18
Zetasinter System
®
-
Install the four refractory blocks (Ø85x90mm) and the alumina plate (100x75mm
→
possibility of
using 2)
-
Two refractory blocks must be placed almost in contact with the crucible as shown in the figure
below. It is recommended to use marks on the crucible hook at 36, 45 and 55 cm.
-
If
the refractory blocks are not positioned correctly, this can lead to tube failure.
Maintenance
After every heat treatment:
-
Clean the binder residues in the outlet flange with a degreaser. Use a
bottle brush to clean the outlet valve. Please note that only
refractory blocks are required to debind/sinter Zetamix ceramics. No
need to put and close the flanges.