6-2-3-3 Sword Test
This item checks the sword movement within the sense area.
1.
Select “SWORD TEST” from the I/O menu screen. The following screen is
displayed.
2.
The screen will display the sword when the sword is placed in the sensor
area. Check that the sword is displayed in the relevant position.
* If “NOT WORKING” is displayed against either sensor, that number
sensor on either the left or right is malfunctioning. If this happens, the
angle of the sword displayed on the screen will be incorrect.
3.
If the sword displayed on the screen is noticeably in the wrong position,
check the sensor sensitivity.
(see 6-2-3-2 page 51)
If no problem with the
sensor sensitivity is found, make the adjustments detailed in the “SWORD
ADJUSTMENT” section
(see 6-2-3-4 page 53)
4.
Press the Enter switch to return to the I/O menu screen.
SENSOR1 WORKING
IN
SENSOR2 NOT WORKING
ENTER SW:EXIT