background image

 Exhaust gas

Exhaust gases contain carbon monoxide. This colour-

less and odourless gas is extremely harmful and could 

lead to poisoning which could result in loss of conscious-

ness or death. The first symptoms of carbon monoxide 

intoxication are as follows:

Dizziness

Nausea

Headache

Throbbing temples

Vomiting

Fatigue and falling asleep

Tense muscles

If you or anyone else in the vicinity of the generating set 

experiences any of these symptoms, leave the area of 

operation of the generating set and find fresh air. If the 

symptoms persist, consult a doctor and have your gen-

erating set checked.

 Risk of electric shock

Never touch the electrical connectors when the gener-

ating  set  is  operational. The  voltage  at  the  connector 

terminals can be lethal.
Do not work on the generating set without protection: 

protective goggles and gloves, insulating blankets etc.
Always disconnect the generating set and cut the cur-

rent before working on the electrical system. Isolate the 

shore  power  supply  to  all  the  electrical  circuit  equip-

ment.
Ensure  your  clothing  and  skin  is  not  damp  or  sweaty 

when  handling  electrical  equipment.  Remove  watch-

es, bracelets and jewellery when working on electrical 

equipment.
Handling a capacitor that is still charged can be danger-

ous and cause electrocution. 

 Risk of burns

Never touch the hot parts of the generating set or the 

exhaust circuit. 
An operational generating set gets very hot: the exhaust 

elbow and pipe, turbocompressor, starter, oil sump, oil, 

coolant in the hoses and pipes are hot and can burn. 
Always check the coolant level before starting the gen-

erating set.
Fluids ejected under pressure can cause serious injury. 
Release all the pressure in the circuits before removing 

the caps. 
Never open the coolant and oil circuit caps when the 

generating set is operational and/or hot. 
Never start or run the generating set when the oil fill cap 

is not screwed on as hot oil could spray out. 

If you come into contact with any of these fluids, consult 

a doctor immediately. 
If the generating set gets too hot, switch it off and dis-

connect it and wait for it to cool down before handling.

 Risk of fire

Do not smoke near the generating set and keep it away 

from sources of ignition (flames or sparks) or any other 

potential flammable vapour or liquid sources. 
Do not run the generating set without an air filter. 
Do not run the generating set in an area in which flam-

mable or explosive materials are stored or where gas is 

present. Ensure there are no flammable liquids in the 

engine compartment.
Immediately clean up any liquids spilled over yourself or 

the floor and keep the engine compartment clean and 

accessible so as to minimise the risk of fire. Be careful 

as fuel can burn.

 Risk of explosion

Explosions  caused  by  fuel  vapour  can  cause  serious 

injury! Carefully follow the safety rules when filling the 

fuel. 
Open and ventilate the storage area of the generating 

set after filling. Check that there are no fuel vapours or 

leaks before starting the fan (if fitted). Switch the fan on 

for 5 minutes before starting the generating set.
All fuel vapours are flammable and explosive. Be care-

ful when handling and storing fuel. Store the fuel in a 

ventilated area away from sources of ignition (sparks or 

flames) and out of the reach of children.
Stop the generating set before filling with fuel or lubri-

cant. Do not smoke near the generating set and keep it 

away from sources of ignition (flames) when filling with 

fuel  and/or  lubricant.  Wear  gloves  when  investigating 

possible leaks. 
Do not alter or damage the fuel circuit. Close the fuel 

circuit whenever you work on it.
Ensure you always have an appropriate working extin-

guisher to hand.

Safety precautions 

5

Содержание QLS 10T

Страница 1: ...MARINE GENERATING SET INSTRUCTION MANUAL MU_GE_970315535_ENG QMS 32T QMS 39T QLS 32T QLS 39T QLS 47T...

Страница 2: ......

Страница 3: ...l system 16 Bleeding the fuel circuit 16 Replacing the fuel filter 16 Replacing the fuel prefilter 16 Draining the water from the fuel prefilter 16 Lubrication system 17 Checking the oil level 17 Drai...

Страница 4: ...should be carried out by Nanni Diesel authorised per sonnel or by a professional If you have to work on the generating set carefully follow the safety instructions set down in this manual Certain info...

