![NANOTEC PD4-C Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514129.webp)
9 Description of the object dictionary
Object description
Index
2035
h
Object name
Lower Voltage Warning Level
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
00002710
h
Firmware version
FIR-v1426
Change history
Description
If the input voltage of the controller falls below this threshold value, the motor is switched off and an error
triggered. The error is reset automatically if the input voltage exceeds the voltage of object 2035
h
plus 1.5
volts.
2036h Open Loop Current Reduction Idle Time
Function
This object describes the time in milliseconds that the motor must be at a standstill before current reduction
is activated.
Object description
Index
2036
h
Object name
Open Loop Current Reduction Idle Time
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
000003E8
h
Firmware version
FIR-v1426
Change history
2037h Open Loop Current Reduction Value/factor
Function
This object describes the rms current to which the motor current is to be reduced if current reduction is
activated in open loop (bit 3 in 3202
= "1") and the motor is at a standstill.
Version: 2.0.1 / FIR-v1650
129