Chapter 2. Preparation and Installation
HR8 Motor User Manual
2-6
4. Referring to the figure below, apply two drops of epoxy
adhesive, on the center of the Ceramic driving plate
upper
surface, about 2cm apart. The Epoxy must bond between the
plate and the stage.
Recommended adhesive:
!
Emerson & Cuming ecobond 24, for vacuum applications
!
3M 2216 epoxy or CIBA GEIGEY Arldite Radite, for
non-vacuum applications
NOTE:
Be sure the epoxy contacts the upper surfaces of the plate
and the stage carriage but
does not flow over
the Ceramic plate
front surface.
2 cm
Ceramic Plate
Epoxy
Stage
Figure 2-4: Securing the Ceramic Driving Plate to the Stage
5. Allow the required time period for curing, according to the
Epoxy manufacturer specifications.
6. Mount the motor according to the following section.