background image

1:3

ACID

6
7
8

9

6

7

8

9

TYPICAL SYSTEM INSTALLATION

NKD-pH uses a 1 : 3 Acid/Water mix ratio.  Add 15L water then 5L of acid to a 20L 

drum.  Always add acid to water, never water to acid.
Install the Clear Injection Tee Piece before or after the OXI & ION Cell Housing 

taking note of the flow direction indicator.  
All installations must be after any heating.
Store the acid drum at the furthest possible point away from all equipment.

Before you start:

Indicates direction of water flow

1
2
3
4
5

Naked Control Unit
OXI & ION Housing
Filter
Heater
Pool Pump

4

NKD-pH Controller
Clear Injection Tee Piece
Acid Drum with weighted 

Suction Valve and Label
Clear PVC Flexible Tube

It is important to understand a certain amount of owner maintenance and care is 

required to keep your investment operating properly. We recommend the following 

basic maintenance and further information can be found on the Naked Pools App.

4.1 Injection Point on Injector Valve

Check the injection point periodically by inspecting the Clear Injection Tee Piece for 

build-up of solid matter at the end of the PVC tubing. While unscrewing the BLACK 

lock nut, take care not to lose the rubber O-ring.

4.2 Lubricate Squeeze Tube

Lubricate the pump squeeze tube every 3-6 months. Use a silicone-based lubricant 

only as petroleum-based lubricants will cause damage to the tube and rollers.

4.3 Replace Squeeze Tube

Depending on usage, the squeeze tube may need replacement after 1-2 years of use. 

Before replacing, ensure that the suction and injection tubes are empty. To replace 

the squeeze tube, please follow the instructions included with the replacement kit, 

or on the Naked Pools App. 
Only use original sized commercial grade Tygon® Norprene® tube as incorrect sizing 

will result in early failure of the Tri Roller Block.

1

2

3

4

5

Содержание NKD-pH

Страница 1: ...ALLATION IMPROPER INSTALLATION WILL VOID WARRANTY PRODUCT ONLY TO BE INSTALLED SERVICED BY A SUITABLY QUALIFIED PROFESSIONAL THIS MANUAL CONTAINS IMPORTANT INFORMATION ONCE INSTALLATION IS COMPLETE IN...

Страница 2: ...ts There is a danger of electric shock if opened If the power cord is damaged then the manufacturer their agent or a similar qualified person in order to avoid a hazard should replace it The product s...

Страница 3: ...ad Screwdriver PVC Primer Glue Drill 6mm Drill Bit pH Controller with Wall Mount Bracket Clear Tee with Lock Nut Injector Valve c w Sleeve Tube Nut Injector O Ring Clear PVC Flexible Tube 6m Acid Drum...

Страница 4: ...the OXI ION Cell Housing taking note of the flow direction indicator All installations must be after any heating Store the acid drum at the furthest possible point away from all equipment Before you s...

Страница 5: ...tach to the Acid Drum with weighted Suction Valve Connect the Clear Flexible PVC Tube to the base of the peristaltic pump right side and attach to the Clear Injection Tee Piece Plug the pH Controller...

Страница 6: ...nt entered and once completed will return to the RUN TIME in pH1 Calculate the amount of acid required by using the Dosing Calculator in the Naked Pools App Simply select the ml required by pressing t...

Страница 7: ...Tube Heavy duty PVC Approved piggy back type 40 50mm 80 650 34 2 5 4 2 Lubricate Squeeze Tube Lubricate the pump squeeze tube every 3 6 months Use a silicone based lubricant only as petroleum based l...

Страница 8: ...Swimming as nature intended or visit your App Store and search Naked Pools 1800 625 331 support naked pools com www naked pools com SCAN THIS CODE T O G E T T H E NAKED APP...

Отзывы: