5 General concepts
Not ready to
switch on
Start
Software cannot
rectify error
Switched on
disabled
Ready to
switch on
Switched on
Operation
enabled
Quick stop
active
Fault
Fault reaction
active
Error occures
Torque
voltage switched on for controller
High-level voltage switched on
High-level power
voltage switched on for controller
High-level voltage switched on
No torque at motor
Low-level power
voltage switched on for controller
High-level voltage can be switched on
605D
h
Halt
605E
h
605A
h
605C
h
605B
h
Disable
voltage
Transition with
break reaction
Transition without
break reaction
Index of the object that
specifies the reaction
5.2.2.2 Quick stop active
Transition to the Quick stop active state (quick stop option):
In this case, the action stored in object 605A
h
is executed (see following table).
Value in object 605A
h
Description
-32768 … -1
Reserved
0
Immediate stop
1
Braking with slow down ramp (braking deceleration depending on
operating mode) and subsequent state change to Switch on disabled
2
Braking with quick stop ramp and subsequent state change to
Switch on disabled
3 … 32767
Reserved
Version: 2.0.1 / FIR-v1650