Technisches
Handbuch
SMCI12
Connection and commissioning
2.3 Commissioning
Introduction
The connection and commissioning of the SMCI12 stepper motor are described
below.
This section describes the main first steps you need to take to be able to quickly begin
working with the SMCI12 if you are using the NanoPro (SMCI12) or NanoCAN
(SMCI12-3) software from a PC. You will find more detailed information in the
separate NanoPro and NanoCAN manuals.
If you want to work with a PLC or your own program later, you will find the necessary
information in the separate programming manual.
Familiarize yourself with the SMCI12 stepper motor control and the corresponding
NanoPro or NanoCAN control software before you configure the controller for your
application.
Commissioning with NanoPro (SMCI12 with RS485 firmware)
Proceed as follows to commission the controller with the RS485 firmware:
Step Action
Note
1
Install the NanoPro control software on your PC.
See the NanoPro separate manual.
Download of
www.nanotec.com
2
Connect the controller to the stepper motor
according to the connection diagram.
Connection diagram, see
Section 2.2.
Detailed information on
connections can be found
in Chapter 3.
3
Switch on the operating voltage
(12-24 V DC).
4
If necessary, install the driver for the converter
cable ZK-RS485-USB.
Download
www.nanotec.com
in the
Accessories/Converter
menu item
5
Connect the controller to the USB port of your
PC.
Use the converter cable
ZK-RS485 and the cable set ZK-SMCI12.
Order identifier:
•
ZK-RS485-USB
•
ZK-SMCI12
6
Start the NanoPro software.
The NanoPro main menu
appears.
7
Select the <Communication> tab.
Issue: V 1.0
9