9 Description of the object dictionary
Description
If this range is exceeded or not reached, an overflow occurs. To prevent this overflow, limit values for the
target position can be set in object 607D
("Software Position Limit").
607Ch Home Offset
Function
Specifies the difference between the zero position of the controller and the reference point of the machine in
user-defined units.
Object description
Index
607C
h
Object name
Home Offset
Object Code
VARIABLE
Data type
INTEGER32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
607Dh Software Position Limit
Function
Defines the limit positions relative to the reference point of the application in user-defined units.
Object description
Index
607D
h
Object name
Software Position Limit
Object Code
ARRAY
Data type
INTEGER32
Savable
yes, category: application
Firmware version
FIR-v1426
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Version: 2.0.1 / FIR-v1650