F-TP TOUCHPAD PIR 

 
The F-TP TOUCHPAD includes an integral PIR sensor which 
provides the following system functions: 
 

Activity Sensor 

The PIR is always gathering activity information which provides 
the system with data that is used to insure proper use of the sys-
tem and prevent user errors.  For example, if the user presses 
the AWAY button, opens and closes the door and locks the dead-
bolt but does not leave, the PIR will sense the user’s presence in 
the home and automatically default to STAY mode arming, pre-
venting a false alarm.  If additional PIR sensors are installed, the 
activity of these sensors will also be included in these decision 
making processes.     
 

Intrusion Protection Device 

When the system is armed AWAY, the PIR provides intrusion 
protection with a range of 25’ at a 90° pattern of protection.  An 
intruder detected in this protected area will cause a Zone 2 alarm 
(or Zone 8 alarm for TP #2) with a corresponding central station 
report and audible alarm.  

NOTE: 

 If Touchpad PIR Intrusion Pro-

tection is not desired, it may be disabled by installing configura-
tion jumper JP1.2. 
 

Anti-Tamper Protection 

The Touchpad PIR also includes 2 side beams which provide 
tamper protection for the deadbolt.  These side beams provide a 
170° pattern of protection, which is intended to prevent an in-
truder from walking along the wall towards the Touchpad and 
deadbolt.  If an intruder is detected in the Anti-Tamper zone, the 
system will be put into a lockout state for a period of several min-
utes, during which the system may only be disarmed with an F-
IFOB.  In cases where an extremely large signal is generated in 
the Anti-Tamper zone, an actual Zone 2 alarm (or zone 8 alarm 
for TP #2) may occur.   
 
If a Secondary transmitter is installed (used only to monitor an-
other deadbolt on exit and for entry), care must be taken to en-
sure an intruder can not disarm the system by turning the dead-
bolt latch at this Secondary transmitter.  See 

INSTALLING A 

SECOND F-LTRANS

 on page 2 for more information. 

 

NOTE:

  If there are windows on the wall on which the Touchpad 

is mounted, they should remain closed while system is armed in 
order to prevent a draft from causing an Anti-Tamper condition.  
 

If the deadbolt can be accessed from an area that is not cov-
ered by the pattern of protection provided by the Touchpad 
PIR, then additional protection is required.  This may include 
protecting other doors and windows or additional space pro-
tection.  

If the Touchpad is installed adjacent to a door with glass 
panels or side lights, a glass-break sensor (connected to the 
F-TP Touchpad Aux. Zone) should be installed to insure the 
integrity of the system.

 

 
 

5’ 

25’ 

5’ 

10’ 

15’ 

20’ 

Side View 

25’ 

90º 

5º 

Anti-Tamper Beams

 

Intrusion Protection 
Beams

 

Top 

View 

Содержание F-TP Touchpad

Страница 1: ...aged a high security feature normally found only in very elaborate high end installations INTEGRAL WIRELESS RECEIVER The F TP Touchpad incorporates an integral RF receiver This receiver receives transmissions ONLY from the F LTRANS wireless transmitter no other transmitters will work with this re ceiver The system uses two different frequencies to reduce nulls and prevent noise on a single frequen...

Страница 2: ...itter The Secondary transmitter should always be tested prior to installation as follows After installing and learning the Primary transmitter place the Secondary transmitter in the selected mounting location and remove the cover Remove the F TP Touchpad from its backplate and have someone observe the re ceiver LED as the Secondary transmitter tamper switch is pressed and released The receiver LED...

Страница 3: ...ned straight down as shown in Step 3 Place the template against the selected wall at a height of approx 60 to the top of the Touchpad Mark or punch through the 4 oval mounting holes and the wire access opening 2 60 Ç TOP UP Open the F TP Touchpad Remove the front of the Touchpad housing by in serting a screwdriver into the 2 slots in the bottom of pad Twist screwdriver to remove cover 1 TOP UP Fut...

Страница 4: ... Mount the F LTRANS inside a drop ceiling above the door frame or in any location suitable for the installation see illustration for possible locations Using its mounting base as a template mark the mounting holes and wire access hole leaving at least from the edge of the door molding to allow for the greater width of the F LTRANS case Drill the wire access hole as necessary 10 Possible mounting l...

Страница 5: ...TAY lights on the Touchpad should turn on the system armed STAY 4 Disengage the deadbolt and the system should disarm and turn back off READY light turns on 5 Open the door The Touchpad should sound a chime If there is a problem see Troubleshooting on page 9 To learn a second transmitter start again at step 17 21 Multiple Transmitters Notes The Primary transmitter that is lo cated in the same room...

Страница 6: ...shown on wiring dia gram Terminal 1 is 12 V DC Term 2 is GND and Term 3 is Data Terminal 4 Alarm Output Terminal 4 is wired to terminal 14 Bell of the F 8 Panel to drive the internal alarm sounder of the F TP Touchpad upon alarm Terminal 8 9 Zone 2 Aux Zone Terminals 8 9 are the connections for the Aux Zone This zone may be wired to a motion sensor glass break sensor or a magnetic contact Cut jump...

Страница 7: ...on which is intended to prevent an in truder from walking along the wall towards the Touchpad and deadbolt If an intruder is detected in the Anti Tamper zone the system will be put into a lockout state for a period of several min utes during which the system may only be disarmed with an F IFOB In cases where an extremely large signal is generated in the Anti Tamper zone an actual Zone 2 alarm or z...

Страница 8: ...FIRE BELL GND GREEN BLACK RED 2 WIRE SMOKE DETECTORS RED BLACK GREEN YELLOW FREEDOM F 8 CONTROL PANEL See WI1076 for more information YELLOW 2 2K 2 2K ZONE 3 ZONE 4 F PROG OPTIONAL GEM RECV XP8 OPTIONAL 2 2K 2 2K ZONE 5 ZONE 6 RED BLACK GREEN YELLOW JP1 ADDR PIR AUX2 1 2 3 4 ZONE 8 PIR GLASS BREAK SEN SOR ETC COM F TP 2 Optional 8 9 Location of Wireless Receiver Circuit Board Location of Wireless ...

Страница 9: ...tter is intentionally learned clear the F TP Touchpad memory and re learn the transmitter as follows Using a pen tip press and hold the F TP Touchpad receiver button down about 6 seconds until the LED turns on steady Release the button and the LED will flash rapidly indicating the receiver is in Learn Mode with all pre existing data erased 4 Note Transmitters CANNOT be programmed with their covers...

Страница 10: ...10 NOTES ...

Страница 11: ...11 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 12: ... 2 3 8 4 3 8 3 5 16 Wire Access Hole Cut in Wall SINGLE GANG MOUNTING HOLES It may be necessary to drill a hole in the single gang box to allow the antenna wire to be positioned straight down as shown in the previous installation instructions ...

Отзывы: