from the F-TAB
deadbolt sensor and one from the door
contact and screw into center terminal.
•
Insert remaining F-TAB deadbolt sen-
sor wire into left terminal and secure.
•
Insert the remaining door contact wire
into the right terminal and secure.
Do NOT install the Transmitter cover.
16
Rotary Wood
Rasp
To increase the
depth
of the dead-
bolt hole,
use a 1" spade bit
(shown).
Remove the remaining wood
from the
deadbolt hole opening using a rotary wood
rasp. The opening must not obstruct the
installed F-TAB deadbolt sensor or the
closed deadbolt.
9
1"
Flange
(cut to
size)
BATT.
BOLT
COM
DOOR
F-TAB
SENSOR
N/C DOOR
SENSOR