Test fit the F-TAB sensor
into the deadbolt strike hole.
For increased kick-in protec-
tion, place the sensor "tab"
closer to the inside
(protected) side of the prem-
ises. Determine if the dead-
bolt hole will need enlarging.
The F-TAB sensor requires a
depth of approximately 1". In
addition, one side of the
deadbolt hole must be enlarged to
accommodate the sensor "tab".
Remove the strike plate
Screws
Remove the two screws
securing the deadbolt
strike plate to the door
frame. If there is a dust cup
installed, it must be re-
moved.
6
Strike Plate
Door Frame
Molding
Screws
Installing the NAPCO F-TP Touchpad, F-TAB Deadbolt Sensor and the F-LTRANS wireless transmitter
Cut access hole
Install (4) wall anchors and cut
access hole in wall. Pull 4 con-
ductor bus wire from F-8 Panel into
opening. If necessary, remove a small
amount of insulation in the hole. Be
sure that the hole is located to allow
the antenna wire to be positioned
straight down as shown.
Warning:
Use caution when cutting
holes. There may be high voltage
wiring in the wall. Wood beams may
obstruct the antenna installation.
Chose the location carefully.
3
Mark the holes
.
The F-TP Touchpad can be mounted
anywhere, provided its PIR directly
supervises the deadbolt latch on the pro-
tected door.
Note:
Select a location that
will allow the antenna to be positioned
straight down as shown in Step 3.
Place the template against the selected
wall at a height of approx. 60" (to the top of
the Touchpad).
Mark or punch through the 4 oval mounting
holes and the wire access opening.
2
60”
Ç
TOP UP
Open the F-TP
Touchpad
.
Remove
the front of the
Touchpad housing by in-
serting a screwdriver into
the (2) slots in the bottom
of pad. Twist screwdriver
to remove cover.
1
TOP UP
Future Location
of antenna wire
(to be kept
straight)
Make Connections and
Create Service Loop
Punch holes with an awl in
the F-TP Touchpad base fitting
the wire sizes used. Pull wires
through base. Secure base to
wall. Wire to F-TP Touchpad
using wiring diagram as a guide.
Push all excess wire back into
wall leaving a short loop (about
3”-4”) of slack wires for service
purposes. Test fit the cover, but
do not secure.
4
MOUNT AND WIRE THE F-TP TOUCHPAD
MOUNT AND WIRE THE F-TAB SENSOR AND WIRE THE DOOR SENSOR TO THE F-LTRANS
7
Place "tab" closer to the
inside (protected) side of the
premises. The "tab" side of
the deadbolt hole must be
enlarged if necessary.
Enlarge the deadbolt hole
us-
ing the supplied drilling guide.
Secure the drilling guide to the bolt
hole using the strike plate screws.
With a ¼" bit, hold the drill level and
drill through the (2) holes of the guide
matching the location of the sensor
"tab" to a depth of approximately
1½".
Remove the
drill guide
when done.
8
The template is used as a
guide for enlarging the
existing deadbolt hole.
Use only an F-TAB deadbolt sensor as shown be-
low.
5
F-TAB deadbolt sensor
Содержание F-TP Touchpad