7
F-TP TOUCHPAD PIR
The F-TP TOUCHPAD includes an integral PIR sensor which
provides the following system functions:
Activity Sensor
The PIR is always gathering activity information which provides
the system with data that is used to insure proper use of the sys-
tem and prevent user errors. For example, if the user presses
the AWAY button, opens and closes the door and locks the dead-
bolt but does not leave, the PIR will sense the user’s presence in
the home and automatically default to STAY mode arming, pre-
venting a false alarm. If additional PIR sensors are installed, the
activity of these sensors will also be included in these decision
making processes.
Intrusion Protection Device
When the system is armed AWAY, the PIR provides intrusion
protection with a range of 25’ at a 90° pattern of protection. An
intruder detected in this protected area will cause a Zone 2 alarm
(or Zone 8 alarm for TP #2) with a corresponding central station
report and audible alarm.
NOTE:
If Touchpad PIR Intrusion Pro-
tection is not desired, it may be disabled by installing configura-
tion jumper JP1.2.
Anti-Tamper Protection
The Touchpad PIR also includes 2 side beams which provide
tamper protection for the deadbolt. These side beams provide a
170° pattern of protection, which is intended to prevent an in-
truder from walking along the wall towards the Touchpad and
deadbolt. If an intruder is detected in the Anti-Tamper zone, the
system will be put into a lockout state for a period of several min-
utes, during which the system may only be disarmed with an F-
IFOB. In cases where an extremely large signal is generated in
the Anti-Tamper zone, an actual Zone 2 alarm (or zone 8 alarm
for TP #2) may occur.
If a Secondary transmitter is installed (used only to monitor an-
other deadbolt on exit and for entry), care must be taken to en-
sure an intruder can not disarm the system by turning the dead-
bolt latch at this Secondary transmitter. See
INSTALLING A
SECOND F-LTRANS
on page 2 for more information.
NOTE:
If there are windows on the wall on which the Touchpad
is mounted, they should remain closed while system is armed in
order to prevent a draft from causing an Anti-Tamper condition.
•
If the deadbolt can be accessed from an area that is not cov-
ered by the pattern of protection provided by the Touchpad
PIR, then additional protection is required. This may include
protecting other doors and windows or additional space pro-
tection.
•
If the Touchpad is installed adjacent to a door with glass
panels or side lights, a glass-break sensor (connected to the
F-TP Touchpad Aux. Zone) should be installed to insure the
integrity of the system.
5’
25’
5’
10’
15’
20’
Side View
25’
90º
5º
Anti-Tamper Beams
Intrusion Protection
Beams
Top
View