Страница 5: ...ant and oil circuit caps when the generating set is operational and or hot Never start or run the generating set when the oil fill cap is not screwed on as hot oil could spray out If you come into con...

Страница 6: ...nal I Rotating parts Rotating parts can be extremely dangerous and cause serious injury and even death Do not work on the generating set when it is operational If work on the engine when running is ab...

Страница 7: ...use special filters Avoid using fuel mixed with water or other substances as you may damage the engine The engine performance is influenced by the fuel tem perature the temperature and relative humidi...

Страница 8: ...ng I Caution Your generating set must be installed by a shipyard or authorised representative following the on board assembly instructions The electrical connections must also be carried out by qualif...

Страница 9: ...gauge 14 Fuel filter 15 Fuel pump 16 Supports 17 Generator 18 Generator identification plate 19 Engine identification plate 20 Generating set hoisting eyes Principal parts of the generating set QLS32T...

Страница 10: ...orifice 11 Oil filter 12 Oil drain pump option 13 Oil gauge 14 Fuel filter 15 Fuel pump 16 Supports 17 Generator 18 Generator identification plate 19 Engine identification plate 20 Generating set hoi...

Страница 11: ...3 Battery charge This indicator illuminates when the set is switched on If it lights when the generating set is running this indicates an engine alternator charging fault 4 Oil pressure This indicator...

Страница 12: ...INJECTION SYSTEM QMS32T QLS32T QMS39T QLS39T QLS47T Combustion principle Indirect Direct Intake Atmosph rique Natural Turbo Injectors Type Bosch mini Injection pressure bar 140 250 Fuel type Gazole NF...

Страница 13: ...circuit compo nent has been replaced Starting the generating set I Caution On a soundproof generating set the lo cal remote selector must be in remote position to start the generating set using the in...

Страница 14: ...set except in emergencies and contact your Nanni Diesel authorised dealer Stopping the generating set Before stopping the generating set cut the power of the electrical appliances connected to the cr...

Страница 15: ...50 of pure antifreeze Use clean and distilled water for the mix Water that is too hard will produce limescale build up and will reduce the cooling system s effectiveness The cooling system allow the...

Страница 16: ...e generating set as they may increase the risk of fire in the engine compartment Check the operation of the different lamps and indica tors situated on the instrument panel Take care not to get the ge...

Страница 17: ...receptacle under the filter and then remove the used filter C cartridge Apply a thin layer of fuel over the seal surface of the new filter cartridge before fitting it Tighten it by hand until the fil...

Страница 18: ...urn Start the engine and let it warm up for approximately 5 minutes so that oil suction is easier Stop the engine Use a pail to collect the extracted oil and pump until the oil has been completely ext...

Страница 19: ...t must be drained in or der to remove the various deposits that can build up in the circuit Carry out this operation with the engine stopped and cold Place a receptacle under the drain cap then un tig...

Страница 20: ...d with fresh wa ter Ensure the receptacle you use is large enough as the seawater pump must never be run without water Check that no one is in the vicinity of the engine and then start it Let the engi...

Страница 21: ...p propriate grease If the battery is replaced use a battery with similar specifications to the previous one If starting with an emergency battery and connection cables proceed as follows Connect the e...

Страница 22: ...tec tion of the generating set and consequently the gener ating set itself The installer should ensure that all the necessary precautions are taken to guarantee the cor rosion protection of the genera...

Страница 23: ...ce the fuse or replace the circuit breaker Electrical circuit breaker is not working Electrical connections are faulty Check the electrical connections and wires especially the battery cables Clean an...

Страница 24: ...ck or faulty Re tighten or replace the belt Seawater pump rotor is faulty Replace the rotor Insufficient coolant Fill with coolant and check that the cooling system is leak tight Thermostat is malfunc...

Страница 25: ......

Страница 26: ...Nanni Industries S A S 11 Avenue Mariotte 33260 La Teste France Tel 33 0 5 56 22 30 60 Fax 33 0 5 56 22 30 79 www nannidiesel com...

Отзывы: